Intramolecular Zero-Quantum-Coherence 2D NMR Spectroscopy of Lipids in the Human Breast at 7 T

被引:19
作者
de Graaf, Robin A. [1 ,2 ]
Klomp, Dennis W. J. [1 ]
Luijten, Peter R. [1 ]
Boer, Vincent O. [1 ]
机构
[1] UMC Utrecht, Dept Radiol, Utrecht, Netherlands
[2] Yale Univ, Magnet Resonance Res Ctr, Dept Diagnost Radiol, New Haven, CT 06520 USA
关键词
human breast; unsaturated fatty acids; zero-quantum-coherences; magnetic field inhomogeneity; 7; Tesla; IN-VIVO; PROTON SPECTROSCOPY; ECHOES;
D O I
10.1002/mrm.24701
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PurposeIntramolecular zero-quantum-coherences (ZQCs) are intrinsically insensitive toward magnetic field inhomogeneity. This fact is used to quantify and characterize lipid signals in the human breast at 7 T despite the presence of severe magnetic field inhomogeneity caused by water-lipid susceptibility boundaries. MethodsA novel 3D localized 2D ZQC method is presented. The combination of cardiac/respiratory triggering and post-acquisition navigator echo correction provides high-quality 2D NMR spectra in vivo. ResultsThe lipid profile of the human breast could be quantified by 2D ZQC NMR in 100% of the subjects despite a wide range of magnetic field homogeneity. With conventional 1D H-1 MRS, the magnetic field homogeneity was only adequate in 60% of the subjects. The results from 2D ZQC NMR and 1D NMR are in good correspondence, both in vitro and in vivo. ConclusionIt has been demonstrated that high quality and quantitative 2D ZQC NMR spectra can be acquired from human breast tissue at 7 T. While the simplicity and sensitivity of 1D MRS are preferable when the magnetic field homogeneity is adequate, the 2D ZQC method provides a viable alternative in cases where this requirement cannot be met. Magn Reson Med 71:451-457, 2014. (c) 2013 Wiley Periodicals, Inc.
引用
收藏
页码:451 / 457
页数:7
相关论文
共 15 条
  • [1] 2-DIMENSIONAL SPECTROSCOPY - APPLICATION TO NUCLEAR MAGNETIC-RESONANCE
    AUE, WP
    BARTHOLDI, E
    ERNST, RR
    [J]. JOURNAL OF CHEMICAL PHYSICS, 1976, 64 (05) : 2229 - 2246
  • [2] Spatiotemporal magnetic field monitoring for MR
    Barmet, Christoph
    De Zanche, Nicola
    Pruessmann, Klaas P.
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2008, 60 (01) : 187 - 197
  • [3] Direct B0 field monitoring and real-time B0 field updating in the human breast at 7 tesla
    Boer, Vincent O.
    vd Bank, Bart L.
    van Vliet, Gerard
    Luijten, Peter R.
    Klomp, Dennis W. J.
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2012, 67 (02) : 586 - 591
  • [4] MULTIPLE SPIN ECHOES IN LIQUIDS IN A HIGH MAGNETIC-FIELD
    BOWTELL, R
    BOWLEY, RM
    GLOVER, P
    [J]. JOURNAL OF MAGNETIC RESONANCE, 1990, 88 (03): : 643 - 651
  • [5] In Vivo Brown Adipose Tissue Detection and Characterization Using Water-Lipid Intermolecular Zero-Quantum Coherences
    Branca, Rosa T.
    Warren, Warren S.
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2011, 65 (02) : 313 - 319
  • [6] High resolution NMR spectroscopy of rat brain in vivo through indirect zero-quantum-coherence detection
    de Graaf, Robin A.
    Rothman, Douglas L.
    Behar, Kevin L.
    [J]. JOURNAL OF MAGNETIC RESONANCE, 2007, 187 (02) : 320 - 326
  • [7] NMR MULTIPLE ECHOES OBSERVED IN SOLID HE-3
    DEVILLE, G
    BERNIER, M
    DELRIEUX, JM
    [J]. PHYSICAL REVIEW B, 1979, 19 (11): : 5666 - 5688
  • [8] In vivo determination of human breast fat composition by 1H magnetic resonance spectroscopy at 7 T
    Dimitrov, Ivan E.
    Douglas, Deborah
    Ren, Jimin
    Smith, Nadine B.
    Webb, Andrew G.
    Sherry, A. Dean
    Malloy, Craig R.
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2012, 67 (01) : 20 - 26
  • [9] LOCALIZED PROTON SPECTROSCOPY USING STIMULATED ECHOES
    FRAHM, J
    MERBOLDT, KD
    HANICKE, W
    [J]. JOURNAL OF MAGNETIC RESONANCE, 1987, 72 (03): : 502 - 508
  • [10] INTERMOLECULAR MULTIPLE-QUANTUM COHERENCES AND CROSS CORRELATIONS IN SOLUTION NUCLEAR-MAGNETIC-RESONANCE
    HE, QH
    RICHTER, W
    VATHYAM, S
    WARREN, WS
    [J]. JOURNAL OF CHEMICAL PHYSICS, 1993, 98 (09) : 6779 - 6800