CdZnTe detectors for small field of view positron emission tomographic imaging

被引:25
作者
Drezet, Arnaud [1 ]
Monnet, Olivier [1 ]
Mathy, Francoise [1 ]
Montemont, Guillaume [1 ]
Verger, Loick [1 ]
机构
[1] CEA, LETI, MINATEC, F-38054 Grenoble, France
关键词
CdZnTe; positron emission tomography; timing resolution; depth of interaction measurement;
D O I
10.1016/j.nima.2006.10.292
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
We report the timing performance between two 16 x 20 X 0.9 mm(3) cadmium zinc telluride (CZT) detectors equipped with a specific orthogonal electrode geometry (16 anodes and 5 cathodes with 1 and 4 mm pitch, respectively) and a dedicated electronic setup for Positron Emission Tomography (PET) application. The measured coincidence times reach 2.6 ns full-width at half-maximum (FWHM) for a 500 V bias voltage and 300 keV energy threshold. Subsequently, a simulation study was carried out to assess the spatial and efficiency performances of these detectors, which allow the depth of interaction (DOT) measurement and so limit the parallax error. Preliminary results show that the proposed design could reach a better homogeneity of the spatial resolution across the field of view than what is achieved with the standard PET scintillation. (c) 2006 Elsevier B.V. All rights reserved.
引用
收藏
页码:465 / 470
页数:6
相关论文
共 19 条
[1]   Timing performance of pixelated CdZnTe detectors [J].
Amrami, R ;
Shani, G ;
Hefetz, Y ;
Pansky, A ;
Wainer, N .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2001, 458 (03) :772-781
[2]   TIMING RESPONSE OF CDTE DETECTORS [J].
BALDAZZI, G ;
BOLLINI, D ;
CASALI, F ;
CHIRCO, P ;
DONATI, A ;
DUSI, W ;
LANDINI, G ;
ROSSI, M ;
STEPHEN, JB .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1993, 326 (1-2) :319-324
[3]   PENELOPE - AN ALGORITHM FOR MONTE-CARLO SIMULATION OF THE PENETRATION AND ENERGY-LOSS OF ELECTRONS AND POSITRONS IN MATTER [J].
BARO, J ;
SEMPAU, J ;
FERNANDEZVAREA, JM ;
SALVAT, F .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 1995, 100 (01) :31-46
[4]   Timing properties of CdZnTe detectors for positron emission tomography [J].
Bertolucci, E ;
Conti, M ;
Curto, CA ;
Russo, P .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1997, 400 (01) :107-112
[5]   CHARACTERIZATION OF SMALL CDTE DETECTORS TO BE USED FOR LINEAR AND MATRIX ARRAYS [J].
CASALI, F ;
BOLLINI, D ;
CHIRCO, P ;
ROSSI, M ;
BALDAZZI, G ;
DUSI, W ;
CAROLI, E ;
DICOCCO, G ;
DONATI, A ;
LANDINI, G ;
STEPHEN, JB .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1992, 39 (04) :598-604
[6]   PROPERTIES OF A NEW CDTE DETECTOR FOR NUCLEAR-MEDICINE [J].
FREDERICK, E ;
CLAPP, A ;
ENTINE, G ;
HAZLETT, T ;
LUND, JC ;
SINCLAIR, F ;
SQUILLANTE, MR .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1987, 34 (01) :354-358
[7]   Large dynamic range 64-channel ASIC for CZT or CdTe detectors [J].
Glasser, F ;
Villard, P ;
Rostaing, JP ;
Accensi, M ;
Baffert, N ;
Girard, JL .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2003, 509 (1-3) :183-190
[8]   CdZnTe high-energy radiography detector [J].
Glasser, F ;
Gerbe, V ;
Ouvrier-Buffet, P ;
Accensi, M ;
Girard, JL ;
Renaud, M ;
Gersten-mayer, JL .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2001, 458 (1-2) :544-550
[9]  
HICHWA R, 1994, J NUCL MED, V35, P1396
[10]  
LAMMERTSMA AA, 1995, J NUCL MED, V36, P2391