Whole-Heart Contrast-Enhanced Coronary Magnetic Resonance Angiography Using Gradient Echo Interleaved EPI

被引:6
|
作者
Bhat, Himanshu [2 ,3 ]
Zuehlsdorff, Sven [1 ]
Bi, Xiaoming [1 ]
Li, Debiao [2 ,3 ]
机构
[1] Siemens Med Solut USA Inc, Chicago, IL USA
[2] Northwestern Univ, Dept Radiol, Chicago, IL 60611 USA
[3] Northwestern Univ, Dept Biomed Engn, Chicago, IL 60611 USA
基金
美国国家卫生研究院;
关键词
coronary arteries; magnetic resonance angiography; interleaved EPI; contrast media; MR-ANGIOGRAPHY; VOLUME; MOTION; ARTERIES; MINUTES; SCANNER; HUMANS; 3T;
D O I
10.1002/mrm.21963
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Whole-heart coronary MR angiography (MRA) is a promising method for detecting coronary artery disease. However, the imaging time is relatively long (on the order of 10-15 min). Such a long imaging time may result in patient discomfort and compromise the robustness of whole-heart coronary MRA due to increased respiratory and cardiac motion artifacts. The goal of this study was to optimize a gradient echo interleaved echo planar imaging (GRE-EPI) acquisition scheme for reducing the imaging time of contrast-enhanced whole-heart coronary MRA. Numerical simulations and phantom studies were used to optimize the GRE-EPI sequence parameters. Healthy volunteers were scanned with both the proposed GRE-EPI sequence and a 3D TrueFISP sequence for comparison purposes. Slow infusion (0.5 cc/sec) of Gd-DTPA was used to enhance the signal-to-noise ratio (SNR) of the GRE-EPI acquisition. Whole-heart images with the GRE-EPI technique were acquired with a true resolution of 1.0 x 1.1 x 2.0 mm(3) in an average scan time of 4.7 +/- 0.7 min with an average navigator efficiency of 44 +/- 6%. The GRE-EPI acquisition showed excellent delineation of all the major coronary arteries with scan time reduced by a factor of 2 compared with the TrueFISP acquisition. Magn Reson Med 61: 1388-1395, 2009. (C) 2009 Wiley-Liss, Inc.
引用
收藏
页码:1388 / 1395
页数:8
相关论文
共 50 条
  • [41] Prospective Heart Tracking for Respiratory Motion Compensation in Whole-heart Magnetic Resonance Angiography
    Mehdi Hedjazi Moghari
    Tal Geva
    Andrew J Powell
    Journal of Cardiovascular Magnetic Resonance, 18 (Suppl 1)
  • [42] Contrast-Kinetics-Resolved Whole-Heart Coronary MRA Using 3DPR
    Lai, Peng
    Huang, Feng
    Li, Yu
    Nielles-Vallespin, Sonia
    Bi, Xiaoming
    Jerecic, Renate
    Li, Debiao
    MAGNETIC RESONANCE IN MEDICINE, 2010, 63 (04) : 970 - 978
  • [43] Coronary artery assessment using self-navigated free-breathing radial whole-heart magnetic resonance angiography in patients with congenital heart disease
    Albrecht, Moritz H.
    Varga-Szemes, Akos
    Schoepf, U. Joseph
    Apfaltrer, Georg
    Xu, Jiaqian
    Jin, Kwang-Nam
    Hlavacek, Anthony M.
    Chowdhury, Shahryar M.
    Suranyi, Pal
    Tesche, Christian
    De Cecco, Carlo N.
    Piccini, Davide
    Stuber, Matthias
    Ginami, Giulia
    Vogl, Thomas J.
    Nutting, Arni
    EUROPEAN RADIOLOGY, 2018, 28 (03) : 1267 - 1275
  • [44] Single-Breath-Hold Whole-heart Unenhanced Coronary MRA Using Multi-shot Gradient Echo EPI at 3T: Comparison with Free-breathing Turbo-field-echo Coronary MRA on Healthy Volunteers
    Iyama, Yuji
    Nakaura, Takeshi
    Nagayama, Yasunori
    Oda, Seitaro
    Utsunomiya, Daisuke
    Kidoh, Masafumi
    Yuki, Hideaki
    Hirata, Kenichiro
    Namimoto, Tomohiro
    Kitajima, Mika
    Morita, Kosuke
    Funama, Yoshinori
    Takemura, Atsushi
    Okuaki, Tomoyuki
    Yamashita, Yasuyuki
    MAGNETIC RESONANCE IN MEDICAL SCIENCES, 2018, 17 (02) : 161 - 167
  • [45] Contrast-enhanced magnetic resonance angiography of cerebral arteries - A review
    Parker, DL
    Tsuruda, JS
    Goodrich, KC
    Alexander, AL
    Buswell, HR
    INVESTIGATIVE RADIOLOGY, 1998, 33 (09) : 560 - 572
  • [46] On contrast-enhanced magnetic resonance angiography of the aortoiliac arteries.
    Wikström, J
    ACTA RADIOLOGICA, 2001, 42 : 1 - +
  • [47] CONTRAST-ENHANCED MAGNETIC RESONANCE ANGIOGRAPHY FOR DIAGNOSIS OF PORTOSYSTEMIC SHUNTS IN 10 DOGS
    Bruehschwein, Andreas
    Foltin, Isa
    Flatz, Katharina
    Zoellner, Martin
    Matis, Ulrike
    VETERINARY RADIOLOGY & ULTRASOUND, 2010, 51 (02) : 116 - 121
  • [48] 3.0-T whole-heart coronary magnetic resonance angiography: comparison of gadobenate dimeglumine and gadofosveset trisodium
    Raman, Fabio S.
    Nacif, Marcelo S.
    Cater, George
    Gai, Neville
    Jones, Jacquin
    Li, Debiao
    Sibley, Christopher T.
    Liu, Songtao
    Bluemke, David A.
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2013, 29 (05) : 1085 - 1094
  • [49] Non-Contrast-Enhanced and Contrast-Enhanced Magnetic Resonance Angiography in Living Donor Liver Vascular Anatomy
    Liao, Chien-Chang
    Chen, Meng-Hsiang
    Yu, Chun-Yen
    Tsang, Leung-Chit Leo
    Chen, Chao-Long
    Hsu, Hsien-Wen
    Lim, Wei-Xiong
    Chuang, Yi-Hsuan
    Huang, Po-Hsun
    Cheng, Yu-Fan
    Ou, Hsin-You
    DIAGNOSTICS, 2022, 12 (02)