Biomagnetic field detection using very high sensitivity magnetoimpedance sensors for medical applications

被引:65
作者
Uchiyama, Tsuyoshi [1 ]
Nakayama, Shinsuke [2 ]
Mohri, Kaneo [3 ]
Bushida, Kenichi [4 ]
机构
[1] Nagoya Univ, Grad Sch Engn, Dept Elect Engn & Comp Sci, Nagoya, Aichi 4648603, Japan
[2] Nagoya Univ, Grad Sch Med, Dept Cell Physiol, Nagoya, Aichi 4668550, Japan
[3] Nagoya Univ, Aichi Micro Intelligent Co, Tokai, Ibaraki 4768666, Japan
[4] Unitika Co Ltd, Tokyo 103022, Japan
来源
PHYSICA STATUS SOLIDI A-APPLICATIONS AND MATERIALS SCIENCE | 2009年 / 206卷 / 04期
关键词
INTERFERENCE DEVICE MICROSCOPE; AMORPHOUS WIRE;
D O I
10.1002/pssa.200881251
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
This paper demonstrates the performance of magnetoimpedance (MI) sensors for biomagnetic field recording. The rms noise of an amorphous wire MI sensor with 600 turns of pick-up coil was estimated as approximately 3 pT/Hz(1/2) at 1 Hz. Here, we demonstrate that this sensitivity is enough to clearly detect magnetic cardiogram signals. We also measured the biomagnetic field around a smooth muscle tissue sample taken from a guinea-pig. We discovered that the magnetic-field waveform of a small tissue sample is similar to the voltage waveform measured by a microelectrode array in a smooth muscle sheet sample. The results suggest that the localized biomagnetic field generated by smooth muscle cells can be detected by an MI sensor. We concluded that the MI sensor is a promising device for use as a noninvasive tool to test cell activity or function through magnetic-field measurement. (C) 2009 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim
引用
收藏
页码:639 / 643
页数:5
相关论文
共 7 条
[1]   High resolution low-temperature superconductivity superconducting quantum interference device microscope for imaging magnetic fields of samples at room temperatures [J].
Baudenbacher, F ;
Peters, NT ;
Wikswo, JP .
REVIEW OF SCIENTIFIC INSTRUMENTS, 2002, 73 (03) :1247-1254
[2]   High-resolution imaging of cardiac biomagnetic fields using a low-transition-temperature superconducting quantum interference device microscope [J].
Fong, LE ;
Holzer, JR ;
McBride, K ;
Lima, EA ;
Baudenbacher, F ;
Radparvar, M .
APPLIED PHYSICS LETTERS, 2004, 84 (16) :3190-3192
[3]   Amorphous wire and CMOS IC based magneto-impedance sensors - Origin, topics, and future [J].
Mohri, K. ;
Honkura, Y. .
SENSOR LETTERS, 2007, 5 (01) :267-270
[4]   Amorphous wire and CMOS IC-based sensitive micromagnetic sensors utilizing magnetoimpedance (MI) and stress-impedance (SI) effects [J].
Mohri, K ;
Uchiyama, T ;
Shen, LP ;
Cai, CM ;
Panina, LV ;
Honkura, Y ;
Yamamoto, M .
IEEE TRANSACTIONS ON MAGNETICS, 2002, 38 (05) :3063-3068
[5]   Pacemaker phase shift in the absence of neural activity in guinea-pig stomach: a microelectrocle array study [J].
Nakayama, Shinsuke ;
Shimono, Ken ;
Liu, Flong-Nian ;
Jiko, Hideyasu ;
Katayama, Noburu ;
Tomita, Tadao ;
Goto, Kazunori .
JOURNAL OF PHYSIOLOGY-LONDON, 2006, 576 (03) :727-738
[6]  
SANACCI S, 2004, IEEE T MAGN, V40, P3505
[7]   Measurement of the signal from a cultured cell using a high-Tc SQUID [J].
Tanaka, S ;
Tanaka, N ;
Natsume, M ;
Uchida, M ;
Oshita, M ;
Aspanut, Z ;
Eki, T ;
Yoshida, S .
SUPERCONDUCTOR SCIENCE & TECHNOLOGY, 2003, 16 (12) :1536-1539