Investigation of the properties of hypercrosslinked polystyrene as a stationary phase for high-performance liquid chromatography

被引:97
作者
Penner, NA
Nesterenko, PN
Ilyin, MM
Tsyurupa, MP
Davankov, VA
机构
[1] Moscow MV Lomonosov State Univ, Div Analyt Chem, Moscow 119899, Russia
[2] Russian Acad Sci, Inst Element Organ Cpds, Moscow 117813, Russia
关键词
column liquid chromatography; hypercrosslinked polystyrene; pore-size distribution; retention mechanisms;
D O I
10.1007/BF02493669
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The mechanical rigidity, swelling properties, adsorption selectivity, and chromatographic performance of hypercrosslinked polystyrene (mainly MN-200 or Purosep-200; Purolite, UK) have been studied to evaluate the use of the material as a stationary phase for reversed-phase high-performance liquid chromatography (RPHPLC). By use of inverse size-exclusion chromatography (SEC) this adsorbent, with a high specific surface area of 1500 m(2) g(-1) was found to have a biporous structure with micropores of ca 1-2 nm and macropores ca 100 nm in diameter. The polymer does not change its volume significantly on changing water for organic solvents. The retention increments for methylene and phenyl groups were calculated and indicated that the mechanism of retention on the hypercrosslinked polystyrene involves pi-pi interactions and strong hydrophobic interactions. The column performance of the hypercrosslinked polystyrene was found to be acceptable, with reduced plate height increasing very slowly as the linear velocity of the mobile phase increased to high values (up to 20-45 cm min(-1)). Columns containing hypercrosslinked polystyrene were evaluated for the separation of phenols. dialkyl phthalates, and polyaromatic compounds. On-column preconcentration of trace organic compounds from aqueous media is possible. With smaller particles of hypercrosslinked polystyrene becoming available, this material can be regarded as an alternative to alkylsilica as a hydrolytically stable column-packing material for RPHPLC.
引用
收藏
页码:611 / 620
页数:10
相关论文
共 39 条
[1]   A history of the origin and development of macroporous ion-exchange resins [J].
Abrams, IM ;
Millar, JR .
REACTIVE & FUNCTIONAL POLYMERS, 1997, 35 (1-2) :7-22
[2]   POLYMERIC COLUMNS FOR LIQUID-CHROMATOGRAPHY [J].
BENSON, JR ;
WOO, DJ .
JOURNAL OF CHROMATOGRAPHIC SCIENCE, 1984, 22 (09) :386-399
[3]   MICROPOROUS HYPERCROSSLINKED POLYSTYRENE STYROSORB AS A RESTRICTED ACCESS PACKING IN SAMPLE CLEANUP FOR HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY .1. EVALUATION OF RESTRICTED ACCESS PROPERTIES [J].
BETH, M ;
UNGER, KK ;
TSYURUPA, MP ;
DAVANKOV, VA .
CHROMATOGRAPHIA, 1993, 36 :351-355
[4]   Influence of solvent effects on retention for a porous polymer sorbent in reversed phase liquid chromatography [J].
Bolliet, D ;
Poole, CF .
CHROMATOGRAPHIA, 1997, 46 (7-8) :381-398
[5]   SOLVENT STRENGTH STUDIES ON POLYSTYRENE-DIVINYLBENZENE COLUMNS [J].
BOWERS, LD ;
PEDIGO, S .
JOURNAL OF CHROMATOGRAPHY, 1986, 371 :243-251
[6]  
BRANDRUP I, 1975, POLYM HDB, P337
[7]   Determination of priority phenolic compounds in water and industrial effluents by polymeric liquid-solid extraction cartridges using automated sample preparation with extraction columns and liquid chromatography - Use of liquid-solid extraction cartridges for stabilization of phenols [J].
Castillo, M ;
Puig, D ;
Barcelo, D .
JOURNAL OF CHROMATOGRAPHY A, 1997, 778 (1-2) :301-311
[8]   Evaluation of two new examples of graphitized carbon blacks for use in solid-phase extraction cartridges [J].
Crescenzi, C ;
DiCorcia, A ;
Passariello, G ;
Samperi, R ;
Carou, MIT .
JOURNAL OF CHROMATOGRAPHY A, 1996, 733 (1-2) :41-55
[9]   STRUCTURE AND PROPERTIES OF HYPERCROSSLINKED POLYSTYRENE - THE 1ST REPRESENTATIVE OF A NEW CLASS OF POLYMER NETWORKS [J].
DAVANKOV, VA ;
TSYURUPA, MP .
REACTIVE POLYMERS, 1990, 13 (1-2) :27-42
[10]   SYNTHESIS OF ACCEPTOR BONDED PHASES FOR DONOR-ACCEPTOR LIQUID-CHROMATOGRAPHY [J].
FELIX, G ;
THIENPONT, A ;
DENTRAYGUES, P .
CHROMATOGRAPHIA, 1992, 34 (3-4) :177-181