An assessment of ozone levels, UV radiation and their occupational health hazard estimation during photocopying operation

被引:44
作者
Singh, Bhupendra Pratap [1 ]
Kumar, Amit [1 ]
Singh, Deepak [1 ]
Punia, Monika [1 ]
Kumar, Krishan [1 ]
Jain, Vinod Kumar [1 ]
机构
[1] Jawaharlal Nehru Univ, Sch Environm Sci, New Delhi 110067, India
关键词
Ozone; UV radiation; Photocopier machine; Standard erythema dose; INDOOR AIR-QUALITY; OUTDOOR; GENOTOXICITY; EMISSIONS; EXPOSURES; POLLUTION; CHILDREN; REMOVAL;
D O I
10.1016/j.jhazmat.2014.04.049
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
This study investigates the levels of ozone concentration along with an ultraviolet (UV) and visible spectral radiation at eight photocopy centers in an academic institute, Delhi. Sampling was done in two types of locations, i.e., basement photocopy centers (BPC) and ground floor photocopy centers (GPC) for 8 h. Measurements of levels of ozone, UN and visible radiation were done by ozone analyzer, UV radiometer and Field spectra instrument, respectively. Results show that the hourly mean concentration of ozone was observed to be in the range of 1.8-10.0 ppb and 5.3-45.8 ppb for BPC and GPC, respectively. In terms UV radiations, energy lies between 5.0 x 10(-3) and 7.0 x 10(-3) mW/cm(2) for ultraviolet A (UVA), 1.0 x 10(-3) and 2.0 x 10(-3) mW/cm(2) for ultraviolet B (UVB) and 6.0 x 10-3 and 8.0 x 10(-3) mW/cm(2) for ultraviolet C (UVC). Correlation between the UV radiations and ozone production observed was statistically insignificant. To know the health hazard occurred to the workers, the standard erythema dose (SED) value was calculated for emitting UV radiation. The SED was estimated to be in the range of 0.02-0.04 and 0.02-0.32 for direct and indirect methods which is less than the guideline prescribed by Commission Internationale del' Eclairage (CIE). In nutshell, person involved in photocopy operation for their livelihood must be trained and should have knowledge for the long term gradual build up health problems due to ozone and UV production from photocopier. The manufactures should be ultimated with the significant ozone production, so that photocopier machine can be redesigned. (C) 2014 Elsevier B.V. All rights reserved.
引用
收藏
页码:55 / 62
页数:8
相关论文
共 45 条
[1]  
[Anonymous], 2009, National Ambient Air Quality Standards
[2]  
[Anonymous], 2002, 352002 HN
[3]   Granulomatous pneumonitis and mediastinal lymphadenopathy due to photocopier toner dust [J].
Armbruster, C ;
Dekan, G ;
Hovorka, A .
LANCET, 1996, 348 (9028) :690-690
[4]  
ASD, 2005, HANDH SPECTR US GUID
[5]  
Ayotamuno M., 2013, INT J SCI ENG RES, V4, P607
[6]  
Bar-Sela S, 2008, ISR MED ASSOC J, V10, P52
[7]  
Brown DB, 2000, PHOTOCHEM PHOTOBIOL, V72, P340, DOI 10.1562/0031-8655(2000)072<0340:CFSAAI>2.0.CO
[8]  
2
[9]   Assessment of pollutant emissions from dry-process photocopiers [J].
Brown, SK .
INDOOR AIR-INTERNATIONAL JOURNAL OF INDOOR AIR QUALITY AND CLIMATE, 1999, 9 (04) :259-267
[10]   Indoor Air Distribution of Nitrogen Dioxide and Ozone in Urban Hospitals [J].
Chen, Hong-Wen ;
Chuang, Chun-Yu ;
Lin, Heng-To .
BULLETIN OF ENVIRONMENTAL CONTAMINATION AND TOXICOLOGY, 2009, 83 (02) :147-150