Wind tunnel and full-scale study of wind effects on a super-tall building

被引:72
作者
Yi, Jun [1 ]
Li, Q. S. [1 ]
机构
[1] City Univ Hong Kong, Dept Architecture & Civil Engn, Kowloon, Hong Kong, Peoples R China
基金
中国国家自然科学基金;
关键词
Wind tunnel test; Full-scale measurement; Wind effects; Tall building; Typhoon; FIELD-MEASUREMENTS; INDUCED RESPONSE; GPS; FREQUENCY; VIBRATION;
D O I
10.1016/j.jfluidstructs.2015.08.005
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
This paper presents the analyzed results from a combined wind tunnel and full-scale study of the wind effects on a super-tall building with a height of 420 m in Hong Kong. In wind tunnel tests, mean and fluctuating forces and pressures on the building models for the cases of an isolated building and the building with the existing surrounding condition are measured by the high-frequency force balance technique and synchronous multipressure sensing system under two typical boundary layer wind flow fields. Global and local wind force coefficients and structural responses are presented and discussed. A detailed study is conducted to investigate the influences of incident wind direction, upstream terrain conditions and interferences from the surroundings on the wind loads and responses of the high-rise structure. On the other hand, full-scale measurements of the wind effects on the super-tall building have been performed under typhoon conditions. The field data, such as wind speed, wind direction, structural acceleration and displacement responses have been simultaneously and continuously recorded during the passage of 12 typhoons since 2008. Analysis of the field measured data is carried out to investigate the typhoon effects on the super-tall building. Finally, the model test results are compared with the full-scale measurements for verification of the wind tunnel test techniques. The comparative study shows that the wind tunnel testing can provide reasonable predictions of the structural resonant responses. The resonant displacement responses are comparable to the background displacement responses so that the contribution of the background responses to the total displacement responses should not be underestimated. The outcome of the combined wind tunnel and full-scale study is expected to be useful to engineers and researchers involved in the wind-resistant design of super-tall buildings. (c) 2015 Elsevier Ltd. All rights reserved.
引用
收藏
页码:236 / 253
页数:18
相关论文
共 43 条
[1]  
[Anonymous], 1993, ENG APPL CORRELATION, DOI DOI 10.2514/3.49131
[2]  
[Anonymous], THESIS U NOTRE DAME
[3]   Experimental monitoring of the Humber bridge using GPS [J].
Ashkenazi, V ;
Roberts, GW .
PROCEEDINGS OF THE INSTITUTION OF CIVIL ENGINEERS-CIVIL ENGINEERING, 1997, 120 (04) :177-182
[4]  
Boundary Layer Wind Tunnel Laboratory (BLWTL), 1999, WIND TUNN TEST GEN O
[5]   Monitoring of structures using the global positioning system [J].
Brown, CJ ;
Karuna, R ;
Ashkenazi, V ;
Roberts, GW ;
Evans, RA .
PROCEEDINGS OF THE INSTITUTION OF CIVIL ENGINEERS-STRUCTURES AND BUILDINGS, 1999, 134 (01) :97-105
[6]   Field measurements of natural periods of vibration and structural damping of wind-excited tall residential buildings [J].
Campbell, S. ;
Kwok, K. C. S. ;
Hitchcock, P. A. ;
Tse, K. T. ;
Leung, H. Y. .
WIND AND STRUCTURES, 2007, 10 (05) :401-420
[7]   GPS in pioneering dynamic monitoring of long-period structures [J].
Çelebi, M ;
Sanli, A .
EARTHQUAKE SPECTRA, 2002, 18 (01) :47-61
[8]   Assessment of dynamic measurement accuracy of GPS in three directions [J].
Chan, Wai-Shan ;
Xu, You-Lin ;
Ding, Xiao-Li ;
Xiong, Yong-Liang ;
Dai, Wu-Jiao .
JOURNAL OF SURVEYING ENGINEERING, 2006, 132 (03) :108-117
[9]  
Cole H.A., 1973, ON LINE FAILURE DETE
[10]   Monitoring system of the Akashi Kaikyo Bridge and displacement measurement using GPS [J].
Fujino, Y ;
Murata, M ;
Okano, S ;
Takeguchi, M .
NONDESTRUCTIVE EVALUATION OF HIGHWAYS, UTILITIES, AND PIPELINES IV, 2000, 3995 :229-236