An empirical study of modified beat SQI based majority voting fusion method for heart-rate estimation in noisy multimodal cardiovascular signals

被引:0
作者
Rankawat, Shalini A. [1 ]
机构
[1] Govt Engn Coll, Dept Instrumentat & Control, Gandhinagar, India
关键词
multimodal physiological signalnoisy cardiovascular signals; ECG detectors; heart rate; arterial blood pressure; modified beat SQI-based majority voting fusion method; non-cardiovascular signals; ALGORITHM;
D O I
10.1088/1361-6579/ac9bc8
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Objectives. Most existing heartbeat-detection algorithms rely heavily on cardiovascular signals, namely electrocardiogram (ECG) and arterial blood pressure (ABP), which are often corrupted by noise, leading to unreliable heart-rate estimates. Simultaneously recorded non-cardiovascular (NC) signals help with reliable heart-rate estimates when both cardiovascular signals are corrupted by noise. This study aims to: (i) propose a modified beat signal quality index-based majority voting fusion (MMVF) method to deal with extremely noisy cardiovascular signals; (ii) generate synthetic noise datasets from standard PhysioNet datasets by adding different types of ECG noises, i.e. baseline wander (bw), electrode motion (em), muscle artifact (ma), and realistic artificial ABP noises in clean or low-noise ECG and ABP signals, respectively; and (iii) analyze the effectiveness of the MMVF method for heart-rate estimation with different combinations of beat detectors. Approach. The modified beat signal quality index in the proposed method can identify the quality of the signal even when it contains long durations of noise. The MMVF method assigns uniform weights to the beats detected from all multimodal physiological signals, thus enabling effective participation of beats from NC signals when both cardiovascular signals are corrupted. Results. Fusion of the NC signals with noisy cardiovascular signals using the MMVF method improves heart-rate estimation accuracy over that of single ECG beat detectors like gqrs, epltd, and slope sum function and Teager-Kaiser energy (SSF-TKE) up to 98.81%, 97.95%, and 87.98%, respectively. This method has yielded robust heart-rate estimation within clinically acceptable error limits in concurrently highly noisy cardiovascular signals (ECG: up to a signal-to-noise ratio (SNR) of -70 dB and ABP: up to 100% noise duration in noisy segments) by their fusion with NC signals. Significance. This study serves as empirical evidence for the robustness of the MMVF method in scenarios where there are extremely noisy cardiovascular signals and NC signals with ECG R-peak artifacts.
引用
收藏
页数:22
相关论文
共 22 条
  • [1] Abromavicius V., 2015, ALGORITHM REAL TIME, P1, DOI [10.1109/eStream.2015.7119478, DOI 10.1109/ESTREAM.2015.7119478]
  • [2] [Anonymous], 2002, EC13 ANSI AAMI, P1
  • [3] Borges GD, 2014, IEEE IMTC P, P1310, DOI 10.1109/I2MTC.2014.6860957
  • [4] A COMPARISON OF THE NOISE SENSITIVITY OF 9 QRS DETECTION ALGORITHMS
    FRIESEN, GM
    JANNETT, TC
    JADALLAH, MA
    YATES, SL
    QUINT, SR
    NAGLE, HT
    [J]. IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1990, 37 (01) : 85 - 98
  • [5] RS slope detection algorithm for extraction of heart rate from noisy, multimodal recordings
    Gieraltowski, Jan
    Ciuchcinski, Kamil
    Grzegorczyk, Iga
    Kosna, Katarzyna
    Solinski, Mateusz
    Podziemski, Piotr
    [J]. PHYSIOLOGICAL MEASUREMENT, 2015, 36 (08) : 1743 - 1761
  • [6] PhysioBank, PhysioToolkit, and PhysioNet - Components of a new research resource for complex physiologic signals
    Goldberger, AL
    Amaral, LAN
    Glass, L
    Hausdorff, JM
    Ivanov, PC
    Mark, RG
    Mietus, JE
    Moody, GB
    Peng, CK
    Stanley, HE
    [J]. CIRCULATION, 2000, 101 (23) : E215 - E220
  • [7] A Robust Method to Estimate Instantaneous Heart Rate from Noisy Electrocardiogram Waveforms
    Gribok, Andrei V.
    Chen, Xiaoxiao
    Reifman, Jaques
    [J]. ANNALS OF BIOMEDICAL ENGINEERING, 2011, 39 (02) : 824 - 834
  • [8] Open source ECG analysis
    Hamilton, P
    [J]. COMPUTERS IN CARDIOLOGY 2002, VOL 29, 2002, 29 : 101 - 104
  • [9] Development of the polysomnographic database on CD-ROM
    Ichimaru, Y
    Moody, GB
    [J]. PSYCHIATRY AND CLINICAL NEUROSCIENCES, 1999, 53 (02) : 175 - 177
  • [10] Robust heart rate estimation from multiple asynchronous noisy sources using signal quality indices and a Kalman filter
    Li, Q.
    Mark, R. G.
    Clifford, G. D.
    [J]. PHYSIOLOGICAL MEASUREMENT, 2008, 29 (01) : 15 - 32