Automatic detection system for multiple region of interest registration to account for posture changes in head and neck radiotherapy

被引:7
作者
Mencarelli, A. [1 ]
van Beek, S. [1 ]
Zijp, L. J. [1 ]
Rasch, C. [1 ]
van Herk, M. [1 ]
Sonke, J-J [1 ]
机构
[1] Netherlands Canc Inst, Dept Radiat Oncol, NL-1066 CX Amsterdam, Netherlands
关键词
automatic segmentation; H and N cancer; image guided radiotherapy; SETUP UNCERTAINTIES; AUTO-SEGMENTATION; CANCER-PATIENTS; CT IMAGES;
D O I
10.1088/0031-9155/59/8/2005
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Despite immobilization of head and neck (H and N) cancer patients, considerable posture changes occur over the course of radiotherapy (RT). To account for the posture changes, we previously implemented a multiple regions of interest (mROIs) registration system tailored to the H and N region for image-guided RT correction strategies. This paper is focused on the automatic segmentation of the ROIs in the H and N region. We developed a fast and robust automatic detection system suitable for an online image-guided application and quantified its performance. The system was developed to segment nine high contrast structures from the planning CT including cervical vertebrae, mandible, hyoid, manubrium of sternum, larynx and occipital bone. It generates nine 3D rectangular-shaped ROIs and informs the user in case of ambiguities. Two observers evaluated the robustness of the segmentation on 188 H and N cancer patients. Bland-Altman analysis was applied to a sub-group of 50 patients to compare the registration results using only the automatically generated ROIs and those manually set by two independent experts. Finally the time performance and workload were evaluated. Automatic detection of individual anatomical ROIs had a success rate of 97%/53% with/without user notifications respectively. Following the notifications, for 38% of the patients one or more structures were manually adjusted. The processing time was on average 5 s. The limits of agreement between the local registrations of manually and automatically set ROIs was comprised between +/- 1.4 mm, except for the manubrium of sternum (-1.71 mm and 1.67 mm), and were similar to the limits agreement between the two experts. The workload to place the nine ROIs was reduced from 141 s (+/- 20 s) by the manual procedure to 59 s (+/- 17 s) using the automatic method. An efficient detection system to segment multiple ROIs was developed for Cone-Beam CT image-guided applications in the H and N region and is clinically implemented in our department.
引用
收藏
页码:2005 / 2021
页数:17
相关论文
共 20 条
  • [1] RANDOM POSITIONAL VARIATION AMONG THE SKULL, MANDIBLE, AND CERVICAL SPINE WITH TREATMENT PROGRESSION DURING HEAD-AND-NECK RADIOTHERAPY
    Ahn, Peter H.
    Ahn, Andrew I.
    Lee, C. Joe
    Shen, Jin
    Miller, Ekeni
    Lukaj, Alex
    Milan, Elissa
    Yaparpalvi, Ravindra
    Kalnicki, Shaloni
    Garg, Madhur K.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2009, 73 (02): : 626 - 633
  • [2] STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
    BLAND, JM
    ALTMAN, DG
    [J]. LANCET, 1986, 1 (8476) : 307 - 310
  • [3] CONNECTIONISM, COMPETENCE, AND EXPLANATION
    CLARK, A
    [J]. BRITISH JOURNAL FOR THE PHILOSOPHY OF SCIENCE, 1990, 41 (02) : 195 - 222
  • [4] Cover T M, 1991, ELEMENTS INFORM THEO, P82
  • [5] Ghahramani Z, 2004, LECT NOTES ARTIF INT, V3176, P72
  • [6] Factorial hidden Markov models
    Ghahramani, Z
    Jordan, MI
    [J]. MACHINE LEARNING, 1997, 29 (2-3) : 245 - 273
  • [7] Han X, 2010, MED IMAGE ANAL CLIN, P297
  • [8] Han X, 2008, LECT NOTES COMPUT SC, V5242, P434
  • [9] A formal analysis of why heuristic functions work
    Oommen, BJ
    Rueda, LG
    [J]. ARTIFICIAL INTELLIGENCE, 2005, 164 (1-2) : 1 - 22
  • [10] Auto-segmentation of normal and target structures in head and neck CT images: A feature-driven model-based approach
    Qazi, Arish A.
    Pekar, Vladimir
    Kim, John
    Xie, Jason
    Breen, Stephen L.
    Jaffray, David A.
    [J]. MEDICAL PHYSICS, 2011, 38 (11) : 6160 - 6170