A comparison of femoral component rotation after total knee arthroplasty in Kanekasu radiographs, axial CT slices and 3D reconstructed images

被引:5
作者
Robertson, Emma L. [1 ,2 ]
Hengherr, Martin [3 ]
Amsler, Felix [4 ]
Hirschmann, Michael T. [1 ,2 ]
Mathis, Dominic T. [1 ,2 ]
机构
[1] Kantonsspital Baselland Bruderholz, Dept Orthopaed Surg & Traumatol, CH-4101 Bruderholz, Switzerland
[2] Univ Basel, CH-4051 Basel, Switzerland
[3] Kantonsspital Baselland Bruderholz, Dept Radiol, CH-4101 Bruderholz, Switzerland
[4] Amsler Consulting, CH-4059 Basel, Switzerland
关键词
Total knee arthroplasty; Rotational alignment; 2D computer tomography; Kanekasu; Reliability; Prediction; CLINICAL TRANSEPICONDYLAR AXIS; COMPUTED-TOMOGRAPHY; PATELLAR TRACKING; DISTAL FEMUR; ALIGNMENT; MALALIGNMENT; REPLACEMENT; MALROTATION; POSITION; LINE;
D O I
10.1007/s00256-020-03702-7
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Objective To compare the posterior condylar angle measured with Kanekasu radiograph and 2D-CT with the gold standard 3D-CT following primary total knee arthroplasty (TKA). Methods Eighty-two knees with pain following TKA were included in this retrospective study. Two independent raters measured the anatomical and surgical posterior condylar angles twice on each Kanekasu radiograph and 2D-CT. These measurements were compared against the 3D-CT measurement. The intra- and interrater reliability of the Kanekasu radiograph and 2D-CT and the correlation with 3D-CT were calculated. Results The intra- and interrater reliability for measurements of the anatomical posterior condyle angle for the Kanekasu radiograph and the 2D-CT were excellent for both raters (0.85-0.92). For the less experienced rater 1, the intrarater reliability was significantly better for 2D-CT than Kanekasu radiograph for measuring both the surgical (p < 0.01) and anatomical posterior condyle angles (p < 0.05). For the experienced rater 2, the intrarater reliability was significantly better for Kanekasu radiograph than 2D-CT for measurement of the surgical posterior condyle angle (p < 0.05). The correlation with 3D-CT is higher in 2D-CT than in Kanekasu radiograph (p < 0.01). While the Kanekasu radiograph predicts the 3D-CT angle with 65.9%, 2D-CT can measure the true angle with 82.9% certainty. Conclusion Measurements using the anatomical transepicondylar axis are easier to replicate compared to the surgical transepicondylar axis. In comparison with the gold standard 3D-CT, 2D-CT showed a significantly higher correlation with 3D-CT than the Kanekasu measurements. If 3D-CT is available, it should be preferred over 2D-CT and Kanekasu view radiograph for femoral component rotation measurements.
引用
收藏
页码:1389 / 1397
页数:9
相关论文
共 50 条
[21]   Analysis of Tibial Component Rotation Following Total Knee Arthroplasty Using 3D High Definition Computed Tomography [J].
Roper, Glade E. ;
Bloemke, Adam D. ;
Roberts, Catherine C. ;
Spangehl, Mark J. ;
Clarke, Henry D. .
JOURNAL OF ARTHROPLASTY, 2013, 28 (08) :106-111
[22]   A patient-specific 3D model of the knee to compare the femoral rollback before and after total knee arthroplasty (TKA) [J].
Mercader, Alexandra ;
Roettinger, Timon ;
Bigdeli, Amir ;
Lueth, Tim C. ;
Roettinger, Heinz .
JOURNAL OF EXPERIMENTAL ORTHOPAEDICS, 2021, 8 (01)
[23]   An accelerometer-based portable navigation system improved prosthetic alignment after total knee arthroplasty in 3D measurements [J].
Ueyama, Hideki ;
Minoda, Yukihide ;
Sugama, Ryo ;
Ohta, Yoichi ;
Yamamura, Kazumasa ;
Nakamura, Suguru ;
Takemura, Susumu ;
Nakamura, Hiroaki .
KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2019, 27 (05) :1580-1586
[24]   Mechanical axis-derived femoral component rotation in extramedullary total knee arthroplasty: a comparison between femoral transverse axis and transepicondylar axis [J].
Jai-Gon Seo ;
Young-Wan Moon ;
Ji-Soon Lim ;
Se-Jun Park ;
Sang-Min Kim .
Knee Surgery, Sports Traumatology, Arthroscopy, 2012, 20 :538-545
[25]   Patient-specific instrumentation improved axial alignment of the femoral component, operative time and perioperative blood loss after total knee arthroplasty [J].
Gong, Song ;
Xu, Weihua ;
Wang, Ruoyu ;
Wang, Zijian ;
Wang, Bo ;
Han, Lizhi ;
Chen, Guo .
KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2019, 27 (04) :1083-1095
[26]   Increased Accuracy in Templating for Total Knee Arthroplasty Using 3D Models Generated from Radiographs [J].
Klag, Elizabeth A. ;
Lizzio, Vincent A. ;
Charters, Michael A. ;
Ayoola, Ayooluwa S. ;
Wesemann, Luke ;
Banka, Trevor R. ;
North, W. Trevor .
JOURNAL OF KNEE SURGERY, 2023, 36 (08) :837-842
[27]   Femoral matched tibia component rotation has little effect on the tibial torsion after total knee arthroplasty [J].
Bae, Ji Hoon ;
Lee, Ja-Woon ;
Kim, Soo-Hyun ;
Kim, Sang-Gyun ;
Jeon, Young-Sik ;
Choi, Jeong Seok .
KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2022, 30 (02) :698-704
[28]   Femoral matched tibia component rotation has little effect on the tibial torsion after total knee arthroplasty [J].
Ji Hoon Bae ;
Ja-Woon Lee ;
Soo-Hyun Kim ;
Sang-Gyun Kim ;
Young-Sik Jeon ;
Jeong Seok Choi .
Knee Surgery, Sports Traumatology, Arthroscopy, 2022, 30 :698-704
[29]   Accurate determination of post-operative 3D component positioning in total knee arthroplasty: the AURORA protocol [J].
Edgar A Wakelin ;
Linda Tran ;
Joshua G Twiggs ;
Willy Theodore ;
Justin P Roe ;
Michael I Solomon ;
Brett A Fritsch ;
Brad P Miles .
Journal of Orthopaedic Surgery and Research, 13
[30]   Lateral shift of the femoral condyle after total knee arthroplasty: simulation using 2D-templates of the medial pivot design on knee radiographs of young Japanese patients [J].
Nakajima, Arata ;
Sonobe, Masato ;
Akatsu, Yorikazu ;
Yamada, Manabu ;
Yamamoto, Keiichiro ;
Saito, Junya ;
Norimoto, Masaki ;
Koyama, Keita ;
Taniguchi, Shinji ;
Takahashi, Hiroshi ;
Aoki, Yasuchika ;
Suguro, Toru ;
Nakagawa, Koichi .
JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2022, 17 (01)