24-Hour Intraocular Pressure Rhythm in Patients With Untreated Primary Open Angle Glaucoma and Effects of Selective Laser Trabeculoplasty

被引:23
作者
Aptel, Florent [1 ,2 ,3 ]
Musson, Cecile [1 ,2 ]
Zhou, Thierry [1 ,2 ]
Lesoin, Antoine [1 ,2 ]
Chiquet, Christophe [1 ,2 ,3 ]
机构
[1] Univ Grenoble Alpes, Grenoble, France
[2] Univ Hosp Grenoble, Dept Ophthalmol, F-38043 Grenoble 09, France
[3] Joseph Fourier Univ, Lab Hypoxia & Physiopathol, INSERM, U1042, Grenoble, France
关键词
intraocular pressure; nyctohemeral rhythm; selective laser trabeculoplasty; CONTACT-LENS SENSOR; HEALTHY-SUBJECTS; PATTERNS; FLUCTUATIONS;
D O I
10.1097/IJG.0000000000000604
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose of the Study:The purpose of the study was to evaluate the 24-hour nyctohemeral rhythm of intraocular pressure (IOP) in patients with untreated primary open angle glaucoma using a contact lens sensor. To evaluate the effect of selective laser trabeculoplasty (SLT) on the 24-hour rhythm of IOP.Materials and Methods:Prospective study conducted in a chronobiology center. Fourteen patients with primary open angle glaucoma underwent three 24-hour IOP measurement sessions after a complete wash-out of the medical treatment: before SLT and 1 and 6 months after, using the contact lens sensor Triggerfish (SENSIMED, Lausanne, Switzerland). IOP and the main parameters of nyctohemeral rhythm (existence of a rhythm, acrophase, bathyphase, midline estimating statistic of rhythm, amplitude, and range) before SLT were compared with the same parameters measured 1 and 6 months later.Results:IOP increased from 16.33.7 to 22.1 +/- 8.4 mm Hg (5.8 mm Hg; 95% confidence interval (CI), 2.41-12.71; P=0.009) after the wash-out procedure. After SLT, IOP significantly decreased by 3.4 mm Hg (95% CI, 0.09-7.89; P=0.041) (14.9%) at 1 month and 1.9 mm Hg (95% CI 0.10-3.84; P=0.044) (8.1%) at 6 months. After medication wash-out, 100% of the subjects had a nyctohemeral IOP rhythm with nocturnal acrophase (01:57 +/- 3:32 am, 01:22 +/- 3:01 am, and 03:17 +/- 2:12 am at inclusion, 1 and 6 mo, respectively). SLT did not significantly change the characteristics of the 24-hour IOP pattern, notably the amplitude and the type of rhythm (persistence of nocturnal acrophase).Conclusions:After medical treatment wash-out, patients with open angle glaucoma consistently had a significant 24-hour IOP rhythm with nocturnal acrophase. SLT reduces the absolute IOP value but does not modify the nyctohemeral IOP rhythm.
引用
收藏
页码:272 / 277
页数:6
相关论文
共 26 条
  • [1] Circadian intraocular pressure patterns in healthy subjects, primary open angle and normal tension glaucoma patients with a contact lens sensor
    Agnifili, Luca
    Mastropasqua, Rodolfo
    Frezzotti, Paolo
    Fasanella, Vincenzo
    Motolese, Ilaria
    Pedrotti, Emilio
    Di Iorio, Angelo
    Mattei, Peter A.
    Motolese, Eduardo
    Mastropasqua, Leonardo
    [J]. ACTA OPHTHALMOLOGICA, 2015, 93 (01) : E14 - E21
  • [2] [Anonymous], 2012, TERMINOLOGY GUIDELIN, P151
  • [3] 24-h monitoring devices and nyctohemeral rhythms of intraocular pressure
    Aptel, Florent
    Weinreb, Robert N.
    Chiquet, Christophe
    Mansouri, Kaweh
    [J]. PROGRESS IN RETINAL AND EYE RESEARCH, 2016, 55 : 108 - 148
  • [4] Hourly Awakening vs Continuous Contact Lens Sensor Measurements of 24-Hour Intraocular Pressure Effect on Sleep Macrostructure and Intraocular Pressure Rhythm
    Aptel, Florent
    Tamisier, Renaud
    Pepin, Jean-Louis
    Mottet, Benjamin
    Hubanova, Ralitsa
    Romanet, Jean-Paul
    Chiquet, Christophe
    [J]. JAMA OPHTHALMOLOGY, 2014, 132 (10) : 1232 - 1238
  • [5] Asrani S, 2000, J GLAUCOMA, V9, P134
  • [6] THE STATISTICAL-ANALYSIS OF CIRCADIAN PHASE AND AMPLITUDE IN CONSTANT-ROUTINE CORE-TEMPERATURE DATA
    BROWN, EN
    CZEISLER, CA
    [J]. JOURNAL OF BIOLOGICAL RHYTHMS, 1992, 7 (03) : 177 - 202
  • [7] Entrainment of the human circadian pacemaker to longer-than-24-h days
    Gronfier, Claude
    Wright, Kenneth P., Jr.
    Kronauer, Richard E.
    Czeisler, Charles A.
    [J]. PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 2007, 104 (21) : 9081 - 9086
  • [8] Evaluation of Continuous 24-Hour Intraocular Pressure Monitoring for Assessment of Prostaglandin-induced Pressure Reduction in Glaucoma
    Hollo, Gabor
    Kothy, Peter
    Vargha, Peter
    [J]. JOURNAL OF GLAUCOMA, 2014, 23 (01) : E6 - E12
  • [9] Effect of overnight wear of the Triggerfish® sensor on corneal thickness measured by Visante® anterior segment optical coherence tomography
    Hubanova, Ralitsa
    Aptel, Florent
    Chiquet, Christophe
    Mottet, Benjamin
    Romanet, Jean-Paul
    [J]. ACTA OPHTHALMOLOGICA, 2014, 92 (02) : E119 - E123
  • [10] Lee J. W., 2014, MEDICINE, V93, P238