Imaging cardiac sympathetic innervation with MIBG: linear conversion of the heart-to-mediastinum ratio between different collimators

被引:10
作者
Brumberg, Joachim [1 ,2 ]
Blazhenets, Ganna [3 ]
Schroeter, Nils [4 ]
Frings, Lars [3 ,5 ]
Jost, Wolfgang H. [6 ]
Lapa, Constantin [1 ,2 ]
Meyer, Philipp T. [3 ]
机构
[1] Univ Hosp Wurzburg, Dept Nucl Med, Oberdurrbacher Str 6, D-97080 Wurzburg, Germany
[2] Julius Maximilians Univ, Oberdurrbacher Str 6, D-97080 Wurzburg, Germany
[3] Univ Freiburg, Fac Med, Med Ctr, Dept Nucl Med, Hugstetter Str 55, D-79106 Freiburg, Germany
[4] Univ Freiburg, Fac Med, Med Ctr, Dept Neurol, Breisacher Str 64, D-79106 Freiburg, Germany
[5] Univ Freiburg, Fac Med, Med Ctr, Ctr Geriatr & Gerontol Freiburg, Lehener Str 88, D-79106 Freiburg, Germany
[6] Parkinson Klin Ortenau, Kreuzbergstr 12, D-77709 Wolfach, Germany
关键词
MIBG; Collimator; Heart-to-mediastinum ratio; Linear conversion; SCINTIGRAPHY; DIAGNOSIS; PARKINSONISM; FAILURE;
D O I
10.1186/s40658-019-0250-2
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
BackgroundThe heart-to-mediastinum (H/M) ratio is a commonly used parameter to measure cardiac I-123 metaiodobenzylguanidine (MIBG) uptake. Since the H/M ratio is substantially influenced by the collimator type, we investigated whether an empirical linear conversion of H/M ratios between camera systems with low-energy (LE) and medium-energy (ME) collimator is possible.MethodsWe included 18 patients with parkinsonism who were referred to one of the two participating molecular imaging facilities for the evaluation of cardiac sympathetic innervation by MIBG scintigraphy. Two consecutive planar image datasets were acquired with LE and ME collimators at 4 h after MIBG administration. Linear regression analyses were performed to describe the association between the H/M ratios gained with both collimator settings, and the accuracy of a linear transfer of the H/M ratio between collimators and across centers was assessed using a leave-one-out procedure.ResultsH/M ratios acquired with LE and ME collimators showed a strong linear relationship both within each imaging facility (R-2 = 0.99, p < 0.001 and R-2 = 0.90, p < 0.001) and across centers (H/M-LE = 0.41 x H/M-ME + 0.63, R-2 = 0.97, p < 0.001). A linear conversion of H/M ratios between collimators and across centers was estimated to be very accurate (mean absolute error 0.05 0.04; mean relative absolute error 3.2 +/- 2.6%).Conclusions The present study demonstrates that a simple linear conversion of H/M ratios acquired with different collimators is possible with high accuracy. This should greatly facilitate the exchange of normative data between settings and pooling of data from different institutions.
引用
收藏
页数:7
相关论文
共 17 条
[1]   INTRACLASS CORRELATION COEFFICIENT AS A MEASURE OF RELIABILITY [J].
BARTKO, JJ .
PSYCHOLOGICAL REPORTS, 1966, 19 (01) :3-&
[2]   Reliability of the 123I-mIBG heart/mediastinum ratio: Results of a multicenter test-retest reproducibility study [J].
Bateman, Timothy M. ;
Ananthasubramaniam, Karthikeyan ;
Berman, Daniel S. ;
Gerson, Myron ;
Gropler, Robert ;
Henzlova, Milena ;
Mendoza, Fernando ;
Miyamoto, Michael ;
Shah, Mahesh ;
Weiland, Frederick .
JOURNAL OF NUCLEAR CARDIOLOGY, 2019, 26 (05) :1555-1565
[3]   131I/123I-Metaiodobenzylguanidine (mIBG) scintigraphy: procedure guidelines for tumour imaging [J].
