Pressure drop and gas holdup in air-water flow in 180° return bends

被引:15
作者
de Oliveira, Pedro M. [1 ]
Barbosa, Jader R., Jr. [1 ]
机构
[1] Univ Fed Santa Catarina, Dept Mech Engn, POLO Res Labs Emerging Technol Cooling & Thermoph, BR-88040900 Florianopolis, SC, Brazil
关键词
Two-phase flow; Return bend; Frictional pressure drop; Gas holdup; Flow visualization; SMALL-DIAMETER TUBES; 2-PHASE FLOW; R-410A; SUBJECT;
D O I
10.1016/j.ijmultiphaseflow.2014.01.005
中图分类号
O3 [力学];
学科分类号
08 ; 0801 ;
摘要
Gas-liquid flows in curved tubes are found in a number of applications, such as heat exchangers and transport pipes. The present work deals with air-water flow in 180 degrees Gas-liquid flows in curved tubes are found in a number of applications, such as heat exchangers and transport pipes. The present work deals with air-water flow in 180 degrees tube bends (curvatures of 6.1, 8.7, and 12.2) that connect two 5-m long 26-mm ID horizontal tubes. The bend lies in the vertical position and the two-phase flow can be set as upward or downward. The straight and curved segments of test section were made from borosilicate glass to enable visual access to the two-phase flow. The behavior of the static pressure upstream and downstream of the bend was measured for a wide range of flow conditions, covering the stratified, intermittent and annular flow patterns. The pressure drop and gas holdup change associated with the bend were measured for both upward and downward flows, enabling the calculation of the frictional, accelarational and gravitational components of the total pressure drop in the bend. The distribution of the phases in the bend was investigated with a high-speed camera, revealing several twophase phenomena responsible for large variations in gas holdup between the inlet and outlet of the bend for both upward and downward flows. An assessment of the prediction methods currently available in the literature showed that correlations for gas holdup in straight tubes give inaccurate predictions of the average gas holdup in the bend for both flow orientations. Frictional pressure drop correlations for gas-liquid flows in return bends also failed to describe with reasonable accuracy the behavior of the experimental data at low gas superficial velocities for both flow orientations. The performance of the correlations improved at high mixture velocities. tube bends (curvatures of 6.1, 8.7, and 12.2) that connect two 5-m long 26-mm ID horizontal tubes. The bend lies in the vertical position and the two-phase flow can be set as upward or downward. The straight and curved segments of test section were made from borosilicate glass to enable visual access to the two-phase flow. The behavior of the static pressure upstream and downstream of the bend was measured for a wide range of flow conditions, covering the stratified, intermittent and annular flow patterns. The pressure drop and gas holdup change associated with the bend were measured for both upward and downward flows, enabling the calculation of the frictional, accelarational and gravitational components of the total pressure drop in the bend. The distribution of the phases in the bend was investigated with a high-speed camera, revealing several two-phase phenomena responsible for large variations in gas holdup between the inlet and outlet of the bend for both upward and downward flows. An assessment of the prediction methods currently available in the literature showed that correlations for gas holdup in straight tubes give inaccurate predictions of the average gas holdup in the bend for both flow orientations. Frictional pressure drop correlations for gas-liquid flows in return bends also failed to describe with reasonable accuracy the behavior of the experimental data at low gas superficial velocities for both flow orientations. The performance of the correlations improved at high mixture velocities. (c) 2014 Elsevier Ltd. All rights reserved.
引用
收藏
页码:83 / 93
页数:11
相关论文
共 33 条
[1]  
Chen I., 2004, INT COMMUN HEAT MASS, V1933, P2
[2]   Two-phase frictional pressure drop measurements in U-type wavy tubes subject to horizontal and vertical arrangements [J].
Chen, Ing Youn ;
Wu, Yu-Shi ;
Liaw, Jane-Sunn ;
Wang, Chi-Chuan .
APPLIED THERMAL ENGINEERING, 2008, 28 (8-9) :847-855
[3]   Measurements and correlations of frictional single-phase and two-phase pressure drops of R-410A flow in small U-type return bends [J].
Chen, IY ;
Wang, CC ;
Lin, SY .
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2004, 47 (10-11) :2241-2249
[4]  
Chexal B., 1991, The Chexal-Lellouche void fraction correlation for generalized applications
[5]  
Chisholm D., 1983, Two-phase flow in pipelines and heat exchangers
[6]  
Coleman H. W., 2009, Uncertainty analysis for uncertainty analysis for engineers, VThird
[7]  
Da Silva Lima R, 2010, HVAC&R RES, V16, P383
[8]  
da Silva M.J., 2008, THESIS TU DRESDEN
[9]   Flow regime based calibration of a capacitive void fraction sensor for small diameter tubes [J].
De Kerpel, K. ;
Ameel, B. ;
T'Joen, C. ;
Caniere, H. ;
De Paepe, M. .
INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2013, 36 (02) :390-401
[10]  
De Kerpel K, 2013, P 8 EXP HEAT TRANSF