Welded aluminium alloy connections: test results and BS8118

被引:25
作者
Chan, TK
Goff, RFDP
机构
[1] Nanyang Technol Univ, Sch Civil & Struct Engn, Singapore 639798, Singapore
[2] Univ Cambridge, Dept Engn, Cambridge CB2 1PZ, England
关键词
heat-affected zones; reduced-strength zone; welded aluminium joints;
D O I
10.1016/S0263-8231(00)00006-9
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Heat-treatable aluminium alloys are known to suffer from severe loss of strength in the vicinity of welds. This investigation examines the structural effect of a reduced strength zone adjacent to the welds of cruciform connections and assesses its effects on the load carrying capacity, ductility and mode of failure. The results indicate that the load carrying capacity for short connection lengths are lower than values predicted with current methods of design and that the mode of failure is usually with a distinctive dish-like necking around the welded finger within the RSZ of the joint. (C) 2000 Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:265 / 287
页数:23
相关论文
共 10 条
  • [1] BARTLE PM, 1965, P 2 COMM WELD C WELD, P246
  • [2] BARTLE PM, 1969, P C WELD AL ZN MG AL, P5
  • [3] *BRIT STAND I, 1991, 8118 BRIT STAND I
  • [4] CHAN TK, 1992, P 3 INT C AL ALL THE, P69
  • [5] CHAN TK, 1992, THESIS CAMBRIDGE U
  • [6] Chang T.M.S., 1991, P MAT TEC 91, P305
  • [7] CULLIMORE MSG, 1992, P 5 INT C AL WELDM
  • [8] Hill HN, 1960, P AM SOC CIVIL ENG, V86, P101
  • [9] KELSEY RA, 1971, WELDING J RES S12, V50, P507
  • [10] ROBERTSON I, 1985, THESIS CAMBRIDGE U