Endotoxins in Indoor Air and Settled Dust in Primary Schools in a Subtropical Climate

被引:24
作者
Salonen, Heidi [1 ,2 ]
Duchaine, Caroline [3 ,4 ]
Letourneau, Valerie [4 ]
Mazaheri, Mandana [1 ]
Clifford, Sam [1 ,5 ]
Morawska, Lidia [1 ]
机构
[1] Queensland Univ Technol, Int Lab Air Qual & Hlth, Brisbane Q, Qld 4001, Australia
[2] Finnish Inst Occupat Hlth, Helsinki 00250, Finland
[3] Univ Laval, Dept Biochem Microbiol & Bioinformat, Quebec City, PQ G1V 0A6, Canada
[4] Inst Univ Cardiol & Pneumol Quebec, Ctr Rech, Quebec City, PQ G1V 4G5, Canada
[5] Ctr Air Qual & Hlth Res & Evaluat, Glebe, NSW 2037, Australia
基金
澳大利亚研究理事会;
关键词
DAY-CARE-CENTERS; AIRBORNE ENDOTOXIN; HOUSE-DUST; EXPOSURE ASSESSMENT; ENVIRONMENTAL EXPOSURE; ASTHMA; HOMES; DETERMINANTS; PREDICTORS; EXTRACTION;
D O I
10.1021/es4023706
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Endotoxins can significantly affect the air quality. in school environments. However, there is currently no reliable method for the measurement of endotoxins, and there is a lack of reference values for endotoxin concentrations to aid in the interpretation of measurement results in school settings. We benchmarked the "baseline" range of endotoxin concentration in indoor air, together with endotoxin load in floor dust, and evaluated the correlation between endotoxin levels in indoor air and settled dust, as well as the effects of temperature and humidity on these levels in subtropical school settings. Bayesian hierarchical modeling indicated that the concentration in indoor air and the load in floor dust were generally (<95th percentile) <13 EU/m(3) and <24,570 EU/m(2), respectively. Exceeding these levels would indicate abnormal sources of endotoxins in the school environment and the need for further investigation. Metaregression indicated no relationship between endotoxin concentration and load, which points to the necessity for measuring endotoxin levels in both the air and settled dust. Temperature increases were associated with lower concentrations in indoor air and higher loads in floor dust. Higher levels of humidity may be associated with lower airborne endotoxin concentrations.
引用
收藏
页码:9882 / 9890
页数:9
相关论文
共 66 条
[1]  
[Anonymous], 2009, NAT VENT INF CONTR H
[2]  
Australian Government Bureau of Meteorology, CLIM STAT AUSTR LOC
[3]  
Australian Weather and the Seasons. Australian Government, 2012, AUSTR WEATH SEAS
[4]   Predictors of high endotoxin concentrations in the settled dust of German homes [J].
Bischof, W ;
Koch, A ;
Gehring, U ;
Fahlbusch, B ;
Wichmann, HE ;
Heinrich, J .
INDOOR AIR, 2002, 12 (01) :2-9
[5]   Environmental exposure to endotoxin and its relation to asthma in school-age children [J].
Braun-Fahrländer, C ;
Riedler, J ;
Herz, U ;
Eder, W ;
Waser, M ;
Grize, L ;
Maisch, S ;
Carr, D ;
Gerlach, F ;
Bufe, A ;
Lauener, RP ;
Schierl, R ;
Renz, H ;
Nowak, D ;
von Mutius, E .
NEW ENGLAND JOURNAL OF MEDICINE, 2002, 347 (12) :869-877
[6]   Geographical variation and the determinants of domestic endotoxin levels in mattress dust in Europe [J].
Chen, C. -M. ;
Thiering, E. ;
Doekes, G. ;
Zock, J. -P. ;
Bakolis, I. ;
Norback, D. ;
Sunyer, J. ;
Villani, S. ;
Verlato, G. ;
Taubel, M. ;
Jarvis, D. ;
Heinrich, J. .
INDOOR AIR, 2012, 22 (01) :24-32
[7]  
Chun D T, 2000, Appl Occup Environ Hyg, V15, P152
[8]   Airborne endotoxin is associated with respiratory illness in the first 2 years of life [J].
Dales, R ;
Miller, D ;
Ruest, K ;
Guay, M ;
Judek, S .
ENVIRONMENTAL HEALTH PERSPECTIVES, 2006, 114 (04) :610-614
[9]  
Delfino R.J., 2011, ENV HLTH, V10, P1
[10]  
DONHAM K, 1989, BRIT J IND MED, V46, P31