Indoor Thermal Environment Long-Term Data Analytics Using IoT Devices in Korean Apartments: A Case Study

被引:3
作者
Yun, Hyunjun [1 ,2 ]
Yang, Jinho [1 ]
Lee, Byong Hyoek [2 ]
Kim, Jongcheol [2 ]
Sohn, Jong-Ryeul [3 ]
机构
[1] Korea Univ, Dept Hlth & Safety Convergence Sci, Grad Sch, 73 Goryeodae Ro, Seoul 02841, South Korea
[2] Coway Co LTD, Environm Technol Inst, 1 Gwanak Ro, Seoul 08826, South Korea
[3] Korea Univ, Dept Publ Hlth Sci, Grad Sch, 73 Goryeodae Ro, Seoul 02841, South Korea
关键词
thermal environment; temperature; relative humidity; IoT-based devices; long-term; personal exposure; OUTDOOR TEMPERATURE; CLIMATE-CHANGE; HUMIDITY; EXPOSURE; COMFORT; HEALTH;
D O I
10.3390/ijerph17197334
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
IoT-based monitoring devices can transmit real-time and long-term thermal environment data, enabling innovative conversion for the evaluation and management of the indoor thermal environment. However, long-term indoor thermal measurements using IoT-based devices to investigate health effects have rarely been conducted. Using apartments in Seoul as a case study, we conducted long-term monitoring of thermal environmental using IoT-based real-time wireless sensors. We measured the temperature, relative humidity (RH), and CO2 in the kitchen, living room, and bedrooms of each household over one year. In addition, in one of the houses, velocity and globe temperatures were measured for multiple summer and autumn seasons. Results of our present study indicated that outdoor temperature is an important influencing factor of indoor thermal environment and indoor RH is a good indicator of residents' lifestyle. Our findings highlighted the need for temperature management in summer, RH management in winter, and kitchen thermal environment management during summer and tropical nights. This study suggested that IoT devices are a potential approach for evaluating personal exposure to indoor thermal environmental risks. In addition, long-term monitoring and analysis is an efficient approach for analyzing complex indoor thermal environments and is a viable method for application in healthcare.
引用
收藏
页码:1 / 15
页数:15
相关论文
共 34 条
[1]  
[Anonymous], R: A Language and Environment for Statistical Computing
[2]  
[Anonymous], 2005, E77302005 ISO
[3]  
[Anonymous], 2007, 152512007 INDOOR ENV
[4]  
[Anonymous], **DATA OBJECT**
[5]  
[Anonymous], 1998, EN7726 ISO, V7726
[6]  
ASHRAE Standard, 2004, 552004 ASHRAE ANSIAS, V2004, P1
[7]   Research on seasonal indoor thermal environment and residents' control behavior of cooling and heating systems in Korea [J].
Bae, Chihye ;
Chun, Chungyoon .
BUILDING AND ENVIRONMENT, 2009, 44 (11) :2300-2307
[8]   A public health needs assessment for domestic indoor overheating [J].
Bundle, N. ;
O'Connell, E. ;
O'Connor, N. ;
Bone, A. .
PUBLIC HEALTH, 2018, 161 :147-153
[9]  
Cast JW M, 2020, MED SCI SPORT EXER, V34, P2013
[10]   Development of low-cost indoor air quality monitoring devices: Recent advancements [J].
Chojer, H. ;
Branco, P. T. B. S. ;
Martins, F. G. ;
Alvim-Ferraz, M. C. M. ;
Sousa, S. I., V .
SCIENCE OF THE TOTAL ENVIRONMENT, 2020, 727