Biomechanical Comparison of Polyaxial and Uniaxial Locking Plate Fixation in a Proximal Tibial Gap Model

被引:46
作者
Cullen, Aaron B. [1 ]
Curtiss, Shane [1 ]
Lee, Mark A. [1 ]
机构
[1] Univ Calif Davis, Med Ctr, Dept Orthopaed Surg, Sacramento, CA 95817 USA
关键词
biomechanics; locked plates; proximal tibial fractures; polyaxial fixation; tibia; LESS INVASIVE STABILIZATION; INTERNAL-FIXATION; FRACTURES; SYSTEM; EXPERIENCE; DESIGN; JOINT; LISS; GAIT;
D O I
10.1097/QAI.0b013e3181a25368
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Objectives: Lateral locked plating for proximal tibial fractures with metaphyseal disruption provides a biomechanically stable and biologically favorable alternative to conventional medial/lateral plate fixation. New polyaxial screw technology incorporates expanding screw bushings, allowing variable angle screw placement, while providing angular stability. We hypothesize that polyaxial locking plates will exhibit comparable stiffness, strength to failure, and resistance to plastic deformation to conventional locking plates in a proximal tibial gap model. Methods: We stabilized extra-articular metaphyseal gap osteotomies in synthetic composite tibiae with dual medial and lateral plating, Less Invasive Stabilization System (LISS) plates, 4.5-mm proximal tibial lateral locking plates with (LP+) and without (LP-) angled screws, and 4.5-mm polyaxial locking plates with (PA+) and without (PA-) angled screws. All were tested with cyclic, ramped, and axial loading to failure. Results: No plates demonstrated screw failure before plate failure. Dual-plate constructs did not fail. All lateral plates failed at the osteotomy. LP- failed at low load. PA+ was significantly stiffer (165 +/- 17 N/mm) with greater load to failure (711 +/- 23 N) than all other constructs (PA-: 56 +/- 6 N/mm, 617 +/- 33 N; LP+: 137 +/- 23 N/mm, 488 +/- 39 N; LISS: 76 +/- 5 N/mm, 656 +/- 39 N). PA+ had significantly less plastic deformation (12.1 +/- 0.8 min) than LP+ (13.4 +/- 3.7 mm), but more than PA- (5.8 +/- 1.2 mm) and LISS (3.9 +/- 0.6 mm). PA- did not differ significantly from LISS in any parameter. Conclusions: This study demonstrates that this unique polyaxial locking plate mechanism, when tested in various constructs, exhibits similar biomechanical performance regarding stiffness, strength to failure, and resistance to plastic deformation when compared with uniaxial locking plates. The polyaxial locking plate with an angled screw was stiffest and had the greatest load to failure. The polyaxial locking plate alone tested similar to the LISS. In addition, the benefit of the angled screw for biomechanical stability is demonstrated.
引用
收藏
页码:507 / 513
页数:7
相关论文
共 27 条
  • [1] Experimental model of tibial plateau fracture for biomechanical testing
    Ali, Ahmad M.
    Saleh, Michael
    Bolongaro, Stefano
    Yang, Lang
    [J]. JOURNAL OF BIOMECHANICS, 2006, 39 (07) : 1355 - 1360
  • [2] Functional outcomes of severe bicondylar plateau fractures treated with dual incisions and medial and lateral plates
    Barei, David P.
    Nork, Sean E.
    Mills, William J.
    Coles, Chad P.
    Henley, M. Bradford
    Benirschke, Stephen K.
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2006, 88A (08) : 1713 - 1721
  • [3] Complications associated with internal fixation of high-energy bicondylar tibial plateau fractures utilizing a two-incision technique
    Barei, DP
    Nork, SE
    Mills, WJ
    Henley, MB
    Benirschke, SK
    [J]. JOURNAL OF ORTHOPAEDIC TRAUMA, 2004, 18 (10) : 649 - 657
  • [4] Treatment of proximal tibia fractures using the Less Invasive Stabilization System - Surgical experience and early clinical results in 77 fractures
    Cole, PA
    Zlowodzki, M
    Kregor, PJ
    [J]. JOURNAL OF ORTHOPAEDIC TRAUMA, 2004, 18 (08) : 528 - 535
  • [5] Less Invasive Stabilization System (LISS) for fractures of the proximal tibia: indications, surgical technique and preliminary results of the UMC clinical trial
    Cole, PA
    Zlowodzki, M
    Kregor, PJ
    [J]. INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2003, 34 : S16 - S29
  • [6] Mechanical validation of whole bone composite femur models
    Cristofolini, L
    Viceconti, M
    Cappello, A
    Toni, A
    [J]. JOURNAL OF BIOMECHANICS, 1996, 29 (04) : 525 - 535
  • [7] Treatment of complex tibial plateau fractures using the less invasive stabilization system plate: Clinical experience and a laboratory comparison with double plating
    Egol, KA
    Su, E
    Tejwani, NC
    Sims, SH
    Kummer, FJ
    Koval, KJ
    [J]. JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE, 2004, 57 (02): : 340 - 346
  • [8] LISS PLT: Design, mechanical and biomechanical characteristics
    Goesling, T
    Frenk, A
    Appenzeller, A
    Garapati, R
    Marti, A
    Krettek, C
    [J]. INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2003, 34 : S11 - S15
  • [9] González YH, 2007, ACTA ORTHOP BELG, V73, P60
  • [10] Gösling T, 2004, J ORTHOP TRAUMA, V18, P546