In vitro Biomechanical Analysis of Proximal Phalangeal Osteotomy Fixation

被引:2
作者
Deschuyffeleer, Sten [1 ]
Duerinckx, Joris [1 ]
Caekebeke, Pieter [1 ]
机构
[1] Ziekenhuis Oost Limburg, Dept Orthopaed Surg & Traumatol, Limburg, Belgium
关键词
corrective osteotomy; proximal; phalanx; intramedullary screw; plate; FRACTURES;
D O I
10.1055/s-0040-1721409
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background Corrective osteotomies of the proximal phalanx are typically stabilized with plate and screws. Although intramedullary headless screws form an alternative fixation method in the treatment of acute phalangeal fractures, reports about fixation of opening wedge corrective osteotomies with these implants are lacking. Objective The goal of the present study was to biomechanically compare the failure force of both fixation methods for this specific indication. Methods Twenty-four cadaver phalanges were equally distributed between apex volar and apex lateral opening wedge osteotomy groups. In each group, half of the osteotomies were fixed with a 1.3-mm dorsal locking plate, the other half with a 2.4-mm intramedullary headless screw. A three-point bending test was performed. Results The mean maximal failure force after apex lateral osteotomy was 178.4N for the plate-screw construct and 144.0N after intramedullary headless screw fixation. After apex volar osteotomy, mean maximal force was 237.6N in the plate-screw group and 160.9N in the intramedullary headless screw group. Mean stiffness after apex lateral osteotomy was 63.3N/mm in the plate-screw group, and 55.9N/mm in the intramedullary headless screw group. Mean stiffness after apex volar osteotomy was 197.5N/mm and 60.0N/mm for the plate-screw and intramedullary headless screw group, respectively. Conclusion For apex volar osteotomies, dorsally applied angular stable plate and screws provide significantly stronger fixation than intramedullary headless screws. For apex lateral osteotomies, fixation force is comparable. Clinical relevance These data are useful when considering fixation of opening wedge osteotomies with intramedullary screws.
引用
收藏
页码:154 / 157
页数:4
相关论文
共 50 条
  • [21] Biomechanical Comparison of Polyaxial and Uniaxial Locking Plate Fixation in a Proximal Tibial Gap Model
    Cullen, Aaron B.
    Curtiss, Shane
    Lee, Mark A.
    JOURNAL OF ORTHOPAEDIC TRAUMA, 2009, 23 (07) : 507 - 513
  • [22] Intra- and Extra-Articular Double-Level Osteotomy for Pediatric Malunited Proximal Phalangeal Fracture: A Case Report
    Akezuma, Hirotaka
    Kawasaki, Keikichi
    Okano, Ichiro
    Kubo, Kazutoshi
    Kudo, Yoshifumi
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2024, 16 (08)
  • [23] Enhancing biomechanical outcomes in proximal femoral osteotomy through optimised blade plate sizing: A neuromusculoskeletal-informed finite element analysis
    Eghan-Acquah, Emmanuel
    Bavil, Alireza Y.
    Bade, David
    Barzan, Martina
    Nasseri, Azadeh
    Saxby, David J.
    Feih, Stefanie
    Carty, Christopher P.
    COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE, 2024, 257
  • [24] Combined proximal tibial osteotomy for varus osteoarthritis of the knee: Biomechanical tests and finite-element analyses
    Ji, Weiping
    Luo, Congfeng
    Zhan, Shi
    Zhan, Yu
    Xie, Xuetao
    Zhang, Binbin
    KNEE, 2020, 27 (03) : 863 - 870
  • [25] Ex vivo biomechanical comparison of four Center of Rotation Angulation Based Leveling Osteotomy fixation methods
    Whitney, Melody E.
    Butler, James R.
    Dycus, David L.
    Teer, Landon B.
    Elder, Steve H.
    Priddy, Lauren B.
    Wills, Robert W.
    VETERINARY SURGERY, 2022, 51 (01) : 157 - 162
  • [26] Biomechanical Analysis of Fixation of Middle Third Fractures of the Clavicle
    Drosdowech, Darren S.
    Manwell, Stuart E. E.
    Ferreira, Louis M.
    Goel, Danny P.
    Faber, Kenneth J.
    Johnson, James A.
    JOURNAL OF ORTHOPAEDIC TRAUMA, 2011, 25 (01) : 39 - 43
  • [27] Structure analysis of high resolution magnetic resonance Imaging of the proximal femur:: In vitro correlation with biomechanical strength and BMD
    Link, TM
    Vieth, V
    Langenberg, R
    Meier, N
    Lotter, A
    Newitt, D
    Majumdar, S
    CALCIFIED TISSUE INTERNATIONAL, 2003, 72 (02) : 156 - 165
  • [28] Biomechanical Analysis of Conventional Partially Threaded Screws Versus Headless Compression Screws in Proximal Fifth Metatarsal (Jones) Fracture Fixation
    Lam, Kenrick
    Bui, Roger
    Morris, Randal
    Panchbhavi, Vinod
    FOOT & ANKLE SPECIALIST, 2021, 14 (06) : 509 - 514
  • [29] Biomechanical evaluation of a new fixation technique for internal fixation of three-part proximal humerus fractures in a novel cadaveric model
    Brianza, Stefano
    Plecko, Michael
    Gueorguiev, Boyko
    Windolf, Markus
    Schwieger, Karsten
    CLINICAL BIOMECHANICS, 2010, 25 (09) : 886 - 892
  • [30] A Biomechanical Study of Tuberosity-Based Locked Plate Fixation Compared with Standard Proximal Humeral Locking Plate Fixation for 3-Part Proximal Humeral Fractures
    Walker, Robert
    Castaneda, Paulo
    Putnam, Jill G.
    Schemitsch, Emil H.
    McKee, Michael D.
    JOURNAL OF ORTHOPAEDIC TRAUMA, 2020, 34 (07) : E233 - E238