Possibilities and limitations of current stereo-endoscopy

被引:29
作者
Mueller-Richter, UDA
Limberger, A
Weber, P
Ruprecht, KW
Spitzer, W
Schilling, M
机构
[1] Univ Saarland, Dept Oral & Maxillofacial Surg, D-66421 Homburg, Germany
[2] Univ Saarland, Dept Gen Surg, D-66421 Homburg, Germany
[3] Fraunhofer Inst Biomed Engn IBMT, D-66386 St Ingbert, Germany
[4] Univ Saarland, Dept Ophthalmol, D-66421 Homburg, Germany
来源
SURGICAL ENDOSCOPY AND OTHER INTERVENTIONAL TECHNIQUES | 2004年 / 18卷 / 06期
关键词
stereoendoscopy; autostereoscopic display; spatial vision; endoscopy; laparoscopic;
D O I
10.1007/s00464-003-9097-6
中图分类号
R61 [外科手术学];
学科分类号
摘要
Background: Stereo-endoscopy has become a commonly used technology. In many comparative studies striking advantages of stereo-endoscopy over two-dimensional presentation could not be proven. To show the potential and fields for further improvement of this technology is the aim of this article. Method: The physiological basis of three-dimensional vision limitations of current stereo-endoscopes is discussed and fields for further research are indicated. New developments in spatial picture acquisition and spatial picture presentation are discussed. Results: Current limitations of stereo-endoscopy that prevent a better ranking in comparative studies with two-dimensional presentation are mainly based on insufficient picture acquisition. Conclusion: Devices for three-dimensional picture presentation are at a more advanced developmental stage than devices for three-dimensional picture acquisition. Further research should emphasize the development of new devices for three-dimensional picture acquisition.
引用
收藏
页码:942 / 947
页数:6
相关论文
共 51 条
[1]  
Arezzo A, 2000, Chir Ital, V52, P451
[2]  
BECKAGE NE, 1993, RECEPTOR, V3, P233
[3]  
BIRKETT DH, 1994, SURG ENDOSC-ULTRAS, V8, P1448
[4]   PRELIMINARY EVALUATION OF THE PROTOTYPE STEREOSCOPIC ENDOSCOPE - PRECISE 3-DIMENSIONAL MEASUREMENT SYSTEM [J].
CATALANO, MF ;
VANDAM, J ;
BEDFORD, R ;
COTHREN, RM ;
SIVAK, MV .
GASTROINTESTINAL ENDOSCOPY, 1993, 39 (01) :23-28
[5]   Comparison of two-dimensional vs three-dimensional camera systems in laparoscopic surgery [J].
Chan, ACW ;
Chung, SCS ;
Yim, APC ;
Lau, JYW ;
Ng, EKW ;
Li, AKC .
SURGICAL ENDOSCOPY-ULTRASOUND AND INTERVENTIONAL TECHNIQUES, 1997, 11 (05) :438-440
[6]   Evaluation of a head-mounted display (HMD) in the performance of a simulated laparoscopic task [J].
Cheah, WK ;
Lenzi, JE ;
So, J ;
Dong, F ;
Kum, CK ;
Goh, P .
SURGICAL ENDOSCOPY-ULTRASOUND AND INTERVENTIONAL TECHNIQUES, 2001, 15 (09) :990-991
[7]   Newly developing endoscopic devices - Shadow optics and micromachine [J].
Chee, YJ ;
Lee, SW ;
Park, K .
YONSEI MEDICAL JOURNAL, 1999, 40 (06) :550-553
[8]   COMPARISON OF DIRECT VISION AND ELECTRONIC 2-DIMENSIONAL AND 3-DIMENSIONAL DISPLAY SYSTEMS ON SURGICAL TASK EFFICIENCY IN ENDOSCOPIC SURGERY [J].
CROSTHWAITE, G ;
CHUNG, T ;
DUNKLEY, P ;
SHIMI, S ;
CUSCHIERI, A .
BRITISH JOURNAL OF SURGERY, 1995, 82 (06) :849-851
[9]   MINIMAL ACCESS SURGERY AND THE FUTURE OF INTERVENTIONAL LAPAROSCOPY [J].
CUSCHIERI, A .
AMERICAN JOURNAL OF SURGERY, 1991, 161 (03) :404-407
[10]   Visual integration of data and basic motor skills under laparoscopy - Influence of 2-D and 3-D video-camera systems [J].
Dion, YM ;
Gaillard, F .
SURGICAL ENDOSCOPY-ULTRASOUND AND INTERVENTIONAL TECHNIQUES, 1997, 11 (10) :995-1000