The value of 99mTc-MAA SPECT/CT for lung shunt estimation in 90Y radioembolization: a phantom and patient study

被引:44
作者
Allred, Jonathan D. [1 ]
Niedbala, Jeremy [2 ]
Mikell, Justin K. [3 ]
Owen, Dawn [3 ]
Frey, Kirk A. [2 ]
Dewaraja, Yuni K. [2 ]
机构
[1] Nottingham Univ Hosp NHS Trust, Radiotherapy Phys, Nottingham, England
[2] Univ Michigan, Dept Radiol, 1301 Catherine,2276 Med Sci 1,SPC 5610, Ann Arbor, MI 48109 USA
[3] Univ Michigan, Dept Radiat Oncol, Ann Arbor, MI 48109 USA
关键词
Y-90; PET/CT; Transarterial radioembolization (TARE); Lung shunt; Tc-99m-MAA SPECT/CT; BREMSSTRAHLUNG SPECT/CT; QUANTITATIVE-EVALUATION; RECONSTRUCTION; DOSIMETRY; MICROSPHERES; CANCER; PET/CT;
D O I
10.1186/s13550-018-0402-8
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background: A major toxicity concern in radioembolization therapy of hepatic malignancies is radiation-induced pneumonitis and sclerosis due to hepatopulmonary shunting of Y-90 microspheres. Currently, Tc-99m macroaggregated albumin (Tc-99m-MAA) imaging is used to estimate the lung shunt fraction (LSF) prior to treatment. The aim of this study was to evaluate the accuracy/precision of LSF estimated from Tc-99m planar and SPECT/CT phantom imaging, and within this context, to compare the corresponding LSF and lung-absorbed dose values from Tc-99m-MAA patient studies. Additionally, LSFs from pre- and post-therapy imaging were compared. Results: A liver/lung torso phantom filled with Tc-99m to achieve three lung shunt values was scanned by planar and SPECT/CT imaging with repeat acquisitions to assess accuracy and precision. To facilitate processing of patient data, a workflow that relies on SPECT and CT-based auto-contouring to define liver and lung volumes for the LSF calculation was implemented. Planar imaging-based LSF estimates for 40 patients, obtained from their medical records, were retrospectively compared with SPECT/CT imaging-based calculations with attenuation and scatter correction. Additionally, in a subset of 20 patients, the pre-therapy estimates were compared with Y-90 PET/CT-based measurements. In the phantom study, improved accuracy in LSF estimation was achieved using SPECT/CT with attenuation and scatter correction (within 13% of the true value) compared with planar imaging (up to 44% overestimation). The results in patients showed a similar trend with planar imaging significantly overestimating LSF compared to SPECT/CT. There was no correlation between lung shunt estimates and the delay between Tc-99m-MAA administration and scanning, but off-target extra hepatic uptake tended to be more likely in patients with a longer delay. The mean lung absorbed dose predictions for the 28 patients who underwent therapy was 9.3 Gy (range 1.3-29.4) for planar imaging and 3.2 Gy (range 0.4-13.4) for SPECT/CT. For the patients with post-therapy imaging, the mean LSF from Y-90 PET/CT was 1.0%, (range 0.32.8). This value was not significantly different from the mean LSF estimate from Tc-99m-MAA SPECT/CT (mean 1.0%, range 0.4-1.6; p = 0.968), but was significantly lower than the mean LSF estimate based on planar imaging (mean 4.1%, range 1.2-15.0; p = 0.0002). Conclusions: The improved accuracy demonstrated by the phantom study, agreement with Y-90 PET/CT in patient studies, and the practicality of using auto-contouring for liver/lung definition suggests that Tc-99m-MAA SPECT/CT with scatter and attenuation corrections should be used for lung shunt estimation prior to radioembolization.
引用
收藏
页数:12
相关论文
共 22 条
[1]   Biodistribution of 99mTc-MAA on SPECT/CT performed for 90Y-radioembolization therapy planning: a pictorial review [J].