Bombardieri, Emilio ;
Giammarile, Francesco ;
Aktolun, Cumali ;
Baum, Richard P. ;
Delaloye, Angelika Bischof ;
Maffioli, Lorenzo ;
Moncayo, Roy ;
Mortelmans, Luc ;
Pepe, Giovanna ;
Reske, Sven N. ;
Castellani, Maria R. ;
Chiti, Arturo .
EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2010, 37 (12) :2436-2446
[4]   Proposal for standardization of 123I-metaiodobenzylguanidine (MIBG) cardiac sympathetic imaging by the EANM Cardiovascular Committee and the European Council of Nuclear Cardiology [J].
Flotats, Albert ;
Carrio, Ignasi ;
Agostini, Denis ;
Le Guludec, Dominique ;
Marcassa, Claudio ;
Schaffers, Michael ;
Somsen, G. Aernout ;
Unlu, Mustafa ;
Verberne, Hein J. .
EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2010, 37 (09) :1802-1812
[5]   ABNORMAL I-123 METAIODOBENZYLGUANIDINE MYOCARDIAL WASHOUT AND DISTRIBUTION MAY REFLECT MYOCARDIAL ADRENERGIC DERANGEMENT IN PATIENTS WITH CONGESTIVE CARDIOMYOPATHY [J].
HENDERSON, EB ;
KAHN, JK ;
CORBETT, JR ;
JANSEN, DE ;
PIPPIN, JJ ;
KULKARNI, P ;
UGOLINI, V ;
AKERS, MS ;
HANSEN, C ;
BUJA, LM ;
PARKEY, RW ;
WILLERSON, JT .
CIRCULATION, 1988, 78 (05) :1192-1199
[6]   An improved method for estimating the heart-to-mediastinum ratio from cardiac sympathetic nerve imaging with low-energy high-resolution collimators [J].
Inoue, Yusuke ;
Abe, Yutaka ;
Asano, Yuji ;
Kikuchi, Kei ;
Matsunaga, Keiji ;
Iizuka, Takahiro ;
Nishiyama, Kazutoshi .
JOURNAL OF NUCLEAR CARDIOLOGY, 2014, 21 (03) :614-621
[7]   Acquisition Protocols and Correction Methods for Estimation of the Heart-to-Mediastinum Ratio in 123I-Metaiodobenzylguanidine Cardiac Sympathetic Imaging [J].
Inoue, Yusuke ;
Abe, Yutaka ;
Itoh, Yoshihiro ;
Asano, Yuji ;
Kikuchi, Kei ;
Sakamoto, Yutaka ;
Matsunaga, Keiji ;
Ogino, Yutaka ;
Iizuka, Takahiro ;
Mochizuki, Hideki .
JOURNAL OF NUCLEAR MEDICINE, 2013, 54 (05) :707-713
[8]   Myocardial Iodine-123 Meta-Iodobenzylguanidine Imaging and Cardiac Events in Heart Failure Results of the Prospective ADMIRE-HF (AdreView Myocardial Imaging for Risk Evaluation in Heart Failure) Study [J].
Jacobson, Arnold F. ;
Senior, Roxy ;
Cerqueira, Manuel D. ;
Wong, Nathan D. ;
Thomas, Gregory S. ;
Lopez, Victor A. ;
Agostini, Denis ;
Weiland, Fred ;
Chandna, Harish ;
Narula, Jagat .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2010, 55 (20) :2212-2221
[9]   Meta-Analysis of 123I-MIBG Cardiac Scintigraphy for the Diagnosis of Lewy Body-Related Disorders [J].
King, Alisha E. ;
Mintz, Jim ;
Royall, Donald R. .
MOVEMENT DISORDERS, 2011, 26 (07) :1218-1224
[10]   Multicenter cross-calibration of I-123 metaiodobenzylguanidine heart-to-mediastinum ratios to overcome camera-collimator variations [J].
Nakajima, Kenichi ;
Okuda, Koichi ;
Yoshimura, Mana ;
Matsuo, Shinro ;
Wakabayashi, Hiroshi ;
Imanishi, Yasuhiro ;
Kinuya, Seigo .
JOURNAL OF NUCLEAR CARDIOLOGY, 2014, 21 (05) :970-978