A comparison of femoral component rotation after total knee arthroplasty in Kanekasu radiographs, axial CT slices and 3D reconstructed images

被引:5
作者
Robertson, Emma L. [1 ,2 ]
Hengherr, Martin [3 ]
Amsler, Felix [4 ]
Hirschmann, Michael T. [1 ,2 ]
Mathis, Dominic T. [1 ,2 ]
机构
[1] Kantonsspital Baselland Bruderholz, Dept Orthopaed Surg & Traumatol, CH-4101 Bruderholz, Switzerland
[2] Univ Basel, CH-4051 Basel, Switzerland
[3] Kantonsspital Baselland Bruderholz, Dept Radiol, CH-4101 Bruderholz, Switzerland
[4] Amsler Consulting, CH-4059 Basel, Switzerland
关键词
Total knee arthroplasty; Rotational alignment; 2D computer tomography; Kanekasu; Reliability; Prediction; CLINICAL TRANSEPICONDYLAR AXIS; COMPUTED-TOMOGRAPHY; PATELLAR TRACKING; DISTAL FEMUR; ALIGNMENT; MALALIGNMENT; REPLACEMENT; MALROTATION; POSITION; LINE;
D O I
10.1007/s00256-020-03702-7
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Objective To compare the posterior condylar angle measured with Kanekasu radiograph and 2D-CT with the gold standard 3D-CT following primary total knee arthroplasty (TKA). Methods Eighty-two knees with pain following TKA were included in this retrospective study. Two independent raters measured the anatomical and surgical posterior condylar angles twice on each Kanekasu radiograph and 2D-CT. These measurements were compared against the 3D-CT measurement. The intra- and interrater reliability of the Kanekasu radiograph and 2D-CT and the correlation with 3D-CT were calculated. Results The intra- and interrater reliability for measurements of the anatomical posterior condyle angle for the Kanekasu radiograph and the 2D-CT were excellent for both raters (0.85-0.92). For the less experienced rater 1, the intrarater reliability was significantly better for 2D-CT than Kanekasu radiograph for measuring both the surgical (p < 0.01) and anatomical posterior condyle angles (p < 0.05). For the experienced rater 2, the intrarater reliability was significantly better for Kanekasu radiograph than 2D-CT for measurement of the surgical posterior condyle angle (p < 0.05). The correlation with 3D-CT is higher in 2D-CT than in Kanekasu radiograph (p < 0.01). While the Kanekasu radiograph predicts the 3D-CT angle with 65.9%, 2D-CT can measure the true angle with 82.9% certainty. Conclusion Measurements using the anatomical transepicondylar axis are easier to replicate compared to the surgical transepicondylar axis. In comparison with the gold standard 3D-CT, 2D-CT showed a significantly higher correlation with 3D-CT than the Kanekasu measurements. If 3D-CT is available, it should be preferred over 2D-CT and Kanekasu view radiograph for femoral component rotation measurements.
引用
收藏
页码:1389 / 1397
页数:9
相关论文
共 50 条
[31]   Comparison of 3D Printing Technology and Artificial Intelligence Assisted in Total Knee Arthroplasty [J].
Pan, Jingbo ;
Zhang, Qi ;
Kong, Gang ;
Liu, Dan ;
Sun, Xiujiang ;
Zhang, Guodong ;
Zou, Yue ;
Liu, Kegui .
INTERNATIONAL JOURNAL OF CLINICAL PRACTICE, 2025, 2025 (01)
[32]   A patient-specific 3D model of the knee to compare the femoral rollback before and after total knee arthroplasty (TKA) [J].
Alexandra Mercader ;
Timon Röttinger ;
Amir Bigdeli ;
Tim C. Lüth ;
Heinz Röttinger .
Journal of Experimental Orthopaedics, 8
[33]   Metal Artifact Reduction Dual-Energy CT as an Accurate and Reliable Method for Measuring Total Knee Arthroplasty Femoral Component Rotation Compared to Conventional CT [J].
Park, Chankue ;
Lee, Sang-Min ;
Seo, Jae Seung ;
Kim, Tae Woo ;
Rhee, Seung Joon ;
Jeong, Hee Seok .
JOURNAL OF KNEE SURGERY, 2023, 36 (09) :988-994
[34]   Comparison of Femoral Component Rotation between Robotic-Assisted vs. Soft-Tissue Tensor Total Knee Arthroplasty with Anatomic Implants [J].
Maciag, Bartosz M. M. ;
Kordyaczny, Tomasz ;
Maciag, Grzegorz J. J. ;
Lapinski, Marcin ;
Jegierski, Dawid ;
Swiderek, Jakub ;
Tsitko, Hanna ;
Dorocinska, Monika ;
Zarnovsky, Krystian ;
Swiercz, Maciej ;
Stepinski, Piotr ;
Adamska, Olga ;
Stolarczyk, Artur .
MEDICINA-LITHUANIA, 2023, 59 (05)
[35]   4D-SPECT/CT in orthopaedics: a new method of combined quantitative volumetric 3D analysis of SPECT/CT tracer uptake and component position measurements in patients after total knee arthroplasty [J].
Rasch, Helmut ;
Falkowski, Anna L. ;
Forrer, Flavio ;
Henckel, Johann ;
Hirschmann, Michael T. .
SKELETAL RADIOLOGY, 2013, 42 (09) :1215-1223
[36]   Planning on CT-Based 3D Virtual Models Can Accurately Predict the Component Size for Total Knee Arthroplasty [J].
Leon-Munoz, Vicente J. ;
Lison-Almagro, Alonso J. ;
Lopez-Lopez, Mirian .
JOURNAL OF KNEE SURGERY, 2020, 33 (11) :1128-1131
[37]   Comparison of soft tissue balancing, femoral component rotation, and joint line change between the gap balancing and measured resection techniques in primary total knee arthroplasty: A meta-analysis [J].
Moon, Young-Wan ;
Kim, Hyun-Jung ;
Ahn, Hyeong-Sik ;
Park, Chan-Deok ;
Lee, Dae-Hee .
MEDICINE, 2016, 95 (39)
[38]   Neutral alignment leads to higher knee society scores after total knee arthroplasty in preoperatively non-varus patients: a prospective clinical study using 3D-CT [J].
Slevin, Omer ;
Hirschmann, Anna ;
Schiapparelli, Filippo F. ;
Amsler, Felix ;
Huegli, Rolf W. ;
Hirschmann, Michael T. .
KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2018, 26 (06) :1602-1609
[39]   Chronological Changes in Sagittal Femoral Bowing after Primary Cementless Total Hip Arthroplasty: A Comparative 3D CT Study [J].
Pardo, Francesco ;
La Mattina, Antonino Amedeo ;
Diquattro, Emanuele ;
Lucchini, Stefano ;
Viceconti, Marco ;
Minerba, Andrea ;
Castagnini, Francesco ;
Traina, Francesco .
JOURNAL OF PERSONALIZED MEDICINE, 2023, 13 (12)
[40]   Comparison of analog 2D and digital 3D preoperative templating for predicting implant size in total knee arthroplasty [J].
Kobayashi, Atsushi ;
Ishii, Yoshinori ;
Takeda, Mitsuhiro ;
Noguchi, Hideo ;
Higuchi, Hiroshi ;
Toyabe, Sinichi .
COMPUTER AIDED SURGERY, 2012, 17 (02) :96-101