Measurements of hindlimb blood flow recorded using Doppler ultrasound during administration of vasoactive agents in halothane-anesthetized horses

被引:18
作者
Raisis, AL
Young, LE
Meire, HB
Taylor, PM
Blissitt, KJ
Marlin, D
Lekeux, P
机构
[1] Ctr Equine Studies, Anim Hlth Trust, Newmarket CB8 7UU, Suffolk, England
[2] Kings Coll Hosp London, Dept Radiol, London SE5 9RS, England
[3] Univ Cambridge, Dept Clin Vet Med, Cambridge CB3 0ES, England
[4] Univ Edinburgh, Royal Dick Sch Vet Studies, Easterbush Vet Ctr, Dept Vet Clin Studies, Edinburgh EH25 9RG, Midlothian, Scotland
关键词
equine; anesthesia; Doppler ultrasound; blood flow; waveform analysis; phenylephrine; sodium nitroprusside;
D O I
10.1111/j.1740-8261.2000.tb00429.x
中图分类号
S85 [动物医学(兽医学)];
学科分类号
0906 ;
摘要
The purpose of the study was to determine the ability of Doppler ultrasound to detect changes in femoral blood flow during pharmacologic manipulation of arterial blood pressure. Doppler ultrasonography was performed in the femoral vessels of six halothane-anesthetized horses before and during administration of phenylephrine HCl and sodium nitroprusside. The time-averaged mean velocity and volumetric flow were calculated. The contour of the velocity waveform was assessed, and the early diastolic deceleration slope (EDDS) and pulsatility index (PI) were calculated. Administration of phenylephrine HCl resulted in increased mean aortic blood pressure (MABP) by 40% (29.3-53.0%). This caused significant decrease in cardiac output (26.8 to 13.5 l/min), femoral arterial velocity (left artery 7.20 to 4.00 cm/s; right artery 5.01 to 3.39 cm/s) and volumetric flow (left artery 556 to 221 ml/min; right artery 397 to 193 ml/min) in the femoral vessels and significant increase in systemic vascular resistance (163 to 433 dyn-s/cm(5)), EDDS (la: 285 to 468: ra: 250 to 481) and PI (la: 9.38 to 20.4; ra 17.1 to 29.1), Administration of sodium nitroprusside resulted in a decreased MABP of 27.2% (22.5-33%), This increased cardiac output (20.8 to 32.4 L/min), however, no significant changes were observed in femoral blood flow. Despite obvious changes in the waveform contour, no significant change occurred in EDDS or PI. These results suggest that Doppler ultrasound may be useful for measuring femoral blood flow in anesthetized horses. However, waveform analysis appears to be limited when multiple changes occur in central and peripheral haemodynamics.
引用
收藏
页码:64 / 72
页数:9
相关论文
共 32 条
  • [1] Abrams Jonathan, 1996, American Journal of Cardiology, V77, p31C, DOI 10.1016/S0002-9149(96)00186-5
  • [2] EVALUATION OF CHANGES IN SKELETAL-MUSCLE BLOOD-FLOW IN THE DOG WITH CONTRAST ULTRASONOGRAPHY
    ARONSON, S
    WALKER, R
    WIENCEK, JG
    ZAROFF, JG
    FEINSTEIN, SB
    ZACHARY, L
    [J]. PLASTIC AND RECONSTRUCTIVE SURGERY, 1995, 95 (01) : 114 - 118
  • [3] CARDIOVASCULAR EFFECTS OF SOME COMMONLY USED PRESSOR AMINES
    AVIADO, DM
    [J]. ANESTHESIOLOGY, 1959, 20 (01) : 71 - 97
  • [4] Effects of vasoactive medications on the blood flow of island musculocutaneous flaps in swine
    Cordeiro, PG
    Santamaria, E
    Hu, QY
    Heerdt, P
    [J]. ANNALS OF PLASTIC SURGERY, 1997, 39 (05) : 524 - 531
  • [5] IN-VIVO CORRELATION OF DOPPLER WAVE-FORM ANALYSIS WITH ARTERIAL INPUT IMPEDANCE PARAMETERS
    DOWNING, GJ
    MAULIK, D
    PHILLIPS, C
    KADADO, TR
    [J]. ULTRASOUND IN MEDICINE AND BIOLOGY, 1993, 19 (07) : 549 - 559
  • [6] Evans D. H., 1989, DOPPLER ULTRASOUND P
  • [8] GRANDY JL, 1987, AM J VET RES, V48, P192
  • [9] HEMODYNAMIC EFFECTS OF NEOSYNEPHRINE
    HORVATH, SM
    KNAPP, DW
    [J]. AMERICAN JOURNAL OF PHYSIOLOGY, 1954, 178 (03): : 387 - 391
  • [10] LAWSON NW, 1994, CLIN ANAESTHESIOL VA, V8, P1