24-Hour Intraocular Pressure Rhythm in Patients With Untreated Primary Open Angle Glaucoma and Effects of Selective Laser Trabeculoplasty

被引:23
作者
Aptel, Florent [1 ,2 ,3 ]
Musson, Cecile [1 ,2 ]
Zhou, Thierry [1 ,2 ]
Lesoin, Antoine [1 ,2 ]
Chiquet, Christophe [1 ,2 ,3 ]
机构
[1] Univ Grenoble Alpes, Grenoble, France
[2] Univ Hosp Grenoble, Dept Ophthalmol, F-38043 Grenoble 09, France
[3] Joseph Fourier Univ, Lab Hypoxia & Physiopathol, INSERM, U1042, Grenoble, France
关键词
intraocular pressure; nyctohemeral rhythm; selective laser trabeculoplasty; CONTACT-LENS SENSOR; HEALTHY-SUBJECTS; PATTERNS; FLUCTUATIONS;
D O I
10.1097/IJG.0000000000000604
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose of the Study:The purpose of the study was to evaluate the 24-hour nyctohemeral rhythm of intraocular pressure (IOP) in patients with untreated primary open angle glaucoma using a contact lens sensor. To evaluate the effect of selective laser trabeculoplasty (SLT) on the 24-hour rhythm of IOP.Materials and Methods:Prospective study conducted in a chronobiology center. Fourteen patients with primary open angle glaucoma underwent three 24-hour IOP measurement sessions after a complete wash-out of the medical treatment: before SLT and 1 and 6 months after, using the contact lens sensor Triggerfish (SENSIMED, Lausanne, Switzerland). IOP and the main parameters of nyctohemeral rhythm (existence of a rhythm, acrophase, bathyphase, midline estimating statistic of rhythm, amplitude, and range) before SLT were compared with the same parameters measured 1 and 6 months later.Results:IOP increased from 16.33.7 to 22.1 +/- 8.4 mm Hg (5.8 mm Hg; 95% confidence interval (CI), 2.41-12.71; P=0.009) after the wash-out procedure. After SLT, IOP significantly decreased by 3.4 mm Hg (95% CI, 0.09-7.89; P=0.041) (14.9%) at 1 month and 1.9 mm Hg (95% CI 0.10-3.84; P=0.044) (8.1%) at 6 months. After medication wash-out, 100% of the subjects had a nyctohemeral IOP rhythm with nocturnal acrophase (01:57 +/- 3:32 am, 01:22 +/- 3:01 am, and 03:17 +/- 2:12 am at inclusion, 1 and 6 mo, respectively). SLT did not significantly change the characteristics of the 24-hour IOP pattern, notably the amplitude and the type of rhythm (persistence of nocturnal acrophase).Conclusions:After medical treatment wash-out, patients with open angle glaucoma consistently had a significant 24-hour IOP rhythm with nocturnal acrophase. SLT reduces the absolute IOP value but does not modify the nyctohemeral IOP rhythm.
引用
收藏
页码:272 / 277
页数:6
相关论文
共 26 条
  • [11] First steps toward noninvasive intraocular pressure monitoring with a sensing contact lens
    Leonardi, M
    Leuenberger, P
    Bertrand, D
    Bertsch, A
    Renaud, P
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2004, 45 (09) : 3113 - 3117
  • [12] Wireless contact lens sensor for intraocular pressure monitoring: assessment on enucleated pig eyes
    Leonardi, Matteo
    Pitchon, Elie M.
    Bertsch, Arnaud
    Renaud, Philippe
    Mermoud, Andre
    [J]. ACTA OPHTHALMOLOGICA, 2009, 87 (04) : 433 - 437
  • [13] Liu J. H., 2015, PLOS ONE, V10
  • [14] Laboratory assessment of diurnal and nocturnal ocular perfusion pressures in humans
    Liu, JHK
    Gokhale, PA
    Loving, RT
    Kripke, DF
    Weinreb, RN
    [J]. JOURNAL OF OCULAR PHARMACOLOGY AND THERAPEUTICS, 2003, 19 (04) : 291 - 297
  • [15] Twenty-four-hour intraocular pressure pattern associated with early glaucomatous changes
    Liu, JHK
    Zhang, XY
    Kripke, DF
    Weinreb, RN
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2003, 44 (04) : 1586 - 1590
  • [16] Intraocular pressure variability in patients who reached target intraocular pressure
    Malerbi, FK
    Hatanaka, M
    Vessani, RM
    Susanna, R
    [J]. BRITISH JOURNAL OF OPHTHALMOLOGY, 2005, 89 (05) : 540 - 542
  • [17] Mansouri K, 2015, PLOS ONE, V10
  • [18] Analysis of Continuous 24-Hour Intraocular Pressure Patterns in Glaucoma
    Mansouri, Kaweh
    Liu, John H. K.
    Weinreb, Robert N.
    Tafreshi, Ali
    Medeiros, Felipe A.
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2012, 53 (13) : 8050 - 8056
  • [19] Mansouri K, 2012, ARCH OPHTHALMOL-CHIC, V130, P1534, DOI [10.1001/archophthalmol.2012.2280, 10.1001/jamaophthalmol.2013.1350]
  • [20] Continuous intraocular pressure monitoring with a wireless ocular telemetry sensor: initial clinical experience in patients with open angle glaucoma
    Mansouri, Kaweh
    Shaarawy, Tarek
    [J]. BRITISH JOURNAL OF OPHTHALMOLOGY, 2011, 95 (05) : 627 - 629