Damage Assessment of Retrieved Birmingham Monoblock Cups: Is Conversion to Dual-Mobility Head a Viable Revision Option?

被引:2
作者
Gascoyne, Trevor C. [1 ]
Lanting, Brent A. [2 ]
Derksen, Kieran J. [3 ]
Teeter, Matthew G. [2 ]
Turgeon, Thomas R. [4 ,5 ]
机构
[1] Orthopaed Innovat Ctr, Winnipeg, MB, Canada
[2] Univ Hosp, Div Orthoped Surg, London Hlth Sci Ctr, London, ON, Canada
[3] Univ Manitoba, Dept Biosyst Engn, Winnipeg, MB, Canada
[4] Univ Manitoba, Dept Surg, Winnipeg, MB, Canada
[5] Concordia Joint Replacement Grp, Winnipeg, MB, Canada
关键词
total hip arthroplasty; acetabular resurfacing; monoblock cup; retrieval; damage assessment; HIP RESURFACING ARTHROPLASTY; VOLUMETRIC WEAR; SIMULATOR; REPLACEMENTS; DEVICE;
D O I
10.1016/j.arth.2017.10.036
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: A novel revision technique for failed hip resurfacings involves retention of the acetabular cup, if well-fixed, which is mated to dual-mobility (DM) prosthesis in a traditional hip replacement configuration. It is unknown whether existing damage on the retained cup will result in unacceptable wear of the DM prosthesis. Methods: Thirty retrieved Birmingham (Smith & Nephew) monoblock cups were visually scored for damage features and area of coverage. Surface roughness measurements were obtained within each damage feature as well as reference points on each cup. Analysis of prior metal-on-metal wear was also performed to determine the maximum change in diameter of the cup. Results: Scratching and grooving (deep, singular scratches) were the most common damage features. Overall bearing surface roughness was estimated as 0.059 mu m (+/- 0.030 mu m) based on percent area coverage of each damage feature. Dimensional change of the bearing surface was negligible for most cups (18 of 30) but ranged from 0.20 to 0.38 mm for the most severely worn samples (5 of 30). Conclusion: Average surface roughness of the retrieved Birmingham cups was low, suggesting an expected 10%-20% increase in DM prosthesis wear. Similarly, dimensional change of the cup due to prior wear is not believed to significantly affect wear. Our findings support the use of a DM head in appropriate scenarios but suggest caution when applied to younger, more active patients whom may be adversely affected by increased prosthesis wear in the long term. (c) 2017 Elsevier Inc. All rights reserved.
引用
收藏
页码:1242 / 1246
页数:5
相关论文
共 19 条
[1]  
[Anonymous], HIP KNEE ARTHR ANN R
[2]  
[Anonymous], 2012, F203312 ASTM
[3]   Accuracy of Acetabular Component Position in Hip Arthroplasty [J].
Barrack, Robert L. ;
Krempec, Jeffrey A. ;
Clohisy, John C. ;
McDonald, Douglas J. ;
Ricci, William M. ;
Ruh, Erin L. ;
Nunley, Ryan M. .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2013, 95A (19) :1760-1768
[4]   Hip simulator study of the influence of patient activity level on the wear of crosslinked polyethylene under smooth and roughened femoral conditions [J].
Bowsher, JG ;
Shelton, JC .
WEAR, 2001, 250 :167-179
[5]   Clinical failure analysis of contemporary ceramic-on-ceramic total hip replacements [J].
Brandt, Jan-M ;
Gascoyne, Trevor C. ;
Guenther, Leah E. ;
Allen, Andrew ;
Hedden, David R. ;
Turgeon, Thomas R. ;
Bohm, Eric R. .
PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2013, 227 (08) :833-846
[6]   Is the acetabular cup orientation after total hip arthroplasty on a two dimension or three dimension model accurate? [J].
Craiovan, Benjamin ;
Renkawitz, Tobias ;
Weber, Markus ;
Grifka, Joachim ;
Nolte, Lutz ;
Zheng, Guoyan .
INTERNATIONAL ORTHOPAEDICS, 2014, 38 (10) :2009-2015
[7]   Cup inclination angle of greater than 50 degrees increases whole blood concentrations of cobalt and chromium ions after metal-on-metal hip resurfacing [J].
Hart, A. J. ;
Buddhdev, P. ;
Winship, P. ;
Faria, N. ;
Powell, J. J. ;
Skinner, J. A. .
HIP INTERNATIONAL, 2008, 18 (03) :212-219
[8]   In Vivo Femoral Head Damage and Its Effect on Polyethylene Wear [J].
Ito, Hiroshi ;
Maloney, Caitlin M. ;
Crowninshield, Roy D. ;
Clohisy, John C. ;
McDonald, Douglas J. ;
Maloney, William J. .
JOURNAL OF ARTHROPLASTY, 2010, 25 (02) :302-308
[9]  
Kurtz SM, 2016, PDL HANDB SER, P1
[10]   Adverse reaction to metal debris following hip resurfacing THE INFLUENCE OF COMPONENT TYPE, ORIENTATION AND VOLUMETRIC WEAR [J].
Langton, D. J. ;
Joyce, T. J. ;
Jameson, S. S. ;
Lord, J. ;
Van Orsouw, M. ;
Holland, J. P. ;
Nargol, A. V. F. ;
De Smet, K. A. .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2011, 93B (02) :164-171