Investigations on safety of hyperthermic intraoperative intraperitoneal chemotherapy (HIPEC) with Mitomycin C

被引:49
作者
Schmid, K.
Boettcher, M. I.
Pelz, J. O. W.
Meyer, T.
Korinth, G.
Angerer, J.
Drexler, H.
机构
[1] Univ Erlangen Nurnberg, Inst Occupat Social & Environm Med, D-91054 Erlangen, Germany
[2] Univ Erlangen Nurnberg, Outpatient Clin Occupat Social & Environm Med, D-91054 Erlangen, Germany
[3] Univ Erlangen Nurnberg, Dept Surg, D-91054 Erlangen, Germany
来源
EJSO | 2006年 / 32卷 / 10期
关键词
hyperthermic intraoperative intraperitoneal chemotherapy; Mitomycin C; latex gloves; safety monitoring;
D O I
10.1016/j.ejso.2006.05.011
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Aims: Previous safety monitoring of hyperthermic intraoperative intraperitoneal chemotherapy (HIPEC) with Mitomycin C (MMC) did not demonstrate any detectable safety hazard to the personnel. Nevertheless, those results have been discussed controversially because of the methodological problems employed in the evaluation of potential exposure. We re-evaluated possible safety hazards of HIPEC by applying different monitoring strategies. Methods: We monitored air samples in the operation room during HIPEC. In addition, we measured MMC in plasma of the surgeon with a newly developed analytical method. All samples were analysed by HPLC-UV at 360 nm. The permeability of the gloves was tested using two in vitro techniques: diffusion cells and a glass cell chamber. In-use and worst-case exposure scenarios were imitated for in vitro experiments. Results: The analysis of the air samples (n=3) could not detect any MMC. We found no drug above the limit of detection (1 mu g MMC/L) in the plasma samples of the surgeons (n=5). A breakthrough of latex glove material was detected in only one (worst-case exposure scenario) of 40 diffusion cell experiments. Conclusions: Established methods of safety monitoring could not reveal any detectable risk on in-use exposure conditions. The wearing of doubled latex gloves should prevent the surgeon from dermal exposure to MMC during HIPEC. (c) 2006 Elsevier Ltd. All rights reserved.
引用
收藏
页码:1222 / 1225
页数:4
相关论文
共 16 条
[1]   Cytoreduction and intraperitoneal chemotherapy for the management of peritoneal carcinomatosis, sarcomatosis and mesothelioma [J].
Begossi, G ;
Gonzalez-Moreno, S ;
Ortega-Perez, G ;
Fon, LJ ;
Sugarbaker, PH .
EUROPEAN JOURNAL OF SURGICAL ONCOLOGY, 2002, 28 (01) :80-87
[2]   Permeability of nitrile rubber, latex, polyurethane, and neoprene gloves to 18 antineoplastic drugs [J].
Connor, TH .
AMERICAN JOURNAL OF HEALTH-SYSTEM PHARMACY, 1999, 56 (23) :2450-2453
[3]   Determination of the vaporization of solutions of mutagenic antineoplastic agents at 23 and 37°C, using a desiccator technique [J].
Connor, TH ;
Shults, M ;
Fraser, MP .
MUTATION RESEARCH-GENETIC TOXICOLOGY AND ENVIRONMENTAL MUTAGENESIS, 2000, 470 (01) :85-92
[4]  
Connor TH, 2003, ANN SURG ONCOL, V10, P821, DOI 10.1245/ASO.2003.03.988
[5]  
Dranitsaris George, 2005, J Oncol Pharm Pract, V11, P69, DOI 10.1191/1078155205jp155oa
[6]   Assignment of skin notation for MAK values and its legal consequences in Germany [J].
Drexler, H .
INTERNATIONAL ARCHIVES OF OCCUPATIONAL AND ENVIRONMENTAL HEALTH, 1998, 71 (07) :503-505
[7]   PERCUTANEOUS ABSORPTION - RELEVANCE OF INVITRO DATA [J].
FRANZ, TJ .
JOURNAL OF INVESTIGATIVE DERMATOLOGY, 1975, 64 (03) :190-195
[8]  
*IARC, 1976, IARC MON EV CARC RIS, V10, P171
[9]   Percutaneous absorption of neat and aqueous solutions of 2-butoxyethanol in volunteers [J].
Jakasa, I ;
Mohammadi, N ;
Krüse, J ;
Kezic, S .
INTERNATIONAL ARCHIVES OF OCCUPATIONAL AND ENVIRONMENTAL HEALTH, 2004, 77 (02) :79-84
[10]  
Kiffmeyer TK, 2002, PHARM J, V268, P331