Bailey, Jason J. ;
Dewaraja, Y. ;
Hubers, D. ;
Srinivasa, R. ;
Frey, K. A. .
CLINICAL AND TRANSLATIONAL IMAGING, 2017, 5 (05) :473-485
[2]  
De Gersem R, 2013, CLIN NUCL MED, V38, P940, DOI 10.1097/RLU.0000000000000241
[3]  
Dewaraja YK, 2015, EUR J NUCL MED MOL I, V42, pS156
[4]   3-D Monte Carlo-based scatter compensation in quantitative I-131SPECT reconstruction [J].
Dewaraja, YK ;
Ljungberg, M ;
Fessler, JA .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2006, 53 (01) :181-188
[5]   Improved quantitative 90Y bremsstrahlung SPECT/CT reconstruction with Monte Carlo scatter modeling [J].
Dewaraja, Yuni K. ;
Chun, Se Young ;
Srinivasa, Ravi N. ;
Kaza, Ravi K. ;
Cuneo, Kyle C. ;
Majdalany, Bill S. ;
Novelli, Paula M. ;
Ljungberg, Michael ;
Fessler, Jeffrey A. .
MEDICAL PHYSICS, 2017, 44 (12) :6364-6376
[6]   Recommendations of the American Association of Physicists in Medicine on dosimetry, imaging, and quality assurance procedures for 90Y microsphere brachytherapy in the treatment of hepatic malignancies [J].
Dezarn, William A. ;
Cessna, Jeffery T. ;
DeWerd, Larry A. ;
Feng, Wenzheng ;
Gates, Vanessa L. ;
Halama, James ;
Kennedy, Andrew S. ;
Nag, Subir ;
Sarfaraz, Mehrdad ;
Sehgal, Varun ;
Selwyn, Reed ;
Stabin, Michael G. ;
Thomadsen, Bruce R. ;
Williams, Lawrence E. ;
Salem, Riad .
MEDICAL PHYSICS, 2011, 38 (08) :4824-4845
[7]   A Prospective Study of Quantitative SPECT/CT for Evaluation of Lung Shunt Fraction Before SIRT of Liver Tumors [J].
Dittmann, Helmut ;
Kopp, Daniel ;
Kupferschlaeger, Juergen ;
Feil, Diana ;
Groezinger, Gerd ;
Syha, Roland ;
Weissinger, Matthias ;
la Fougere, Christian .
JOURNAL OF NUCLEAR MEDICINE, 2018, 59 (09) :1366-1372
[8]   Selective internal radiation therapy compared with sorafenib for hepatocellular carcinoma with portal vein thrombosis [J].
Edeline, Julien ;
Crouzet, Laurence ;
Campillo-Gimenez, Boris ;
Rolland, Yan ;
Pracht, Marc ;
Guillygomarc'h, Anne ;
Boudjema, Karim ;
Lenoir, Laurence ;
Adhoute, Xavier ;
Rohou, Tanguy ;
Boucher, Eveline ;
Clement, Bruno ;
Blanc, Jean-Frederic ;
Garin, Etienne .
EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2016, 43 (04) :635-643
[9]   99mTc-MAA overestimates the absorbed dose to the lungs in radioembolization: a quantitative evaluation in patients treated with 166Ho-microspheres [J].
Elschot, Mattijs ;
Nijsen, Johannes F. W. ;
Lam, Marnix G. E. H. ;
Smits, Maarten L. J. ;
Prince, Jip F. ;
Viergever, Max A. ;
van den Bosch, Maurice A. A. J. ;
Zonnenberg, Bernard A. ;
de Jong, Hugo W. A. M. .
EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2014, 41 (10) :1965-1975
[10]   Quantitative Monte Carlo-Based 90Y SPECT Reconstruction [J].
Elschot, Mattijs ;
Lam, Marnix G. E. H. ;
van den Bosch, Maurice A. A. J. ;
Viergever, Max A. ;
de Jong, Hugo W. A. M. .
JOURNAL OF NUCLEAR MEDICINE, 2013, 54 (09) :1557-1563