Improved design of drilled flange (DF) moment resisting connection for seismic regions

被引:12
作者
Jazany, Roohollah Ahmady [1 ]
机构
[1] Islamic Azad Univ, East Tehran Branch, Dept Civil Engn, Emam Reza Blvd, Tehran, Iran
关键词
Center-to-center distance of the holes; Full plastic moment; Holes diameter; Row number of drilled holes; Yield moment; Drilled flange connection; STEELS;
D O I
10.1007/s10518-017-0265-9
中图分类号
P5 [地质学];
学科分类号
0709 ; 081803 ;
摘要
Reduced beam section (RBS) connection was developed as an authentic alternative for welded unreinforced flange connections to prevent the wide spread typical damage of the beam to column welded connections observed after the 1994 Northridge earthquake. Drilled flange (DF) connection, as the next generation of RBS connection, was developed to replace the former RBS connection, due to their easier construction. The present study aims to investigate the effects of different design parameters such as center-to-center distance of the drilled holes, drilled holes diameter, row number of the drilled holes and beam span-to-depth ratio on seismic performance of DF connection. For this purpose, experimentally validated detailed finite element models (FEMs) are used. Also, the cyclic responses of FEMs are utilized to validate the proposed closed-form equations for estimating the yield moment and plastic moment capacity of DF connection. The results indicate that placing the specified limits on the latter design parameters can reduce equivalent plastic strain and Rupture Index at CJP groove weld line of DF connection up to 100 and 154%, respectively. Furthermore, based on the analytical results, the proposed closed-form equations can predict the plastic moment capacity and the yield moment of DF connection with the maximum errors bound less than 8 and 9%, respectively. The results of this study provide the practical recommendations for DF connection seismic design.
引用
收藏
页码:1987 / 2020
页数:34
相关论文
共 40 条
[1]  
AISC, 2015, AISC 341 16
[2]  
[Anonymous], 2016, SPEC STRUCT STEEL BU
[3]  
[Anonymous], REPORT NO SAC BD 98
[4]  
[Anonymous], 2000, REPORT NO FEMA 356
[5]  
[Anonymous], 2016, AISC, P358
[6]  
ANSYS, 1998, USERS MANUAL VERSION
[7]   Optimum drilled flange moment resisting connections for seismic regions [J].
Atashzaban, Ardavan ;
Hajirasouliha, Iman ;
Jazany, Roohollah Ahmady ;
Izadinia, Mohsen .
JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2015, 112 :325-338
[8]  
ATC, 1992, ATC 24
[9]   Promotion of cyclic behavior of reduced beam section connections restraining beam web to local buckling [J].
Deylami, A. ;
Tabar, A. Moslehi .
THIN-WALLED STRUCTURES, 2013, 73 :112-120
[10]  
DIN, 1995, DIN 1025