A flow-based procedure with solenoid micro-pumps for the spectrophotometric determination of uric acid in urine

被引:81
作者
Rocha, Diogo L. [1 ]
Rocha, Fabio R. P. [1 ]
机构
[1] Univ Sao Paulo, Inst Quim, BR-05599970 Sao Paulo, Brazil
基金
巴西圣保罗研究基金会;
关键词
Multicommutation; Flow analysis; Clinical analysis; Urine; Uric acid; SYSTEM; INSTRUMENTATION; CYCLAMATE; ELECTRODE; SERUM;
D O I
10.1016/j.microc.2009.08.010
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The determination of uric acid in urine shows clinical importance, once it can be related to human organism dysfunctions, such as gout. An analytical procedure employing a multicommuted flow system was developed for the determination of uric acid in urine samples. Cu(II) ions are reduced by uric acid to Cu(I) that can be quantified by spectrophotometry in the presence of 2,2'-biquinoline 4,4'-dicarboxylic acid (BCA). The analytical response was linear between 10 and 100 mu mol L-1 uric acid with a detection limit of 3.0 mu mol L-1 (99.7% confidence level). Coefficient of variation of 1.2% and sampling rate of 150 determinations per hour were achieved. Per determination, 32 mu g of CuSO4 and 200 mu g of BCA were consumed, generating 2.0 mL of waste. Recoveries from 91 to 112% were estimated and the results for 7 urine samples agreed with those obtained by the commercially available enzymatic kit for determination of uric acid. The procedure required 100-fold dilution of urine samples, minimizing sample consumption and interfering effects. In order to avoid the manual dilution step, on-line sample dilution was achieved by a simple system reconfiguration attaining a sampling rate of 95 h(-1). (C) 2009 Elsevier B.V. All rights reserved.
引用
收藏
页码:53 / 59
页数:7
相关论文
共 38 条
[1]  
[Anonymous], 2002, Oxidative Phosphorylation
[2]   Kinetic determination of uric acid in urine based on single-line flow-system with multi-site detection [J].
Araujo, AN ;
Catita, JAM ;
Lima, JLFC .
ANALYTICAL SCIENCES, 1998, 14 (04) :809-813
[3]  
Bishop M., 2005, Clinical Chemistry Principles, Procedures, Correlations, V5th
[4]   A QUANTITATIVE TEST FOR COPPER USING BICINCHONINIC ACID [J].
BRENNER, AJ ;
HARRIS, ED .
ANALYTICAL BIOCHEMISTRY, 1995, 226 (01) :80-84
[5]   A critical comparison of analytical flow systems exploiting streamlined and pulsed flows [J].
Dias, Ana C. B. ;
Santos, Joao L. M. ;
Lima, Jose L. F. C. ;
Quintella, Cristina M. ;
Lima, Angelo M. V. ;
Zagatto, Elias A. G. .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2007, 388 (5-6) :1303-1310
[6]  
DUTT V V S E, 1974, Analytical Chemistry, V46, P1777, DOI 10.1021/ac60348a041
[7]   DIRECT DETERMINATION OF URIC ACID USING URICASE [J].
FEICHTMEIR, TV ;
WRENN, HT .
AMERICAN JOURNAL OF CLINICAL PATHOLOGY, 1955, 25 (07) :833-839
[8]  
FOSSATI P, 1980, CLIN CHEM, V26, P227
[9]  
GARCIA MBQ, 2004, PORT ELECTROCHIM ACT, V22, P249
[10]   NOVEL, REAGENTLESS, AMPEROMETRIC BIOSENSOR FOR URIC-ACID BASED ON A CHEMICALLY-MODIFIED SCREEN-PRINTED CARBON ELECTRODE COATED WITH CELLULOSE-ACETATE AND URICASE [J].
GILMARTIN, MAT ;
HART, JP .
ANALYST, 1994, 119 (05) :833-840