The finite element analysis of the effect of ferrule height on stress distribution at post-and-core-restored all-ceramic anterior crowns

被引:72
作者
Eraslan, Oguz [1 ]
Aykent, Filiz [1 ]
Yucel, M. Tolga [1 ]
Akman, Serhan [1 ]
机构
[1] Selcuk Univ, Dept Prosthodont, Fac Dent, TR-42079 Konya, Turkey
关键词
Finite element analysis; Ferrule effect; All-ceramic anterior crown; Post-core; Stress distribution; ENDODONTICALLY TREATED TEETH; FIXED PARTIAL DENTURES; PULPLESS TEETH; DESIGN; RESISTANCE; BONE; FRACTURE; RESTORATIONS; IMPLANTS; TOOTH;
D O I
10.1007/s00784-008-0217-5
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
The purpose of this study was to compare the effect of ferrule with different heights on the stress distribution of dentin and the restoration-tooth complex, using the finite element stress analysis method. Three-dimensional finite element models simulating an endodontically treated maxillary central incisor restored with an all-ceramic crown were prepared. Three-dimensional models were varied in their ferrule height (NF: no ferrule, 1F: 1-mm ferrule, and 2F: 2-mm ferrule). A 300-N static occlusal load was applied to the palatal surface of the crown with a 135 degrees angle to the long axis of the tooth. In addition, two post and core materials with different elastic modulus were evaluated. The differences in stress transfer characteristics of the models were analyzed. Maximum stresses were concentrated on force application areas (32.6-32.8 MPa). The stress values observed with the use of a 2-mm ferrule (14.1/16.8 MPa) were lower than the no-ferrule design (14.9/17.1 MPa) for both the glass fiber-reinforced and zirconium oxide ceramic post systems, respectively. The stress values observed with zirconium oxide ceramic were higher than that of glass fiber-reinforced post system. The use of a ferrule in endodontically treated teeth restored with an all-ceramic post-and-core reduces the values of von Mises stresses on tooth-restoration complex. At rigid zirconium oxide ceramic post system, stress levels, both at dentin wall and within the post, were higher than that of fiber posts.
引用
收藏
页码:223 / 227
页数:5
相关论文
共 31 条
[1]  
Akça K, 2001, INT J ORAL MAX IMPL, V16, P722
[2]   Finite element analysis of stresses in endodontically treated, dowel-restored teeth [J].
Asmussen, E ;
Peutzfeldt, A ;
Sahafi, A .
JOURNAL OF PROSTHETIC DENTISTRY, 2005, 94 (04) :321-329
[3]   EFFECT OF POST DESIGN ON RESISTANCE TO FRACTURE OF ENDODONTICALLY TREATED TEETH WITH COMPLETE CROWNS [J].
ASSIF, D ;
BITENSKI, A ;
PILO, R ;
OREN, E .
JOURNAL OF PROSTHETIC DENTISTRY, 1993, 69 (01) :36-40
[4]   PHOTOELASTIC ANALYSIS OF STRESS TRANSFER BY ENDODONTICALLY TREATED TEETH TO THE SUPPORTING STRUCTURE USING DIFFERENT RESTORATIVE TECHNIQUES [J].
ASSIF, D ;
OREN, E ;
MARSHAK, BL ;
AVIV, I .
JOURNAL OF PROSTHETIC DENTISTRY, 1989, 61 (05) :535-543
[5]   Effect of adhesive layer properties on stress distribution in composite restorations - a 3D finite element analysis [J].
Ausiello, P ;
Apicella, A ;
Davidson, CL .
DENTAL MATERIALS, 2002, 18 (04) :295-303
[6]  
BEER FP, 1993, TRANSFORMATIONS STRE, P367
[7]   Stress distribution in a post-restored tooth using the three-dimensional finite element method [J].
Boschian Pest, L. ;
Guidotti, S. ;
Pietrabissa, R. ;
Gagliani, M. .
JOURNAL OF ORAL REHABILITATION, 2006, 33 (09) :690-697
[8]   A FINITE-ELEMENT ANALYSIS OF THE HUMAN TEMPOROMANDIBULAR-JOINT [J].
CHEN, J ;
XU, LF .
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 1994, 116 (04) :401-407
[9]   MECHANICAL-PROPERTIES AND SHORT-TERM INVIVO EVALUATION OF YTTRIUM-OXIDE-PARTIALLY-STABILIZED ZIRCONIA [J].
CHRISTEL, P ;
MEUNIER, A ;
HELLER, M ;
TORRE, JP ;
PEILLE, CN .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 1989, 23 (01) :45-61
[10]   Effects of cantilever design and material on stress distribution in fixed partial dentures - a finite element analysis [J].
Eraslan, O ;
Sevimay, M ;
Usumez, A ;
Eskitascioglu, G .
JOURNAL OF ORAL REHABILITATION, 2005, 32 (04) :273-278