摘要
Whole-heart coronary MR angiography (MRA) is a promising method for detecting coronary artery disease. However, the imaging time is relatively long (on the order of 10-15 min). Such a long imaging time may result in patient discomfort and compromise the robustness of whole-heart coronary MRA due to increased respiratory and cardiac motion artifacts. The goal of this study was to optimize a gradient echo interleaved echo planar imaging (GRE-EPI) acquisition scheme for reducing the imaging time of contrast-enhanced whole-heart coronary MRA. Numerical simulations and phantom studies were used to optimize the GRE-EPI sequence parameters. Healthy volunteers were scanned with both the proposed GRE-EPI sequence and a 3D TrueFISP sequence for comparison purposes. Slow infusion (0.5 cc/sec) of Gd-DTPA was used to enhance the signal-to-noise ratio (SNR) of the GRE-EPI acquisition. Whole-heart images with the GRE-EPI technique were acquired with a true resolution of 1.0 x 1.1 x 2.0 mm(3) in an average scan time of 4.7 +/- 0.7 min with an average navigator efficiency of 44 +/- 6%. The GRE-EPI acquisition showed excellent delineation of all the major coronary arteries with scan time reduced by a factor of 2 compared with the TrueFISP acquisition. Magn Reson Med 61: 1388-1395, 2009. (C) 2009 Wiley-Liss, Inc.
引用
收藏
页码:1388 / 1395
页数:8
相关论文
共 50 条
  • [21] Sparse 3D contrast-enhanced whole-heart imaging for coronary artery evaluation
    Ansari, Uzair
    Janssen, Sonja
    Baumann, Stefan
    Borggrefe, Martin
    Waldeck, Stephan
    Schoenberg, Stefan
    Papavassiliu, Theano
    Overhoff, Daniel
    HERZ, 2023, 48 (01) : 55 - 63
  • [22] Facilitated acquisition of whole-heart coronary magnetic resonance angiography with visual feedback of respiration status
    Okada, Tomohisa
    Kuhara, Shigehide
    Kanao, Shotaro
    Ninomiya, Ayako
    Sato, Saori
    Kamae, Toshikazu
    Gotoh, Kimio
    Togashi, Kaori
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2009, 25 (04) : 397 - 403
  • [23] Diagnostic performance of non-contrast-enhanced whole-heart magnetic resonance coronary angiography in combination with adenosine stress perfusion cardiac magnetic resonance imaging
    Heer, Tobias
    Reiter, Stephanie
    Hoefling, Berthold
    Pilz, Guenter
    AMERICAN HEART JOURNAL, 2013, 166 (06) : 999 - 1009
  • [24] Whole-heart steady-state free precession coronary artery magnetic resonance angiography
    Weber, OM
    Martin, AJ
    Higgins, CB
    MAGNETIC RESONANCE IN MEDICINE, 2003, 50 (06) : 1223 - 1228
  • [25] Coronary artery angiography and myocardial viability imaging: a 3.0-T contrast-enhanced magnetic resonance coronary artery angiography with Gd-BOPTA
    Yun, Hong
    Jin, Hang
    Yang, Shan
    Huang, Dong
    Chen, Zhang-wei
    Zeng, Meng-su
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2014, 30 (01) : 99 - 108
  • [26] Recent advances in contrast-enhanced magnetic resonance angiography
    Meaney, James F. M.
    Goyen, Mathias
    EUROPEAN RADIOLOGY, 2007, 17 : B2 - B6
  • [27] Contrast-enhanced whole-heart coronary MRA at 3.0T for the evaluation of cardiac venous anatomy
    Ma, Heng
    Tang, Qing
    Yang, Qi
    Bi, Xiaoming
    Li, Han
    Ge, Lan
    Lin, Kai
    Xu, Dong
    Du, Xiangying
    Lu, Jie
    An, Jing
    Jin, Lixin
    Jerecic, Renate
    Li, Kuncheng
    Li, Debiao
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2011, 27 (07) : 1003 - 1009
  • [28] Depiction of reperfused myocardial infarction using contrast-enhanced spin echo and gradient echo magnetic resonance imaging
    Geschwind, JFH
    Saeed, M
    Wendland, MF
    Higgins, CB
    INVESTIGATIVE RADIOLOGY, 1998, 33 (07) : 386 - 392
  • [29] Long-term prognostic value of whole-heart coronary magnetic resonance angiography
    Nakamura, Satoshi
    Ishida, Masaki
    Nakata, Kei
    Ichikawa, Yasutaka
    Takase, Shinichi
    Takafuji, Masafumi
    Ito, Haruno
    Nakamori, Shiro
    Kurita, Tairo
    Dohi, Kaoru
    Sakuma, Hajime
    JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2021, 23 (01)
  • [30] Whole-Heart Coronary Magnetic Resonance Angiography at 1.5 Tesla Does a Blood-Pool Contrast Agent Improve Diagnostic Accuracy?
    Wagner, Moritz
    Roesler, Roberta
    Lembcke, Alexander
    Butler, Craig
    Dewey, Marc
    Laule, Michael
    Huppertz, Alexander
    Schwenke, Carsten
    Warmuth, Carsten
    Rief, Matthias
    Hamm, Bernd
    Taupitz, Matthias
    INVESTIGATIVE RADIOLOGY, 2011, 46 (03) : 152 - 159