Roentgen single-plane photogrammetric analysis (RSPA) - A new approach to the study of musculoskeletal movement

被引:17
作者
Yuan, X
Ryd, L [1 ]
Tanner, KE
Lidgren, L
机构
[1] Linkoping Univ Hosp, Dept Orthopaed, S-58185 Linkoping, Sweden
[2] Univ Lund Hosp, S-22185 Lund, Sweden
来源
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME | 2002年 / 84B卷 / 06期
关键词
D O I
10.1302/0301-620X.84B6.11146
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
We present a new approach for the accurate reconstruction of three-dimensional skeletal positions using roentgen single-plane photogrammetric analysis (RSPA). This technique uses a minimum of three markers embedded in each segment which allow continuous, real-time, internal skeletal movement to be measured from single-plane images, provided that the precise distance between the markers is known. A simulation study indicated that the error propagation in this approach is influenced by focus position, object position, the number of control points, the accuracy of the previous measurement of the distance between markers and the accuracy of image measurement. For reconstruction of normal movement of the knee with an input measurement error Of SD = 0.02 mm, the rotational and translational differences between reconstructed and original movement were less than 0.27degrees and 0.9 mm, respectively. Our results showed that the accuracy of RSPA is sufficient for the analysis of most movement of joints. This approach can be applied in combination with force measurements for dynamic studies of the musculoskeletal system.
引用
收藏
页码:908 / 914
页数:7
相关论文
共 24 条
[1]  
[Anonymous], THESIS U STRATHCLYDE
[2]   Accurate measurement of three-dimensional knee replacement kinematics using single-plane fluoroscopy [J].
Banks, SA ;
Hodge, WA .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1996, 43 (06) :638-649
[3]  
BORLIN N, 1997, 43 ANN T ORS M
[4]  
FLYNN M, 1996, MED IM S
[5]   A COMPUTER-BASED BIOMECHANICAL ANALYSIS OF THE 3-DIMENSIONAL MOTION OF CEMENTLESS HIP PROSTHESES [J].
GILBERT, JL ;
BLOOMFELD, RS ;
LAUTENSCHLAGER, EP ;
WIXSON, RL .
JOURNAL OF BIOMECHANICS, 1992, 25 (04) :329-340
[6]  
Gill H S, 1998, J BIOMECH, V31, P88
[7]   Three-dimensional determination of femoral-tibial contact positions under in vivo conditions using fluoroscopy [J].
Hoff, WA ;
Komistek, RD ;
Dennis, DA ;
Gabriel, SM ;
Walker, SA .
CLINICAL BIOMECHANICS, 1998, 13 (07) :455-472
[8]   ACTIVE KNEE MOTION AFTER CRUCIATE LIGAMENT RUPTURE - STEREORADIOGRAPHY [J].
KARRHOLM, J ;
SELVIK, G ;
ELMQVIST, LG ;
HANSSON, LI .
ACTA ORTHOPAEDICA SCANDINAVICA, 1988, 59 (02) :158-164
[9]   ROENTGEN STEREOPHOTOGRAMMETRY - REVIEW OF ORTHOPEDIC APPLICATIONS [J].
KARRHOLM, J .
ACTA ORTHOPAEDICA SCANDINAVICA, 1989, 60 (04) :491-503
[10]   INVIVO TRACKING OF THE HUMAN PATELLA [J].
KOH, TJ ;
GRABINER, MD ;
DESWART, RJ .
JOURNAL OF BIOMECHANICS, 1992, 25 (06) :637-&