In vitro Biomechanical Analysis of Proximal Phalangeal Osteotomy Fixation

被引:2
作者
Deschuyffeleer, Sten [1 ]
Duerinckx, Joris [1 ]
Caekebeke, Pieter [1 ]
机构
[1] Ziekenhuis Oost Limburg, Dept Orthopaed Surg & Traumatol, Limburg, Belgium
关键词
corrective osteotomy; proximal; phalanx; intramedullary screw; plate; FRACTURES;
D O I
10.1055/s-0040-1721409
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background Corrective osteotomies of the proximal phalanx are typically stabilized with plate and screws. Although intramedullary headless screws form an alternative fixation method in the treatment of acute phalangeal fractures, reports about fixation of opening wedge corrective osteotomies with these implants are lacking. Objective The goal of the present study was to biomechanically compare the failure force of both fixation methods for this specific indication. Methods Twenty-four cadaver phalanges were equally distributed between apex volar and apex lateral opening wedge osteotomy groups. In each group, half of the osteotomies were fixed with a 1.3-mm dorsal locking plate, the other half with a 2.4-mm intramedullary headless screw. A three-point bending test was performed. Results The mean maximal failure force after apex lateral osteotomy was 178.4N for the plate-screw construct and 144.0N after intramedullary headless screw fixation. After apex volar osteotomy, mean maximal force was 237.6N in the plate-screw group and 160.9N in the intramedullary headless screw group. Mean stiffness after apex lateral osteotomy was 63.3N/mm in the plate-screw group, and 55.9N/mm in the intramedullary headless screw group. Mean stiffness after apex volar osteotomy was 197.5N/mm and 60.0N/mm for the plate-screw and intramedullary headless screw group, respectively. Conclusion For apex volar osteotomies, dorsally applied angular stable plate and screws provide significantly stronger fixation than intramedullary headless screws. For apex lateral osteotomies, fixation force is comparable. Clinical relevance These data are useful when considering fixation of opening wedge osteotomies with intramedullary screws.
引用
收藏
页码:154 / 157
页数:4
相关论文
共 50 条
  • [41] Biomechanical analysis of 3 fixation techniques in rabbit radius and humerus bones
    Davolt, Meghan L.
    Davis, Ella
    McCleery, Brynn
    Davis, Garrett
    CANADIAN VETERINARY JOURNAL-REVUE VETERINAIRE CANADIENNE, 2022, 63 (05): : 521 - 527
  • [42] Supramalleolar Osteotomy: A Comparison of Fixation Methods
    de Roode, Carolien P.
    Hung, Man
    Stevens, Peter M.
    JOURNAL OF PEDIATRIC ORTHOPAEDICS, 2013, 33 (06) : 672 - 677
  • [43] Biomechanical analysis of locked and non-locked plate fixation of the clavicle
    Little, K. J.
    Riches, P. E.
    Fazzi, U. G.
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2012, 43 (06): : 921 - 925
  • [44] Craniocervical Fixation With Occipital Condyle Screws Biomechanical Analysis of a Novel Technique
    Uribe, Juan S.
    Ramos, Edwin
    Youssef, A. Samy
    Levine, Nick
    Turner, Alexander W. L.
    Johnson, Wesley M.
    Vale, Fernando L.
    SPINE, 2010, 35 (09) : 931 - 938
  • [45] Supplemental medial small fragment fixation adds stability to distal femur fixation: A biomechanical study
    Goodnough, L. Henry
    Salazar, Brett P.
    Chen, Michael J.
    Storaci, Hunter
    Guzman, Robert
    Heffner, Michael
    Tam, Kaysie
    DeBaun, Malcolm R.
    Gardner, Michael J.
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2021, 52 (07): : 1670 - 1672
  • [46] An original method of simulating the articular cartilage in the context of in vitro biomechanical studies investigating the proximal femur
    Gheorghevici, Teodor Stefan
    Carata, Eugen
    Sirbu, Paul-Dan
    Alexa, Ovidiu
    Poroh, Manuela-Gabi
    Filip, Alexandru
    Forna, Norin
    Puha, Bogdan
    EXPERIMENTAL AND THERAPEUTIC MEDICINE, 2022, 23 (03)
  • [47] Marked Resorption of the Thumb Proximal Phalanx Following Open Reduction and K-Wire Fixation of a Phalangeal Neck Fracture in a Child: Case Report
    Al-Qattan, Mohammad M.
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2015, 40 (04): : 688 - 691
  • [48] Biomechanical Evaluation of an Anterior Upper Thoracic Plate Fixation System: An In Vitro Human Cadaveric Study
    Xiong, Chunxiang
    Luo, Juli
    Yin, Dong
    Zhan, Xinli
    Liu, Huijiang
    WORLD NEUROSURGERY, 2019, 124 : E503 - E509
  • [49] Is the magnesium screw as stable as the titanium screw in the fixation of first metatarsal distal chevron osteotomy? A comparative biomechanical study on sawbones models
    Sahin, Adem
    Gulabi, Deniz
    Buyukdogan, Halil
    Agar, Anil
    Kilic, Bulent
    Mutlu, Ibrahim
    Erturk, Cemil
    JOURNAL OF ORTHOPAEDIC SURGERY, 2021, 29 (03)
  • [50] Comparing treatment of proximal phalangeal fractures with intramedullary screws versus plating
    Silins, Kaspars
    Turkmen, Tutku
    Vogelin, Esther
    Haug, Luzian C. P.
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2023, 143 (03) : 1699 - 1706