Repair of Segmental Long Bone Defect in a Rabbit Radius Nonunion Model: Comparison of Cylindrical Porous Titanium and Hydroxyapatite Scaffolds

被引:14
作者
Zhang, Ming [1 ]
Wang, Guang-lin [1 ]
Zhang, Hong-fang [1 ]
Hu, Xu-dong [1 ]
Shi, Xiao-yuan [1 ]
Li, Sen [1 ]
Lin, Wei [2 ]
机构
[1] Sichuan Univ, West China Hosp, Dept Orthopaed Surg, Chengdu 610041, Sichuan, Peoples R China
[2] Sichuan Univ, West China Hosp 2, Dept Gynecol & Obstet, Chengdu 610041, Sichuan, Peoples R China
关键词
Porous titanium; Long bone repair; Osseointegration; Nonunion model; CALCIUM-PHOSPHATE CERAMICS; ATROPHIC NONUNION; ORTHOPEDIC APPLICATIONS; MECHANICAL-PROPERTIES; TRICALCIUM PHOSPHATE; BIOACTIVE TITANIUM; GRAFT SUBSTITUTES; IMPLANTS; STRESS; GROWTH;
D O I
10.1111/aor.12208
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
A segmental long bone defect in a rabbit radius nonunion model was repaired using cylindrical porous titanium (Ti) and hydroxyapatite (HA) scaffolds. Each scaffold was produced using the same method, namely, a slurry foaming method. Repairing ability was characterized using x-radiographic score 12 and 24 weeks postprocedure; failure load of the radius-ulna construct, under three-point bending, 12 weeks postprocedure; and the percentage of newly formed bone within the implant, 12 and 24 weeks after postprocedure. For each of these parameters, the difference in the results when porous Ti scaffold was used compared with when HA scaffolds were used was not significant; both porous scaffolds showed excellent repairing ability. Because the trabecular bone is a porous tissue, the interconnected porous scaffolds have the advantages of natural bone, and vasculature can grow into the porous structure to accelerate the osteoconduction and osteointegration between the implant and bone. The porous Ti scaffold not only enhanced the bone repair process, similar to porous HA scaffolds, but also has superior biomechanical properties. The present results suggest that porous Ti scaffolds may have promise for use in the clinical setting.
引用
收藏
页码:493 / 502
页数:10
相关论文
共 72 条
  • [1] Al Ruhaimi KA, 2001, INT J ORAL MAX IMPL, V16, P105
  • [2] [Anonymous], 1971, COMPATIBILITY BIOCER
  • [3] Refining animal models in fracture research:: seeking consensus in optimising both animal welfare and scientific validity for appropriate biomedical use
    Auer, Jorg A.
    Goodship, Allen
    Arnoczky, Steven
    Pearce, Simon
    Price, Jill
    Claes, Lutz
    Von Rechenberg, Brigitte
    Hofmann-Amtenbrinck, Margarethe
    Schneider, Erich
    Mueller-Terpitz, R.
    Thiele, F.
    Rippe, Klaus-Peter
    Grainger, David W.
    [J]. BMC MUSCULOSKELETAL DISORDERS, 2007, 8 (1)
  • [4] Osteointegration of biomimetic apatite coating applied onto dense and porous metal implants in femurs of goats
    Barrère, F
    van der Valk, CM
    Meijer, G
    Dalmeijer, RAJ
    de Groot, K
    Layrolle, P
    [J]. JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART B-APPLIED BIOMATERIALS, 2003, 67B (01) : 655 - 665
  • [5] TREATMENT OF UNUNITED TIBIAL DIAPHYSEAL FRACTURES WITH PULSING ELECTROMAGNETIC-FIELDS
    BASSETT, CAL
    MITCHELL, SN
    GASTON, SR
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1981, 63 (04) : 511 - 523
  • [6] Blokhuis TJ, 2000, J BIOMED MATER RES, V51, P369, DOI 10.1002/1097-4636(20000905)51:3<369::AID-JBM10>3.0.CO
  • [7] 2-J
  • [8] BOBYN JD, 1992, CLIN ORTHOP RELAT R, P79
  • [9] Use of bone morphogenetic protein-2 in the rabbit ulnar nonunion model
    Bostrom, M
    Lane, JM
    Tomin, E
    Browne, M
    Berberian, W
    Turek, T
    Smith, J
    Wozney, J
    Schildhauer, T
    [J]. CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 1996, (327) : 272 - 282
  • [10] Brentel Aline Scalone, 2006, J. Appl. Oral Sci., V14, P213, DOI 10.1590/S1678-77572006000300013