Whole-Heart Contrast-Enhanced Coronary Magnetic Resonance Angiography Using Gradient Echo Interleaved EPI

被引:6
作者
Bhat, Himanshu [2 ,3 ]
Zuehlsdorff, Sven [1 ]
Bi, Xiaoming [1 ]
Li, Debiao [2 ,3 ]
机构
[1] Siemens Med Solut USA Inc, Chicago, IL USA
[2] Northwestern Univ, Dept Radiol, Chicago, IL 60611 USA
[3] Northwestern Univ, Dept Biomed Engn, Chicago, IL 60611 USA
基金
美国国家卫生研究院;
关键词
coronary arteries; magnetic resonance angiography; interleaved EPI; contrast media; MR-ANGIOGRAPHY; VOLUME; MOTION; ARTERIES; MINUTES; SCANNER; HUMANS; 3T;
D O I
10.1002/mrm.21963
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Whole-heart coronary MR angiography (MRA) is a promising method for detecting coronary artery disease. However, the imaging time is relatively long (on the order of 10-15 min). Such a long imaging time may result in patient discomfort and compromise the robustness of whole-heart coronary MRA due to increased respiratory and cardiac motion artifacts. The goal of this study was to optimize a gradient echo interleaved echo planar imaging (GRE-EPI) acquisition scheme for reducing the imaging time of contrast-enhanced whole-heart coronary MRA. Numerical simulations and phantom studies were used to optimize the GRE-EPI sequence parameters. Healthy volunteers were scanned with both the proposed GRE-EPI sequence and a 3D TrueFISP sequence for comparison purposes. Slow infusion (0.5 cc/sec) of Gd-DTPA was used to enhance the signal-to-noise ratio (SNR) of the GRE-EPI acquisition. Whole-heart images with the GRE-EPI technique were acquired with a true resolution of 1.0 x 1.1 x 2.0 mm(3) in an average scan time of 4.7 +/- 0.7 min with an average navigator efficiency of 44 +/- 6%. The GRE-EPI acquisition showed excellent delineation of all the major coronary arteries with scan time reduced by a factor of 2 compared with the TrueFISP acquisition. Magn Reson Med 61: 1388-1395, 2009. (C) 2009 Wiley-Liss, Inc.
引用
收藏
页码:1388 / 1395
页数:8
相关论文
共 39 条
[1]  
AHARON S, 2006, P 14 ANN M ISMRM SEA, P365
[2]  
BHAT H, 2008, P 16 ANN M ISMRM TOR, P914
[3]   Whole-heart coronary magnetic resonance angiography at 3 Tesla in 5 minutes with slow infusion of Gd-BOPTA, a high-relaxivity clinical contrast agent [J].
Bi, Xiaoming ;
Carr, James C. ;
Li, Debiao .
MAGNETIC RESONANCE IN MEDICINE, 2007, 58 (01) :1-7
[4]   Coronary arteries at 3.0 T: Contrast-enhanced magnetization-prepared three-dimensional breathhold MR angiography [J].
Bi, XM ;
Li, DB .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2005, 21 (02) :133-139
[5]   CORONARY-ARTERY IMAGING AT 0.5 T USING SEGMENTED 3D ECHO-PLANAR IMAGING [J].
BORNERT, P ;
JENSEN, D .
MAGNETIC RESONANCE IN MEDICINE, 1995, 34 (06) :779-785
[6]  
Botnar RM, 1999, JMRI-J MAGN RESON IM, V10, P821, DOI 10.1002/(SICI)1522-2586(199911)10:5<821::AID-JMRI29>3.0.CO
[7]  
2-7
[8]   CORONARY ANGIOGRAPHY WITH MAGNETIZATION-PREPARED T-2 CONTRAST [J].
BRITTAIN, JH ;
HU, BS ;
WRIGHT, GA ;
MEYER, CH ;
MACOVSKI, A ;
NISHIMURA, DG .
MAGNETIC RESONANCE IN MEDICINE, 1995, 33 (05) :689-696
[9]   Gadodiamide-associated nephrogenic systemic fibrosis: Why radiologists should be concerned [J].
Broome, Dale R. ;
Girguis, Mark S. ;
Baron, Pedro W. ;
Cottrell, Alfred C. ;
Kjellin, Ingrid ;
Kirk, Gerald A. .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2007, 188 (02) :586-592
[10]   IMAGE-RECONSTRUCTION FOR ECHO PLANAR IMAGING WITH NONEQUIDISTANT KAPPA-SPACE SAMPLING [J].
BRUDER, H ;
FISCHER, H ;
REINFELDER, HE ;
SCHMITT, F .