Characteristics of anterior inferior calcaneal cortex

被引:6
作者
Harnroongroj, T. [1 ]
Jiamamornrat, S. [1 ]
Tharmviboonsri, T. [1 ]
机构
[1] Mahidol Univ, Siriraj Hosp, Fac Med, Dept Orthopaed & Rehabil, 2 Prannok St, Bangkok 10700, Thailand
关键词
Anterior inferior calcaneal cortex; Surface anatomy; Width; Length; Cortical thickness; Percutaneous screw fixation; Tongue type calcaneal fracture; DISPLACED INTRAARTICULAR FRACTURES; REDUCTION;
D O I
10.1016/j.fas.2017.12.009
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Minimal invasive surgery of calcaneal fracture provided satisfactory outcomes. In tongue type calcaneal fracture, percutaneous screw usually purchases in anterior inferior calcaneal cortex. However, there was no detail about the cortex of anterior inferior calcaneus so the surface anatomy and cortical thickness of this area were studied. Methods: 88 calcaneus from embalmed cadavers were enrolled. Anterior part of the inferior cortex was identified. Surface anatomy was examined. Length, anterior and posterior widths were measured. Anterior inferior calcaneal cortex was divided into anterior, middle and posterior segments. The cortical thickness at middle, medial most and lateral most of 3 segments were measured. Results: Anterior inferior calcaneal cortex was a long trapezoidal shape with well-defined borders as a dense and thick cortical bone, convex relief from medial and lateral walls. Mean(SD) length was 33.40 (3.46) millimeters (mm). Median(min,max) of anterior and posterior width were 10.50(8.21,19.26) mm and 14.00(10.05,20.42) mm, respectively. Mean(SD) of middle cortical thickness of anterior and middle segment were 3.12(0.76) and 3.72(0.74). Median(min,max) middle cortical thickness of posterior segment was 3.13(1.62,6.51) mm. Whereas, of the medial most were 1.31(0.78,3.11), 1.31(0.90,2.57) and 1.26(0.85,2.61) mm and of the lateral most were 1.17(0.67,2.64), 1.38(0.80,2.55) and 1.31(0.84,2.61) mm, respectively. Inter-intraobserver reliabilities of the measurements were >0.79. The statistical analysis showed the middle cortex is significantly the thickest (P < 0.001) and posterior width is significant wider than the anterior (P < 0.001). Conclusions: Anterior inferior calcaneal cortex has special characteristics in term of surface anatomy, width and thickness. For the percutaneous screw insertion from posterosuperior to anterior inferior calcaneus in tongue type calcaneal fracture, we recommend that screw should purchase in middle cortex due to maximal cortical thickness as well as its cortical width could accept 6.5 or 7.0 mm screw without screw extrusion. (c) 2017 European Foot and Ankle Society. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:323 / 326
页数:4
相关论文
共 16 条
[1]  
Abdelgaid Sherif Mohamed, 2012, Foot Ankle Surg, V18, P164, DOI 10.1016/j.fas.2011.07.005
[2]  
Abusenna AS, 2011, AAMJ, V9, P227
[3]  
Bolliger Neto R, 1999, Rev Hosp Clin Fac Med Sao Paulo, V54, P181
[4]  
Dalal BY, 2013, INT J RES ORTHOP, V2, P371
[5]  
Devendrappa H, 2016, Indian J Orthop Surg, V2, P115, DOI [10.5958/2395-1362.2016.00022.0, DOI 10.5958/2395-1362.2016.00022.0]
[6]   Determination of the role of the cancellous bone in generation of screw holding power at metaphysis [J].
Harnroongroj, T ;
Techataweewan, A .
CLINICAL BIOMECHANICS, 1999, 14 (05) :364-366
[7]   Biomechanical Evaluation of Subtalar Fusion: The Influence of Screw Configuration and Placement [J].
Hungerer, Sven ;
Eberle, Sebastian ;
Lochner, Susanne ;
Maier, Michael ;
Hoegel, Florian ;
Penzkofer, Rainer ;
Augat, Peter .
JOURNAL OF FOOT & ANKLE SURGERY, 2013, 52 (02) :177-183
[8]   Medial Displacement Calcaneal Osteotomy Using Minimally Invasive Technique [J].
Kheir, Ehab ;
Borse, Vishal ;
Sharpe, Jon ;
Lavalette, David ;
Farndon, Mark .
FOOT & ANKLE INTERNATIONAL, 2015, 36 (03) :248-252
[9]   Compressive Force With 2-Screw and 3-Screw Subtalar Joint Arthrodesis With Headless Compression Screws [J].
Matsumoto, Takumi ;
Glisson, Richard R. ;
Reidl, Markus ;
Easley, Mark E. .
FOOT & ANKLE INTERNATIONAL, 2016, 37 (12) :1357-1363
[10]   Percutaneous reduction and fixation of an intra-articular calcaneal fracture using an inflatable bone tamp: Description of a novel and safe technique [J].
Cyril Mauffrey ;
James R Bailey ;
David J Hak ;
Mark E Hammerberg .
Patient Safety in Surgery, 6 (1)