Carotid Artery Lumen Segmentation in 3D Free-Hand Ultrasound Images Using Surface Graph Cuts

被引:0
|
作者
Lorza, Andres M. Arias [1 ]
Carvalho, Diego D. B. [1 ]
Petersen, Jens [2 ]
van Dijk, Anouk C. [3 ]
van der Lugt, Aad [3 ]
Niessen, Wiro J. [1 ,4 ]
Klein, Stefan [1 ]
de Bruijne, Marleen [1 ,2 ]
机构
[1] Erasmus MC, Dept Radiol, Rotterdam, Netherlands
[2] Univ Copenhagen, Dept Comp Sci, Copenhagen, Denmark
[3] Erasmus MC, Dept Radiol, Rotterdam, Netherlands
[4] Delft Univ Technol, Fac Appl Sci, Delft, Netherlands
来源
MEDICAL IMAGE COMPUTING AND COMPUTER-ASSISTED INTERVENTION - MICCAI 2013, PT II | 2013年 / 8150卷
关键词
D O I
暂无
中图分类号
TP18 [人工智能理论];
学科分类号
081104 ; 0812 ; 0835 ; 1405 ;
摘要
We present a new approach for automated segmentation of the carotid lumen bifurcation from 3D free-hand ultrasound using a 3D surface graph cut method. The method requires only the manual selection of single seed points in the internal, external, and common carotid arteries. Subsequently, the centerline between these points is automatically traced, and the optimal lumen surface is found around the centerline using graph cuts. To refine the result, the latter process was iterated. The method was tested on twelve carotid arteries from six subjects including three patients with a moderate carotid artery stenosis. Our method successfully segmented the lumen in all cases. We obtained an average dice overlap with respect to a manual segmentation of 84% for healthy volunteers. For the patient data, we obtained a dice overlap of 66.7%.
引用
收藏
页码:542 / 549
页数:8
相关论文
共 50 条
  • [31] Semiautomatic segmentation of atherosclerotic carotid artery wall volume using 3D ultrasound imaging
    Hossain, Md. Murad
    AlMuhanna, Khalid
    Zhao, Limin
    Lal, Brajesh K.
    Sikdar, Siddhartha
    MEDICAL PHYSICS, 2015, 42 (04) : 2029 - 2043
  • [32] Segmentation of the Carotid Artery in Ultrasound Images Using Neural Networks
    Menchon-Lara, Rosa-Maria
    Bastida-Jumilla, M-Consuelo
    Morales-Sanchez, Juan
    Verdu-Monedero, Rafael
    Larrey-Ruiz, Jorge
    Luis Sancho-Gomez, Jose
    NEW CHALLENGES ON BIOINSPIRED APPLICATIONS: 4TH INTERNATIONAL WORK-CONFERENCE ON THE INTERPLAY BETWEEN NATURAL AND ARTIFICIAL COMPUTATION, IWINAC 2011, PART II, 2011, 6687 : 463 - 471
  • [33] Free-hand sketches for 3D model retrieval using cascaded LSDA
    Chin-Ting Tu
    Po-Chung Lin
    Jenn-Jier Lien
    Multimedia Tools and Applications, 2017, 76 : 11669 - 11685
  • [34] Carotid Artery Wall Segmentation in Multispectral MRI by Coupled Optimal Surface Graph Cuts
    Arias-Lorza, Andres M.
    Petersen, Jens
    van Engelen, Arna
    Selwaness, Mariana
    van der Lugt, Aad
    Niessen, Wiro J.
    de Bruijne, Marleen
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2016, 35 (03) : 901 - 911
  • [35] Free-hand sketches for 3D model retrieval using cascaded LSDA
    Tu, Chin-Ting
    Lin, Po-Chung
    Lien, Jenn-Jier
    MULTIMEDIA TOOLS AND APPLICATIONS, 2017, 76 (09) : 11669 - 11685
  • [36] Moving object segmentation using dynamic 3D graph cuts and GMM
    Li, Bo
    Yuan, Baozong
    Sun, Yunda
    2006 8TH INTERNATIONAL CONFERENCE ON SIGNAL PROCESSING, VOLS 1-4, 2006, : 1559 - +
  • [37] 3D liver segmentation using multiple region appearances and graph cuts
    Peng, Jialin
    Hu, Peijun
    Lu, Fang
    Peng, Zhiyi
    Kong, Dexing
    Zhang, Hongbo
    MEDICAL PHYSICS, 2015, 42 (12) : 6840 - 6852
  • [38] 3D VERTEBRAE SEGMENTATION USING GRAPH CUTS WITH SHAPE PRIOR CONSTRAINTS
    Aslan, Melih S.
    Ali, Asem
    Chen, Dongqing
    Arnold, Ben
    Farag, Aly A.
    Xiang, Ping
    2010 IEEE INTERNATIONAL CONFERENCE ON IMAGE PROCESSING, 2010, : 2193 - 2196
  • [39] Carotid artery segmentation and characterization in 3D computed tomography (CT) images
    Zuluaga, M. A.
    Davila, E. E.
    Uriza, L. F.
    Hernandez Hoyos, M.
    INTERNATIONAL JOURNAL OF COMPUTER ASSISTED RADIOLOGY AND SURGERY, 2007, 2 : S72 - S74
  • [40] Better foreground segmentation for 3D face reconstruction using graph cuts
    Park, Anjin
    Hong, Kwangjin
    Jung, Keechul
    ADVANCES IN IMAGE AND VIDEO TECHNOLOGY, PROCEEDINGS, 2007, 4872 : 715 - 726