Performance Characteristics of a New Generation Pressure Microsensor for Physiologic Applications

被引:15
作者
Cottler, Patrick S. [1 ]
Karpen, Whitney R. [2 ]
Morrow, Duane A. [2 ]
Kaufman, Kenton R. [2 ]
机构
[1] Luna Innovat Inc, Charlottesville, VA 22903 USA
[2] Mayo Clin, Biomech Lab, Rochester, MN 55906 USA
关键词
Pressure; Fiber-optic sensor; Extrinsic Fabry-Perot interferometric (EFPI); CLINICAL-PRACTICE; DEVICE; BIOCOMPATIBILITY; TRANSDUCER; BIOSENSORS; SENSORS;
D O I
10.1007/s10439-009-9718-x
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
A next generation fiber-optic microsensor based on the extrinsic Fabry-Perot interferometric (EFPI) technique has been developed for pressure measurements. The basic physics governing the operation of these sensors makes them relatively tolerant or immune to the effects of high-temperature, high-EMI, and highly-corrosive environments. This pressure microsensor represents a significant improvement in size and performance over previous generation sensors. To achieve the desired overall size and sensitivity, numerical modeling of diaphragm deflection was incorporated in the design, with the desired dimensions and calculated material properties. With an outer diameter of approximately 250 mu m, a dynamic operating range of over 250 mmHg, and a sampling frequency of 960 Hz, this sensor is ideal for the minimally invasive measurement of physiologic pressures and incorporation in catheter-based instrumentation. Nine individual sensors were calibrated and characterized by comparing the output to a U.S. National Institute of Standards and Technology (NIST) Traceable reference pressure over the range of 0-250 mmHg. The microsensor performance demonstrated accuracy of better than 2% full-scale output, and repeatability, and hysteresis of better than 1% full-scale output. Additionally, fatigue effects on five additional sensors were 0.25% full-scale output after over 10,000 pressure cycles.
引用
收藏
页码:1638 / 1645
页数:8
相关论文
共 26 条
[1]   Evaluating the dynamic performance of a fibre optic pressure microsensor [J].
Chen, SG ;
Pislaru, C ;
Kinnick, RR ;
Morrow, DA ;
Kaufman, KR ;
Greenleaf, JF .
PHYSIOLOGICAL MEASUREMENT, 2005, 26 (04) :N13-N19
[2]   Development of a clinically useful mechanical leech device that promotes flap survival in an animal model of venous-congested skin flaps [J].
Cottler, PS ;
Skalak, TC .
ANNALS OF PLASTIC SURGERY, 2001, 47 (02) :138-147
[3]  
COTTLER PS, 2007, P SPIE, V6433
[4]   A NEW TRANSDUCER-TIPPED FIBER OPTIC CATHETER FOR MEASURING INTRAMUSCULAR PRESSURES [J].
CRENSHAW, AG ;
STYF, JR ;
MUBARAK, SJ ;
HARGENS, AR .
JOURNAL OF ORTHOPAEDIC RESEARCH, 1990, 8 (03) :464-468
[5]   Correlation between active and passive isometric force and intramuscular pressure in the isolated rabbit tibialis anterior muscle [J].
Davis, J ;
Kaufman, KR ;
Lieber, RL .
JOURNAL OF BIOMECHANICS, 2003, 36 (04) :505-512
[6]  
Di Giovanni M., 1982, Flat and corrugated diaphragm design handbook
[7]  
M
[8]  
DUNCAN RG, 2006, P SPIE, V6167
[9]   The Camino intracranial pressure device in clinical practice.: Assessment in a 1000 cases [J].
Gelabert-González, M ;
Ginesta-Galan, V ;
Sernamito-García, R ;
Allut, AG ;
Bandin-Diéguez, J ;
Rumbo, RM .
ACTA NEUROCHIRURGICA, 2006, 148 (04) :435-441
[10]  
HOLLINGSWORTHFRIDLUND P, 1988, HEART LUNG, V17, P111