A comparative study of brain perfusion single-photon emission computed tomography and magnetic resonance imaging in patients with post-traumatic anosmia

被引:23
|
作者
Atighechi, Saeid [1 ]
Salari, Hadi
Baradarantar, Mohammad Hossein [1 ]
Jafari, Rozita [1 ]
Karimi, Ghasem [1 ]
Mirjali, Mehdi [2 ]
机构
[1] Yazd Univ Med Sci, Shahid Sadughi Hosp, Dept Otolaryngol, Shahid Ghandi 8915887857, Yazd, Iran
[2] Forens Med Org Yazd, Yazd, Iran
关键词
Anosmia; frontal lobe; head injury; MRI; 99mtc-ethyl-cysteinate-dimer; olfactory bulb; SPECT; CLOSED HEAD-INJURY; OLFACTORY FUNCTION; COMPARING SPECT; SMELL; DYSFUNCTION; TASTE; MRI;
D O I
10.2500/ajra.2009.23.3345
中图分类号
R76 [耳鼻咽喉科学];
学科分类号
100213 ;
摘要
Background: Loss of smell is a problem that can occur in up to 30% of patients with head trauna. The olfactory function investigation methods so far in use have mostly relied on subjective responses given by patients. Recently, some studies have used magnetic resonance imaging (MRI) and single-photon emission computed tomography (SPECT) to evaluate patients with post-traumatic anosmia. The present study seeks to detect post-traumatic anosmia and the areas in the brain that are related to olfactory impairment by using SPECT and MRI as imaging techniques. Methods: The study was conducted on 21 patients suffering from head injury and consequently anosmia as defined by an olfactory identification test. Two control groups (traumatic normosmic and nontraumatic healthy individuals) were selected. Brain MRI, qualitative and semiquantitative SPECT with 99mtc-ethyl-cysteinate-dimer were taken from all the patients. Then the brain SPECT and MRI were compared with each other. Results: Semi-quantitative assessment of the brain perfusion SPECT revealed frontal, left parietal, and left temporal hypoperfusion as compared with the two control groups. Eighty-five percent of the anosmic patients had abnormal brain MRI. Regarding the MRI, the main abnormality proved to be in the anterior inferior region of the frontal lobes and olfactory bulbs. Conclusions: The findings of this study suggest that damage to the frontal lobes and olfactory bulbs as shown in the brain MRI and hypoperfusion in the frontal, left parietal, and left temporal lobes in the semiquantitative SPECT corresponds to post-traumatic anosmia. Further neurophysiological and imaging studies are definitely needed to set the idea completely. (Am J Rhinol Allergy 23, 409-412, 2009; doi: 10.2500/ajra.2009.23.3345)
引用
收藏
页码:409 / 412
页数:4
相关论文
共 50 条
  • [31] The usefulness of combined brain perfusion single-photon emission computed tomography, Dopamine-transporter single-photon emission computed tomography, and 123I-metaiodobenzylguanidine myocardial scintigraphy for the diagnosis of dementia with Lewy bodies
    Kobayashi, Seiju
    Makino, Kanae
    Hatakeyama, Shigeki
    Ishii, Takao
    Tateno, Masaru
    Iwamoto, Tomo
    Tsujino, Hanako
    Kawasaki, Kazuhito
    Mikuni, Kouhei
    Ukai, Wataru
    Murayama, Tomonori
    Hashimoto, Eri
    Utsumi, Kumiko
    Kawanishi, Chiaki
    PSYCHOGERIATRICS, 2017, 17 (04) : 247 - 255
  • [32] Pilot study for comparative assessment of dual-energy computed tomography and single-photon emission computed tomography V/Q scanning for lung perfusion evaluation in infants
    Ramirez-Suarez, Karen, I
    Barrera, Christian A.
    Otero, Hansel J.
    Biko, David M.
    States, Lisa J.
    Servaes, Sabah
    Zhu, Xiaowei
    Davis, James C.
    Piccione, Joseph
    Rapp, Jordan B.
    PEDIATRIC PULMONOLOGY, 2022, 57 (03) : 702 - 710
  • [33] Which is the optimal threshold for defining functional lung in single-photon emission computed tomography lung perfusion imaging of lung cancer patients?
    Ding, Xiuping
    Man, Xianfeng
    Sun, Mingping
    Xing, Jun
    Fan, Tingyong
    Gao, Min
    Yan, Hongjiang
    Li, Baosheng
    NUCLEAR MEDICINE COMMUNICATIONS, 2018, 39 (02) : 103 - 109
  • [34] Magnetic resonance imaging as an alternative to computed tomography in select patients with traumatic brain injury: a retrospective comparison
    Roguski, Marie
    Morel, Brent
    Sweeney, Megan
    Talan, Jordan
    Rideout, Leslie
    Riesenburger, Ron I.
    Madan, Neel
    Hwang, Steven
    Journal of Neurosurgery-Pediatrics, 2015, 15 (05) : 529 - 534
  • [35] Incidence of a single subsegmental mismatched perfusion defect in single-photon emission computed tomography and planar ventilation/perfusion scans
    Stubbs, Matthew
    Chan, Kenneth
    McMeekin, Helena
    Navalkissoor, Shaunak
    Wagner, Thomas
    NUCLEAR MEDICINE COMMUNICATIONS, 2017, 38 (02) : 135 - 140
  • [36] Correlation of magnetic resonance imaging findings with hexamethylpropyleneamine oxime brain single photon emission computed tomography in ischemic stroke patients in the subacute stage
    Kiresi, D
    Tastekin, G
    Cengiz, SL
    Üstun, ME
    Yürüten, B
    ACTA RADIOLOGICA, 2006, 47 (04) : 401 - 407
  • [37] Cardiac motion correction with a deep learning network for perfusion defect assessment in single-photon emission computed tomography myocardial perfusion imaging
    Zhang, Xirang
    Yang, Yongyi
    Pretorius, P. Hendrik
    Slomka, Piotr J.
    King, Michael A.
    JOURNAL OF NUCLEAR CARDIOLOGY, 2025, 43
  • [38] Does location matter? Prognostic value of single-photon emission computed tomography myocardial perfusion imaging by vascular territory
    Slim, Hanna B.
    Nair, Sanjeev U.
    Arora, Sabeena
    Heller, Gary V.
    JOURNAL OF NUCLEAR CARDIOLOGY, 2012, 19 (03) : 458 - 464
  • [39] Does location matter? Prognostic value of single-photon emission computed tomography myocardial perfusion imaging by vascular territory
    Hanna B. Slim
    Sanjeev U. Nair
    Sabeena Arora
    Gary V. Heller
    Journal of Nuclear Cardiology, 2012, 19 : 458 - 464
  • [40] Diagnostic value of ventilation/perfusion single-photon emission computed tomography/computed tomography for bronchiolitis obliterans syndrome in patients after lung transplantation
    Nakashima, Masahiro
    Shinya, Takayoshi
    Oto, Takahiro
    Okawa, Tomoyo
    Takeda, Yoshihiro
    NUCLEAR MEDICINE COMMUNICATIONS, 2019, 40 (07) : 703 - 710