Cloud point extraction and flame atomic absorption spectrometry determination of trace amounts of copper(II) ions in water samples

被引:51
作者
Fathi, S. A. M. [1 ]
Yaftian, M. R. [1 ]
机构
[1] Zanjan Univ, Fac Sci, Dept Chem, Phase Equilibria Res Lab, Zanjan, Iran
关键词
Cloud point extraction; Pre-concentration; Copper(II); Schiff base; Water samples; ENVIRONMENTAL-SAMPLES; HEAVY-METALS; PRECONCENTRATION; BASE; PHASE; ENRICHMENT; SEPARATION; IONOPHORE; LIGAND; CU;
D O I
10.1016/j.jcis.2009.02.071
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
Cloud point extraction was used with lipophilic Schiff base N,N'-bis(2-hydroxyacetophenone)-1,2-propanediimine (L) as a pre-concentration step prior to flame atomic absorption spectrometry determination of trace amounts of copper in water samples. The process is based upon the formation of Cu(II)/L complexes soluble in a micellar phase composed by the non-ionic surfactant Triton X-114. These complexes are then extracted into the surfactant-rich phase, at above its cloud point temperature. The parameters affecting the extraction efficiency, i.e. pH of aqueous solution, concentration of the Schiff base, amount of the surfactant, incubation temperature, and time were investigated. Under the Optimum experimental conditions, the calibration graph was linear in the range 0.1-1300 ng ml(-1) with a limit of detection of 0.06 ng ml(-1). The proposed method was successfully applied for the determination of copper in various water samples. (C) 2009 Elsevier Inc. All rights reserved
引用
收藏
页码:167 / 170
页数:4
相关论文
共 27 条
[1]  
*AM PUBL HLTH ASS, 1995, STAND METH EX WAT WA
[2]  
[Anonymous], 2003, ULLMANS ENCY IND CHE
[3]  
[Anonymous], 2004, TOXICOLOGICAL PROFIL
[4]   Lanthanum(III) and gadolinium(III) separation by cloud point extraction [J].
De Jong, N ;
Draye, M ;
Favre-Réguillon, A ;
LeBuzit, G ;
Cote, G ;
Foos, J .
JOURNAL OF COLLOID AND INTERFACE SCIENCE, 2005, 291 (01) :303-306
[5]   Preconcentration of Pb(II), Cr(III), Cu(II), Ni(II) and Cd(II) ions in environmental samples by membrane filtration prior to their flame atomic absorption spectrometric determinations [J].
Divrikli, Umit ;
Kartal, Aslihan Arslan ;
Soylak, Mustafa ;
Elci, Latif .
JOURNAL OF HAZARDOUS MATERIALS, 2007, 145 (03) :459-464
[6]  
Emadi D, 2007, TURK J CHEM, V31, P423
[7]   Multidentate nitrogen/oxygen donor ionophores; their use as selective extracting and mobile-carrier agents for copper(II) ions [J].
Fathi, S. A. M. ;
Parinejad, M. ;
Yaftian, M. R. .
SEPARATION AND PURIFICATION TECHNOLOGY, 2008, 64 (01) :1-7
[8]   Enrichment of trace amounts of copper(II) ions in water samples using octadecyl silica disks modified by a Schiff base ionophore prior to flame atomic absorption spectrometric determination [J].
Fathi, S. A. M. ;
Yaftian, M. R. .
JOURNAL OF HAZARDOUS MATERIALS, 2009, 164 (01) :133-137
[9]   LIGAND DESIGN FOR SELECTIVE COMPLEXATION OF METAL-IONS IN AQUEOUS-SOLUTION [J].
HANCOCK, RD ;
MARTELL, AE .
CHEMICAL REVIEWS, 1989, 89 (08) :1875-1914
[10]   A CRITICAL-REVIEW OF SURFACTANT-MEDIATED PHASE SEPARATIONS (CLOUD-POINT EXTRACTIONS) - THEORY AND APPLICATIONS [J].
HINZE, WL ;
PRAMAURO, E .
CRITICAL REVIEWS IN ANALYTICAL CHEMISTRY, 1993, 24 (02) :133-177