A complete 256-channel reconfigurable system for in vitro neurobiological experiments

被引:0
作者
Zoladz, Miroslaw [1 ]
Kmon, Piotr [1 ]
Rauza, Jacek [1 ]
Grybos, Pawel [1 ]
Kowalczyk, Tomasz [2 ]
Caban, Bartosz [2 ]
机构
[1] AGH Univ Sci & Technol, Fac Elect Engn Automat Comp Sci & Biomed Engn, Dept Measurement & Elect, Krakow, Poland
[2] Univ Lodz, Dept Neurobiol, Lodz, Poland
来源
2013 IEEE BIOMEDICAL CIRCUITS AND SYSTEMS CONFERENCE (BIOCAS) | 2013年
关键词
D O I
暂无
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
We present a complete reconfigurable measurement system for 256-channel in vitro recordings and electrical stimulation of brain tissue electrophysiological activity. The system is built of: brain tissue life support system, Microelectrode Array (MEA), 4 multichannel integrated electronic circuits for signals conditioning and electrical stimulation, Digitizer and PC Application for measurement, data presentation and storage. The life support system is responsible for keeping brain tissue samples in appropriately saturated artificial cerebrospinal fluid at a very stable temperature. We designed two versions of the ASIC's that can be easily adopted to the system. These are processed in the CMOS 180nm technology and differ with the main parameters that suits for different types of experiments. The ASIC's are dedicated to amplification, filtering, and electrical stimulation of the 256 channels while the Digitizer performs simultaneous data acquisition from 256 channels with 14 kS/s sample rate and 12bit resolution. The resulting byte stream is transmitted to PC via USB (Universal Serial Bus). We also show a neurobiological experiment results that confirm the system is able to keep the extracted brain tissue active (posterior hypothalamic slices) and to record local theta field potentials with very small amplitudes from multiple neurons simultaneously.
引用
收藏
页码:250 / 253
页数:4
相关论文
共 7 条
[1]   An in vitro model of a retinal prosthesis [J].
Ahuja, Ashish K. ;
Behrend, Matthew R. ;
Kuroda, Masako ;
Humayun, Mark S. ;
Weiland, James D. .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2008, 55 (06) :1744-1753
[2]  
Grybos P., 2002, MONOGRAPHY AGH UCZEL, V117
[3]   64 CHANNEL NEURAL RECORDING AMPLIFIER WITH TUNABLE BANDWIDTH IN 180 nm CMOS TECHNOLOGY [J].
Grybos, Pawel ;
Kmon, Piotr ;
Zoladz, Miroslaw ;
Szczygiel, Robert ;
Kachel, Maciej ;
Lewandowski, Marian ;
Blasiak, Tomasz .
METROLOGY AND MEASUREMENT SYSTEMS, 2011, 18 (04) :631-643
[4]   Reach and grasp by people with tetraplegia using a neurally controlled robotic arm [J].
Hochberg, Leigh R. ;
Bacher, Daniel ;
Jarosiewicz, Beata ;
Masse, Nicolas Y. ;
Simeral, John D. ;
Vogel, Joern ;
Haddadin, Sami ;
Liu, Jie ;
Cash, Sydney S. ;
van der Smagt, Patrick ;
Donoghue, John P. .
NATURE, 2012, 485 (7398) :372-U121
[5]  
Kmon P., 2013, IEEE T CIRCUITS SY 1
[6]  
Kowalczyk T., 2013, HIPPOCAMPUS, DOI [10.1002/hipo.22167, DOI 10.1002/HIP0.22167]
[7]   What does the eye tell the brain?: Development of a system for the large-scale recording of retinal output activity [J].
Litke, AM ;
Bezayiff, N ;
Chichilnisky, EJ ;
Cunningham, W ;
Dabrowski, W ;
Grillo, AA ;
Grivich, M ;
Grybos, P ;
Hottowy, P ;
Kachiguine, S ;
Kalmar, RS ;
Mathieson, K ;
Petrusca, D ;
Rahman, A ;
Sher, A .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2004, 51 (04) :1434-1440