Computed tomographic evaluation of the proximal femur: A predictive classification in displaced femoral neck fracture management

被引:6
作者
Magu, Narender Kumar [1 ]
Magu, Sarita [2 ]
Rohilla, Rajesh Kumar [1 ]
Batra, Amit [1 ]
Jaipuria, Abhishek [1 ]
Singh, Amanpreet [1 ]
机构
[1] PGIMS, Dept Orthopaed, Rohtak 124001, Haryana, India
[2] PGIMS, Dept Radiol, Rohtak 124001, Haryana, India
关键词
Lag screw; neck of femur; valgus osteotomy MeSH terms: Osteotomy; femoral; neck fracture; computed tomographic; bone screws; TOTAL HIP-REPLACEMENT; NAIL-PLATE FIXATION; INTERNAL-FIXATION; SUBCAPITAL FRACTURES; INTERTROCHANTERIC OSTEOTOMY; RANDOMIZED-TRIAL; HOOK-PINS; OSTEOSYNTHESIS; ARTHROPLASTY; HEMIARTHROPLASTY;
D O I
10.4103/0019-5413.139857
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Femoral neck fracture is truly an enigma due to the high incidence of avascular necrosis and nonunion. Different methods have been described to determine the size of the femoral head fragment, as a small head has been said to be associated with poor outcome and nonunion due to inadequate implant purchase in the proximal fragment. These methods were two dimensional and were affected by radiography techniques, therefore did not determine true head size. Computed tomography (CT) is an important option to measure true head size as images can be obtained in three dimensions. Henceforth, we subjected patients to CT scan of hip in cases with displaced fracture neck of femur. The study aims to define the term "small head or inadequate size femoral head" objectively for its prognostic significance. Materials and Methods: 70 cases of displaced femoral neck fractures underwent CT scan preoperatively for proximal femoral geometric measurements of both hips. Dual energy X-ray absorptiometry scan was done in all cases. Patients were treated with either intertrochanteric osteotomy or lag screw osteosynthesis based on the size of the head fragment on plain radiographs. Results: The average femoral head fragment volume was 57 cu cm (range 28.3-84.91 cu cm; standard deviation 14 cu cm). Proximal fragment volume of > 43 cu cm was termed adequate size (type I) and of %43 cu cm as small femoral head (type II). Fractures which united (n = 54) had a relatively large average head size (59 cu cm) when compared to fractures that did not (n = 16), which had a small average head size (49 cu cm) and this difference was statistically significant. In type I fractures union rate was comparable in both osteotomy and lag screw groups (P > 0.05). Lag screw fixation failed invariably, while osteotomy showed good results in type II fractures (P < 0.05). Conclusion: Computed tomography scan of the proximal femur is advisable for measuring true size of head fragment. An objective classification based on the femoral head size (type I and type II) is proposed. Osteosynthesis should be the preferred method of treatment in type I and osteotomy or prosthetic replacement is the method of choice for type II femoral neck fractures.
引用
收藏
页码:476 / 483
页数:8
相关论文
共 37 条
[1]  
ALHO A, 1992, ACTA ORTHOP SCAND, V63, P639
[2]   SUBCAPITAL FRACTURES OF FEMUR [J].
BARNES, R ;
BROWN, JT ;
GARDEN, RS ;
NICOLL, EA .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1976, 58 (01) :2-24
[3]   Operative management of displaced femoral neck fractures in elderly patients - An international survey [J].
Bhandari, M ;
Devereaux, PJ ;
Tornetta, P ;
Swiontkowski, MF ;
Berry, DJ ;
Haidukewych, G ;
Schemitsch, EH ;
Hanson, BP ;
Koval, K ;
Dirschl, D ;
Leece, P ;
Keel, M ;
Petrisor, B ;
Heetveld, M ;
Guyatt, GH .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2005, 87A (09) :2122-2130
[4]   Outcome of undisplaced and moderately displaced femoral neck fractures -: A prospective study of 466 patients treated by internal fixation [J].
Bjorgul, Kristian ;
Reikeras, Olav .
ACTA ORTHOPAEDICA, 2007, 78 (04) :498-504
[5]   Comparison of internal fixation with total hip replacement for displaced femoral neck fractures -: Randomized, controlled trial performed at four years [J].
Blomfeldt, R ;
Törnkvist, H ;
Ponzer, S ;
Söderqvist, A ;
Tidermark, J .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2005, 87A (08) :1680-1688
[6]  
BRAY TJ, 1988, CLIN ORTHOP RELAT R, P127
[7]   TRANSCERVICAL FEMORAL FRACTURE - A REVIEW OF 195 PATIENTS TREATED BY SLIDING NAIL-PLATE FIXATION [J].
BROWN, JT ;
ABRAMI, G .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1964, 46 (04) :648-663
[8]   FAILURE OF SLIDING NAIL-PLATE FIXATION IN SUBCAPITAL FRACTURES OF THE FEMORAL-NECK [J].
BROWN, TIS ;
COURTBROWN, C .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1979, 61 (03) :342-346
[9]   FUNCTIONAL RESULTS OF HIP ARTHROPLASTY WITH ACRYLIC PROSTHESIS [J].
DAUBIGNE, RM ;
POSTEL, M .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1954, 36-A (03) :451-475
[10]   Fixation of femoral neck fracture - A randomized 2-year follow-up study of hook pins and sliding screw plate in 222 patients [J].
Elmerson, S ;
Sjostedt, A ;
Zetterberg, C .
ACTA ORTHOPAEDICA SCANDINAVICA, 1995, 66 (06) :507-510