In vitro Biomechanical Analysis of Proximal Phalangeal Osteotomy Fixation

被引:2
作者
Deschuyffeleer, Sten [1 ]
Duerinckx, Joris [1 ]
Caekebeke, Pieter [1 ]
机构
[1] Ziekenhuis Oost Limburg, Dept Orthopaed Surg & Traumatol, Limburg, Belgium
关键词
corrective osteotomy; proximal; phalanx; intramedullary screw; plate; FRACTURES;
D O I
10.1055/s-0040-1721409
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background Corrective osteotomies of the proximal phalanx are typically stabilized with plate and screws. Although intramedullary headless screws form an alternative fixation method in the treatment of acute phalangeal fractures, reports about fixation of opening wedge corrective osteotomies with these implants are lacking. Objective The goal of the present study was to biomechanically compare the failure force of both fixation methods for this specific indication. Methods Twenty-four cadaver phalanges were equally distributed between apex volar and apex lateral opening wedge osteotomy groups. In each group, half of the osteotomies were fixed with a 1.3-mm dorsal locking plate, the other half with a 2.4-mm intramedullary headless screw. A three-point bending test was performed. Results The mean maximal failure force after apex lateral osteotomy was 178.4N for the plate-screw construct and 144.0N after intramedullary headless screw fixation. After apex volar osteotomy, mean maximal force was 237.6N in the plate-screw group and 160.9N in the intramedullary headless screw group. Mean stiffness after apex lateral osteotomy was 63.3N/mm in the plate-screw group, and 55.9N/mm in the intramedullary headless screw group. Mean stiffness after apex volar osteotomy was 197.5N/mm and 60.0N/mm for the plate-screw and intramedullary headless screw group, respectively. Conclusion For apex volar osteotomies, dorsally applied angular stable plate and screws provide significantly stronger fixation than intramedullary headless screws. For apex lateral osteotomies, fixation force is comparable. Clinical relevance These data are useful when considering fixation of opening wedge osteotomies with intramedullary screws.
引用
收藏
页码:154 / 157
页数:4
相关论文
共 50 条
  • [1] Dorsal Plating, Lateral Plating, and Intramedullary Screw Fixation of Extra-Articular Proximal Phalangeal Fractures: A Cadaveric Biomechanical
    Sivakumar, Brahman
    Graham, David J.
    Clarke, Elizabeth
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2024, 49 (03): : 247 - 252
  • [2] Distal Metaphyseal Ulnar Shortening Osteotomy Fixation: A Biomechanical Analysis
    Frey, Christopher S.
    Zhou, Joanne Y.
    Shah, Kalpit N.
    Chan, Calvin K.
    Joseph, Lauren
    Storaci, Hunter
    Segovia, Nicole
    Yao, Jeffrey
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2024, 49 (09): : 928e1 - 928e7
  • [3] Fixation methods in sagittal split ramus osteotomy: a systematic review on in vitro biomechanical assessments
    Kuik, K.
    De Ruiter, M. H. T.
    De Lange, J.
    Hoekema, A.
    INTERNATIONAL JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2019, 48 (01) : 56 - 70
  • [4] Biomechanical analysis of proximal humeral fixation using locking plate fixation with an intramedullary fibular allograft
    Mathison, Craig
    Chaudhary, Rey
    Beaupre, Lauren
    Reynolds, Mathew
    Adeeb, Samer
    Bouliane, Martin
    CLINICAL BIOMECHANICS, 2010, 25 (07) : 642 - 646
  • [5] Intramedullary Screw Fixation of Proximal Phalangeal Fractures: Short- to Medium-term Outcomes
    Abbot, Hagen
    George, Adam R.
    Mccarron, Luke
    Graham, David J.
    Sivakumar, Brahman
    HAND-AMERICAN ASSOCIATION FOR HAND SURGERY, 2024,
  • [6] Outcome Analysis of Metacarpal and Phalangeal Fixation Techniques at Bellevue Hospital
    Reformat, Derek Daniel
    Nores, Gabriela Garcia
    Lam, Gretl
    Cuzzone, Daniel
    Hill, John Bradford
    Muresan, Horatiu
    Thanik, Vishal
    ANNALS OF PLASTIC SURGERY, 2018, 81 (04) : 407 - 410
  • [7] Biomechanical evaluation of three different fixation methods of the Chevron osteotomy of the olecranon: An analysis with Roentgen Stereophotogrammatic Analysis
    Wagener, Marc L.
    Driesprong, Marco
    Heesterbeek, Petra J. C.
    Verdonschot, Nico
    Eygendaal, Denise
    CLINICAL BIOMECHANICS, 2013, 28 (07) : 752 - 756
  • [8] Evaluation of Different Fixation Methods Combinations After L-Shaped Osteotomy Reduction Malarplasty: An In Vitro Biomechanical Study
    Al-Watary, Mohammed Qasem
    Hao, Jiansuo
    He, Yingyou
    Song, Libin
    Gao, Heyou
    Alkebsi, Khaled
    Elayah, Saddam Ahmed
    Ye, Bin
    Li, Jihua
    AESTHETIC PLASTIC SURGERY, 2024, 48 (16) : 3170 - 3179
  • [9] Outcomes Following Open Reduction and Internal Fixation in Proximal Phalangeal Fracture with Rotational Malalignment
    Lee, Jun-Ku
    Hong, In-Tae
    Cho, Jin Woo
    Ha, Cheungsoo
    Yu, Woo-Jin
    Han, Soo-Hong
    JOURNAL OF HAND SURGERY-ASIAN-PACIFIC VOLUME, 2020, 25 (02) : 219 - 225
  • [10] TRANSVERSE FRACTURE OF METACARPAL AND PROXIMAL PHALANGEAL SHAFT FRACTURES OF THE HAND TREATED BY THETA FIXATION
    Ghodke, Ashok
    Vieira, Alfven
    Jain, Vicky
    Vanjari, Rahul
    Dua, Apoorva
    JOURNAL OF EVOLUTION OF MEDICAL AND DENTAL SCIENCES-JEMDS, 2016, 5 (01): : 82 - 86