Polymeric Microchip for the Simultaneous Determination of Anions and Cations by Hydrodynamic Injection Using a Dual-Channel Sequential Injection Microchip Electrophoresis System

被引:39
|
作者
Gaudry, Adam J. [1 ]
Nai, Yi Heng [1 ]
Guij, Rosanne M. [2 ]
Breadmore, Michael C. [1 ]
机构
[1] Univ Tasmania, Fac Sci Engn & Technol, Sch Phys Sci Chem, Australian Ctr Res Separat Sci, Hobart, Tas 7001, Australia
[2] Univ Tasmania, Fac Hlth Sci, Pharm Sch Med, Australian Ctr Res Separat Sci, Hobart, Tas 7001, Australia
基金
澳大利亚研究理事会;
关键词
CONTACTLESS CONDUCTIVITY DETECTION; PRESSURE PULSE INJECTION; CONTINUOUS SAMPLE FLOW; CAPILLARY-ELECTROPHORESIS; MICROFLUIDIC CHIPS; GLASS CHIPS; PLANAR CHIP; SEPARATION; ELECTRODES; DEVICES;
D O I
10.1021/ac403627g
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A dual-channel sequential injection microchip capillary electrophoresis system with pressure-driven injection is demonstrated for simultaneous separations of anions and cations from a single sample. The poly(methyl methacrylate) (PMMA) microchips feature integral in-plane contactless conductivity detection electrodes. A novel, hydrodynamic "split-injection" method utilizes background electrolyte (BGE) sheathing to gate the sample flows, while control over the injection volume is achieved by balancing hydrodynamic resistances using external hydrodynamic resistors. Injection is realized by a unique flow-through interface, allowing for automated, continuous sampling for sequential injection analysis by microchip electrophoresis. The developed system was very robust, with individual microchips used for up to 2000 analyses with lifetimes limited by irreversible blockages of the microchannels. The unique dual-channel geometry was demonstrated by the simultaneous separation of three cations under 40 s with limits of detection (LODs) ranging from 1.5 to 24 mu M. From a series of 100 sequential injections the %RSDs were determined for every fifth run, resulting in %RSDs for migration times that ranged from 0.3 to 0.7 (n = 20) and 2.3 to 4.5 for peak area (n = 20). This system offers low LODs and a high degree of reproducibility and robustness while the hydrodynamic injection eliminates electrokinetic bias during injection, making it attractive for a wide range of rapid, sensitive, and quantitative online analytical applications.
引用
收藏
页码:3380 / 3388
页数:9
相关论文
共 50 条
  • [1] Electrophoretic microchip with dual-opposite injection for simultaneous measurements of anions and cations
    Wang, J
    Chen, G
    Muck, A
    Collins, GE
    ELECTROPHORESIS, 2003, 24 (21) : 3728 - 3734
  • [2] Dual-channel capillary electrophoresis for simultaneous determination of cations and anions
    Opekar, Frantisek
    Tuma, Petr
    JOURNAL OF CHROMATOGRAPHY A, 2016, 1446 : 158 - 163
  • [3] Sequential Determination of Inorganic Cations and Anions in Cerebrospinal Fluid by Microchip Electrophoresis
    Jasna Hradski
    Róbert Bodor
    Marián Masár
    Chromatographia, 2014, 77 : 1461 - 1468
  • [4] Sequential Determination of Inorganic Cations and Anions in Cerebrospinal Fluid by Microchip Electrophoresis
    Hradski, Jasna
    Bodor, Robert
    Masar, Marian
    CHROMATOGRAPHIA, 2014, 77 (21-22) : 1461 - 1468
  • [5] Automated dual capillary electrophoresis system with hydrodynamic injection for the concurrent determination of cations and anions
    Thi Thanh Thuy Pham
    Thanh Duc Mai
    Thanh Dam Nguyen
    Saiz, Jorge
    Hung Viet Pham
    Hauser, Peter C.
    ANALYTICA CHIMICA ACTA, 2014, 841 : 77 - 83
  • [6] Hydrodynamic injection for microchip electrophoresis: Development of an innovative passive system
    Dispas, Amandine
    Emonts, Paul
    Vandormael, Denis
    Bernier, Damien
    Dortu, Fabian
    Ziemons, Eric
    Hubert, Philippe
    Crommen, Jacques
    Fillet, Marianne
    GREEN ANALYTICAL CHEMISTRY, 2024, 10
  • [7] Simultaneous Determination of Inorganic Cations and Anions in Microchip Electrophoresis Using High-voltage Relays
    Zhe Huang
    Mingpeng Yang
    Hui You
    Yang Xie
    Analytical Sciences, 2018, 34 : 801 - 805
  • [8] Simultaneous Determination of Inorganic Cations and Anions in Microchip Electrophoresis Using High-voltage Relays
    Huang, Zhe
    Yang, Mingpeng
    You, Hui
    Xie, Yang
    ANALYTICAL SCIENCES, 2018, 34 (07) : 801 - 805
  • [9] A simple approach to the hydrodynamic injection in microchip electrophoresis with electrochemical detection
    Dossi, Nicolo
    Toniolo, Rosanna
    Susmel, Sabina
    Pizzariello, Andrea
    Bontempelli, Gino
    ELECTROPHORESIS, 2010, 31 (15) : 2541 - 2547
  • [10] Instrumentation design for hydrodynamic sample injection in microchip electrophoresis: A review
    Saito, Renata M.
    Coltro, Wendell K. T.
    de Jesus, Dosil P.
    ELECTROPHORESIS, 2012, 33 (17) : 2614 - 2623