Reproducibility of an Isokinetic Strength-Testing Protocol of the Knee and Ankle in Older Adults

被引:133
作者
Hartmann, Antonia [1 ,4 ]
Knols, Ruud [2 ,3 ]
Murer, Kurt [1 ]
de Bruin, Eling D. [1 ,2 ,3 ]
机构
[1] Univ Zurich Hosp, Inst Human Movement Sci & Sport, ETH, CH-8091 Zurich, Switzerland
[2] Univ Zurich Hosp, Dept Rheumatol, CH-8091 Zurich, Switzerland
[3] Univ Zurich Hosp, Inst Med Phys, CH-8091 Zurich, Switzerland
[4] Maastricht Univ, Care & Publ Hlth Res Inst, Maastricht, Netherlands
关键词
Isokinetic test protocols; Isokinetic dynamometers; Protocol reproducibility; Knee/ankle contractions; MUSCLE STRENGTH; RELIABILITY; WOMEN; POWER; MEN; EXTENSION; FLEXION; FORCE;
D O I
10.1159/000172832
中图分类号
R592 [老年病学]; C [社会科学总论];
学科分类号
03 ; 0303 ; 100203 ;
摘要
Background: Muscle power assessed by isokinetic dynamometers has the potential for playing an important role in investigating functional status in older subjects. Researchers and clinicians are interested in the reliability of isokinetic test protocols for the confidential assessment of status, as this affects the interpretation of the results of an intervention program. Objective: The current study investigated the inter- and intrarater reliability of an isokinetic strength-testing protocol of the knee and ankle preceded by a familiarization session. Methods: Twenty-four independently living elderly subjects (6 males, 18 females, mean age 71.2 +/- 5.5 years) were assessed 3 times in two test sessions. The main outcomes were the intraclass correlation coefficient, standard error of measurements (SEM) and ratio of limits of agreement (RLOA) for isokinetic knee and ankle contractions, as measured with the Biodex System 3. Results: The intraclass correlation coefficients of the isokinetic variables varied from 0.81 to 0.99 representing 'good' to 'very good' reliability. Most SEM and RLOA indexes represented acceptable agreement which varied from 6 to 13 and 18 to 37%, respectively. Nonacceptable agreement was found for ankle plantar flexion with SEMs that varied from 14 to 17% and RLOAs from 39 to 48%. Conclusion: The results of this study demonstrate that the Biodex System 3 is a reliable device when used for elderly living independently. The ability of the device to determine a real change in isokinetic ankle and knee contractions is better on a group level than on an individual level. The Biodex System 3 can be employed with confidence in studies to determine the effect of exercise intervention programs on physical activity. Copyright (C) 2008 S. Karger AG, Basel
引用
收藏
页码:259 / 268
页数:10
相关论文
共 26 条
[1]   Statistical methods for assessing measurement error (reliability) in variables relevant to sports medicine [J].
Atkinson, G ;
Nevill, AM .
SPORTS MEDICINE, 1998, 26 (04) :217-238
[2]   LEG EXTENSOR POWER AND FUNCTIONAL PERFORMANCE IN VERY OLD MEN AND WOMEN [J].
BASSEY, EJ ;
FIATARONE, MA ;
ONEILL, EF ;
KELLY, M ;
EVANS, WJ ;
LIPSITZ, LA .
CLINICAL SCIENCE, 1992, 82 (03) :321-327
[3]   Measuring agreement in method comparison studies [J].
Bland, JM ;
Altman, DG .
STATISTICAL METHODS IN MEDICAL RESEARCH, 1999, 8 (02) :135-160
[4]  
Capranica L, 1998, J SPORT MED PHYS FIT, V38, P169
[5]   Motor skill learning of concentric and eccentric isokinetic movements in older adults [J].
Connelly, DM ;
Carnahan, H ;
Vandervoort, AA .
EXPERIMENTAL AGING RESEARCH, 2000, 26 (03) :209-228
[6]   Reliability and validity of the Biodex system 3 pro isokinetic dynamometer velocity, torque and position measurements [J].
Drouin, JM ;
Valovich-mcLeod, TC ;
Shultz, SJ ;
Gansneder, BM ;
Perrin, DH .
EUROPEAN JOURNAL OF APPLIED PHYSIOLOGY, 2004, 91 (01) :22-29
[7]  
Dvir Z., 2004, ISOKINETICS MUSCLE T
[8]   Strength and power changes of the human plantar flexors and knee extensors in response to resistance training in old age [J].
Ferri, A ;
Scaglioni, G ;
Pousson, M ;
Capodaglio, P ;
Van Hoecke, J ;
Narici, MV .
ACTA PHYSIOLOGICA SCANDINAVICA, 2003, 177 (01) :69-78
[9]   What change in isokinetic knee muscle strength can be detected in men and women with hemiparesis after stroke? [J].
Flansbjer, UB ;
Holmbäck, AM ;
Downham, D ;
Lexell, J .
CLINICAL REHABILITATION, 2005, 19 (05) :514-522
[10]  
FRONTERA WR, 1993, ARCH PHYS MED REHAB, V74, P1181