Response surface based experimental analysis and thermal resistance model of a thermoelectric power generation system

被引:37
作者
Kumar, Abhishek [1 ]
Singh, Kuljeet [1 ,2 ]
Das, Ranjan [1 ]
机构
[1] Indian Inst Technol Ropar, Dept Mech Engn, Rupnagar 140001, Punjab, India
[2] Univ Calgary, Solar Energy & Community Design Lab, Calgary, AB T2P 3B6, Canada
关键词
Thermosyphon; Thermoelectric power; Response surface method; Experiments; Thermal resistance model; 2-PHASE CLOSED THERMOSIPHON; HEAT-TRANSFER; PERFORMANCE ANALYSIS; OPTIMIZATION;
D O I
10.1016/j.applthermaleng.2019.113935
中图分类号
O414.1 [热力学];
学科分类号
摘要
In this work, a response surface analysis is carried out on an experimental setup of a combined two-phase flow thermosyphon and thermoelectric generator (TEG) system. Three-level Box-Behnken response surface method is adopted for the design of experiments, and analysis of variance is carried out to gauge the contribution of operating parameters on various performance parameters. Effects of operating parameters such as working pressure, filling ratio, evaporator length, and evaporator temperature are studied. The performance of the system itself is gauged concerning the maximum power obtained, open circuit voltage and short circuit current. With an increase in vacuum pressure and evaporator temperature, performance parameters are found to increase. However, performance parameters under the influence of filling ratio and evaporator length first decrease and then increase due to uneven variation in evaporation rate of working fluid. Experiments also reveal that the performance of the thermosyphon-assisted TEG system is mainly governed by pressure and evaporator temperature, whereas filling ratio and evaporator length have relatively lesser influence.
引用
收藏
页数:8
相关论文
共 23 条
[1]  
Bird J., 2014, ELECT CIRCUIT THEORY, V5th
[2]   Power output and efficiency of a thermoelectric generator under temperature control [J].
Chen, Wei-Hsin ;
Wu, Po-Hua ;
Wang, Xiao-Dong ;
Lin, Yu-Li .
ENERGY CONVERSION AND MANAGEMENT, 2016, 127 :404-415
[3]  
Fadhl B., 2015, MODELLING THERMAL BE
[4]   Unsteady experimental and numerical analysis of a two-phase closed thermosyphon at different filling ratios [J].
Jafari, Davoud ;
Filippeschi, Sauro ;
Franco, Alessandro ;
Di Marco, Paolo .
EXPERIMENTAL THERMAL AND FLUID SCIENCE, 2017, 81 :164-174
[5]   Boiling and condensation heat transfer of inclined two-phase closed thermosyphon with various filling ratios [J].
Kim, Yeonghwan ;
Shin, Dong Hwan ;
Kim, Jin Sub ;
You, Seung M. ;
Lee, Jungho .
APPLIED THERMAL ENGINEERING, 2018, 145 :328-342
[6]   Inverse prediction and optimization analysis of a solar pond powering a thermoelectric generator [J].
Kumar, Abhishek ;
Singh, Kuljeet ;
Verma, Sunirmit ;
Das, Ranjan .
SOLAR ENERGY, 2018, 169 :658-672
[7]   Comparative analysis of thermoelectric elements optimum geometry between photovoltaic-thermoelectric and solar thermoelectric [J].
Li, Guiqiang ;
Shittu, Samson ;
Ma, Xiaoli ;
Zhao, Xudong .
ENERGY, 2019, 171 :599-610
[8]   A review of solar photovoltaic-thermoelectric hybrid system for electricity generation [J].
Li, Guiqiang ;
Shittu, Samson ;
Diallo, Thierno M. O. ;
Yu, Min ;
Zhao, Xudong ;
Ji, Jie .
ENERGY, 2018, 158 :41-58
[9]   Performance analysis on a novel micro-channel heat pipe evacuated tube solar collector-incorporated thermoelectric generation [J].
Li, Guiqiang ;
Ji, Jie ;
Zhang, Gan ;
He, Wei ;
Chen, Xiao ;
Chen, Hongbing .
INTERNATIONAL JOURNAL OF ENERGY RESEARCH, 2016, 40 (15) :2117-2127
[10]   Conceptual development of a novel photovoltaic-thermoelectric system and preliminary economic analysis [J].
Li, Guiqiang ;
Zhao, Xudong ;
Ji, Jie .
ENERGY CONVERSION AND MANAGEMENT, 2016, 126 :935-943