Determination of lormetazepam and its main metabolite in serum using micellar electrokinetic capillary chromatography with direct injection and ultraviolet absorbance detection

被引:14
作者
Nevado, JJB [1 ]
Peñalvo, GC [1 ]
Calderón, MJP [1 ]
机构
[1] Univ Castilla La Mancha, Dept Analyt Chem & Food Technol, Fac Chem, E-13071 Ciudad Real, Spain
来源
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES | 2002年 / 773卷 / 02期
关键词
lormetazepam; lorazepam;
D O I
10.1016/S1570-0232(02)00139-3
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The use of micellar electrokinetic chromatography for the determination of lormetazepam and its metabolite, lorazepam, in serum samples at a concentration range of therapeutic interest was investigated. The separation was carried out at 30 degreesC and 25 W, using a 15 mM borate-phosphate buffer (pH 8) with 30 mM sodium dodecyl sulfate as the separation electrolyte and 15% methanol as organic modifier. The analyses were carried out in 20 min under these conditions. Detection limits of 0.5 mg 1(-1) were achieved for both benzodiazepines in serum. This method was employed for the quantitative resolution of both drugs (at different concentration ratios) in serum with very good recoveries. (C) 2002 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:151 / 158
页数:8
相关论文
共 25 条
[1]   VALIDATION OF A CAPILLARY ELECTROPHORESIS METHOD FOR THE DETERMINATION OF A QUINOLONE ANTIBIOTIC AND ITS RELATED IMPURITIES [J].
ALTRIA, KD ;
CHANTER, YL .
JOURNAL OF CHROMATOGRAPHY A, 1993, 652 (02) :459-463
[2]   ESSENTIAL PEAK AREA NORMALIZATION FOR QUANTITATIVE IMPURITY CONTENT DETERMINATION BY CAPILLARY ELECTROPHORESIS [J].
ALTRIA, KD .
CHROMATOGRAPHIA, 1993, 35 (3-4) :177-182
[3]  
Baker D. R., 1995, CAPILLARY ELECTROPHO
[4]   SUPPRESSION OF CHIRAL RECOGNITION OF 3-HYDROXY-1,4-BENZODIAZEPINES DURING MICELLAR ELECTROKINETIC CAPILLARY CHROMATOGRAPHY WITH BILE-SALTS [J].
BOONKERD, S ;
DETAEVERNIER, MR ;
MICHOTTE, Y ;
VINDEVOGEL, J .
JOURNAL OF CHROMATOGRAPHY A, 1995, 704 (01) :238-241
[5]  
COUFAL P, 1994, HRC-J HIGH RES CHROM, V17, P325
[6]   Lowering the UV absorbance detection limit in capillary zone electrophoresis using a single linear photodiode array detector [J].
Culbertson, CT ;
Jorgenson, JW .
ANALYTICAL CHEMISTRY, 1998, 70 (13) :2629-2638
[7]  
EVENSON MA, 1992, CLIN CHEM, V38, P1847
[8]   PARAMETERS INFLUENCING SEPARATION AND DETECTION OF ANIONS BY CAPILLARY ELECTROPHORESIS [J].
HARROLD, MP ;
WOJTUSIK, MJ ;
RIVIELLO, J ;
HENSON, P .
JOURNAL OF CHROMATOGRAPHY, 1993, 640 (1-2) :463-471
[9]   DIODE-ARRAY DETECTION IN CAPILLARY ELECTROPHORESIS [J].
HEIGER, DN ;
KALTENBACH, P ;
SIEVERT, HJP .
ELECTROPHORESIS, 1994, 15 (10) :1234-1247
[10]  
HUBER L, 1989, PUBLICATION HEWLETT