A comparison of femoral component rotation after total knee arthroplasty in Kanekasu radiographs, axial CT slices and 3D reconstructed images

被引:5
作者
Robertson, Emma L. [1 ,2 ]
Hengherr, Martin [3 ]
Amsler, Felix [4 ]
Hirschmann, Michael T. [1 ,2 ]
Mathis, Dominic T. [1 ,2 ]
机构
[1] Kantonsspital Baselland Bruderholz, Dept Orthopaed Surg & Traumatol, CH-4101 Bruderholz, Switzerland
[2] Univ Basel, CH-4051 Basel, Switzerland
[3] Kantonsspital Baselland Bruderholz, Dept Radiol, CH-4101 Bruderholz, Switzerland
[4] Amsler Consulting, CH-4059 Basel, Switzerland
关键词
Total knee arthroplasty; Rotational alignment; 2D computer tomography; Kanekasu; Reliability; Prediction; CLINICAL TRANSEPICONDYLAR AXIS; COMPUTED-TOMOGRAPHY; PATELLAR TRACKING; DISTAL FEMUR; ALIGNMENT; MALALIGNMENT; REPLACEMENT; MALROTATION; POSITION; LINE;
D O I
10.1007/s00256-020-03702-7
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Objective To compare the posterior condylar angle measured with Kanekasu radiograph and 2D-CT with the gold standard 3D-CT following primary total knee arthroplasty (TKA). Methods Eighty-two knees with pain following TKA were included in this retrospective study. Two independent raters measured the anatomical and surgical posterior condylar angles twice on each Kanekasu radiograph and 2D-CT. These measurements were compared against the 3D-CT measurement. The intra- and interrater reliability of the Kanekasu radiograph and 2D-CT and the correlation with 3D-CT were calculated. Results The intra- and interrater reliability for measurements of the anatomical posterior condyle angle for the Kanekasu radiograph and the 2D-CT were excellent for both raters (0.85-0.92). For the less experienced rater 1, the intrarater reliability was significantly better for 2D-CT than Kanekasu radiograph for measuring both the surgical (p < 0.01) and anatomical posterior condyle angles (p < 0.05). For the experienced rater 2, the intrarater reliability was significantly better for Kanekasu radiograph than 2D-CT for measurement of the surgical posterior condyle angle (p < 0.05). The correlation with 3D-CT is higher in 2D-CT than in Kanekasu radiograph (p < 0.01). While the Kanekasu radiograph predicts the 3D-CT angle with 65.9%, 2D-CT can measure the true angle with 82.9% certainty. Conclusion Measurements using the anatomical transepicondylar axis are easier to replicate compared to the surgical transepicondylar axis. In comparison with the gold standard 3D-CT, 2D-CT showed a significantly higher correlation with 3D-CT than the Kanekasu measurements. If 3D-CT is available, it should be preferred over 2D-CT and Kanekasu view radiograph for femoral component rotation measurements.
引用
收藏
页码:1389 / 1397
页数:9
相关论文
共 50 条
[41]   3D templating and patient-specific cutting guides (Knee-Plan®) in total knee arthroplasty: Postoperative CT-based assessment of implant positioning [J].
Franceschi, J. -P. ;
Sbihi, A. .
ORTHOPAEDICS & TRAUMATOLOGY-SURGERY & RESEARCH, 2014, 100 (06) :S281-S286
[42]   Patient-specific instrumentation improved axial alignment of the femoral component, operative time and perioperative blood loss after total knee arthroplasty [J].
Song Gong ;
Weihua Xu ;
Ruoyu Wang ;
Zijian Wang ;
Bo Wang ;
Lizhi Han ;
Guo Chen .
Knee Surgery, Sports Traumatology, Arthroscopy, 2019, 27 :1083-1095
[43]   A method for reconstructing 3D patient-specific total knee arthroplasty tibia models from 2D bi-planar radiographs [J].
Gothard, Andrew T. ;
Anton, Steven R. .
BIOMEDICAL SIGNAL PROCESSING AND CONTROL, 2025, 99
[44]   4D-SPECT/CT in orthopaedics: a new method of combined quantitative volumetric 3D analysis of SPECT/CT tracer uptake and component position measurements in patients after total knee arthroplasty [J].
Helmut Rasch ;
Anna L. Falkowski ;
Flavio Forrer ;
Johann Henckel ;
Michael T. Hirschmann .
Skeletal Radiology, 2013, 42 :1215-1223
[45]   3D preoperative plan assisted total knee arthroplasty after knee arthrodesis with patella absence: a case report [J].
Liu, Li-Ming ;
Lei, Kai ;
Yang, Peng-Fei ;
Guo, Lin .
BMC MUSCULOSKELETAL DISORDERS, 2024, 25 (01)
[46]   Could surgical transepicondylar axis be identified accurately in preoperative 3D planning for total knee arthroplasty? A reproducibility study based on 3D-CT [J].
Lei, Kai ;
Liu, Li Ming ;
Luo, Jiang Ming ;
Ma, Chao ;
Feng, Qing ;
Yang, Liu ;
Guo, Lin .
ARTHROPLASTY, 2022, 4 (01)
[47]   Lateral shift of the femoral condyle after total knee arthroplasty: simulation using 2D-templates of the medial pivot design on knee radiographs of young Japanese patients [J].
Arata Nakajima ;
Masato Sonobe ;
Yorikazu Akatsu ;
Manabu Yamada ;
Keiichiro Yamamoto ;
Junya Saito ;
Masaki Norimoto ;
Keita Koyama ;
Shinji Taniguchi ;
Hiroshi Takahashi ;
Yasuchika Aoki ;
Toru Suguro ;
Koichi Nakagawa .
Journal of Orthopaedic Surgery and Research, 17
[48]   Does the Robotic Arm and Preoperative CT Planning Help with 3D Intraoperative Total Knee Arthroplasty Planning? [J].
Marchand, Robert C. ;
Sodhi, Nipun ;
Bhowmik-Stoker, Manoshi ;
Scholl, Laura ;
Condrey, Caitlin ;
Khlopas, Anton ;
Sultan, Assem A. ;
Newman, Jared M. ;
Mont, Michael A. .
JOURNAL OF KNEE SURGERY, 2019, 32 (08) :742-749
[49]   An accelerometer-based portable navigation system improved prosthetic alignment after total knee arthroplasty in 3D measurements [J].
Hideki Ueyama ;
Yukihide Minoda ;
Ryo Sugama ;
Yoichi Ohta ;
Kazumasa Yamamura ;
Suguru Nakamura ;
Susumu Takemura ;
Hiroaki Nakamura .
Knee Surgery, Sports Traumatology, Arthroscopy, 2019, 27 :1580-1586
[50]   AI-Assisted 3D Planning of CT Parameters for Personalized Femoral Prosthesis Selection in Total Hip Arthroplasty [J].
Yang, Tian-Jiao ;
Qian, Wei .
THERAPEUTICS AND CLINICAL RISK MANAGEMENT, 2025, 21 :905-916