Residual and Dynamic Range of Retinal Nerve Fiber Layer Thickness in Glaucoma: Comparison of Three OCT Platforms

被引:109
作者
Mwanza, Jean-Claude [1 ]
Kim, Hanna Y. [2 ]
Budenz, Donald L. [1 ]
Warren, Joshua L. [3 ]
Margolis, Michael [2 ]
Lawrence, Scott D. [1 ]
Jani, Pooja D. [1 ]
Thompson, Garrett S. [1 ]
Lee, Richard K. [2 ]
机构
[1] Univ N Carolina, Dept Ophthalmol, Chapel Hill, NC USA
[2] Univ Miami, Dept Ophthalmol, Bascom Palmer Eye Inst, Miami, FL USA
[3] Yale Univ, Yale Sch Publ Hlth, Dept Biostat, New Haven, CT USA
关键词
glaucoma; optical coherence tomography; retinal nerve fiber layer; OPTICAL COHERENCE TOMOGRAPHY; WAVELENGTH AUTOMATED PERIMETRY; GANGLION-CELL FUNCTION; VISUAL-FIELD DEFECTS; SIGNAL NORMALIZATION; DOMAIN; PROGRESSION; REPRODUCIBILITY; HEAD;
D O I
10.1167/iovs.15-17248
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE. To estimate visual field (VF) sensitivity at which retinal nerve fiber layer (RNFL) thinning reaches the measurement floor and at which RNFL stops thinning (change points), the dynamic range of RNFL thickness, and the number of steps from normal to RNFL floor among three optical coherence tomography (OCT) devices. METHODS. Glaucomatous patients (n = 58) and healthy subjects (n = 55-60) prospectively underwent VF testing and RNFL thickness measurement with Cirrus, Spectralis, and RTVue. Change points and corresponding RNFL thicknesses were estimated with simple linear regression (SLR) and Bayesian change point (BCP) analyses. The dynamic range and number of steps to RNFL floor were determined. RESULTS. The average VF change points and corresponding residual thickness at the time RNFL stopped thinning were -22.2 dB and 57.0 mu m (Cirrus), -25.3 dB and 49.2 mu m (Spectralis), and -24.6 dB and 64.7 mu m (RTVue). The RNFL dynamic ranges derived from SLR values were wider on Spectralis (52.6 mu m) than on Cirrus (35.4 mu m) and RTVue (35.5 mu m); the corresponding number of steps to reach the RNFL floor were 9.0 on Cirrus, 10.6 on Spectralis, and 8.3 on RTVue. CONCLUSIONS. The relative VF sensitivity at which average RNFL thickness reaches the measurement floor, the residual layer thickness, and RNFL dynamic measurement range differ among the three devices. However, the number of steps from normal to the RNFL thickness floor is comparable.
引用
收藏
页码:6344 / 6351
页数:8
相关论文
共 50 条
  • [21] Evaluation of Retinal Nerve Fiber Layer Progression in Glaucoma A Comparison between the Fast and the Regular Retinal Nerve Fiber Layer Scans
    Leung, Christopher Kai-Shun
    Cheung, Carol Yim-Lui
    Weinreb, Robert Neal
    Liu, Shu
    Ye, Cong
    Lai, Gilda
    Liu, Nancy
    Pang, Chi Pui
    Tse, Kwok Kay
    Lam, Dennis Shun Chiu
    OPHTHALMOLOGY, 2011, 118 (04) : 763 - 767
  • [22] Ability of Stratus OCT to Detect Progressive Retinal Nerve Fiber Layer Atrophy in Glaucoma
    Lee, Eun Ji
    Kim, Tae-Woo
    Park, Ki Ho
    Seong, Mincheol
    Kim, Hyunjoong
    Kim, Dong Myung
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2009, 50 (02) : 662 - 668
  • [23] Analysis of retinal nerve fiber layer birefringence in patients with glaucoma and diabetic retinopathy by polarization sensitive OCT
    Desissaire, Sylvia
    Pollreisz, Andreas
    Sedova, Aleksandra
    Hajdu, Dorottya
    Datlinger, Felix
    Steiner, Stefan
    Vass, Clemens
    Schwarzhans, Florian
    Fischer, Georg
    Pircher, Michael
    Schmidt-Erfurth, Ursula
    Hitzenberger, Christoph K.
    BIOMEDICAL OPTICS EXPRESS, 2020, 11 (10) : 5488 - 5505
  • [24] Comparison of Macular and Retinal Nerve Fiber Layer Thickness in Amblyopic and Fellow Eyes
    Gurez, Ceren
    MEDICAL JOURNAL OF BAKIRKOY, 2021, 17 (01) : 36 - 40
  • [25] Comparison of retinal nerve fiber layer and macular thickness measurements with Stratus OCT and OPKO/OTI OCT devices in healthy subjects
    Ahmet Ozkok
    Julide Canan Umurhan Akkan
    Nevbahar Tamcelik
    Mehmet Erdogan
    Didar Ucar Comlekoglu
    Rengin Yildirim
    International Journal of Ophthalmology, 2015, (01) : 98 - 103
  • [26] Machine learning classifiers for glaucoma diagnosis based on classification of retinal nerve fibre layer thickness parameters measured by Stratus OCT
    Bizios, Dimitrios
    Heijl, Anders
    Hougaard, Jesper Leth
    Bengtsson, Boel
    ACTA OPHTHALMOLOGICA, 2010, 88 (01) : 44 - 52
  • [27] Reproducibility of RTVue retinal nerve fiber layer thickness and optic nerve head measurements in normal and glaucoma eyes
    Li Ji-peng
    Wang Xiao-zhen
    Fu Jing
    Li Shu-ning
    Wang Ning-li
    CHINESE MEDICAL JOURNAL, 2010, 123 (14) : 1898 - 1903
  • [28] The Ability of Macular Parameters and Circumpapillary Retinal Nerve Fiber Layer by Three SD-OCT Instruments to Diagnose Highly Myopic Glaucoma
    Akashi, Azusa
    Kanamori, Akiyasu
    Nakamura, Makoto
    Fujihara, Masashi
    Yamada, Yuko
    Negi, Akira
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2013, 54 (09) : 6025 - 6032
  • [29] Evaluation of retinal nerve fiber layer thickness and choroidal thickness in pseudoexfoliative glaucoma and pseudoexfoliative syndrome
    Ozge, Gokhan
    Koylu, Mehmet Talay
    Mumcuoglu, Tarkan
    Gundogan, Fatih Cakir
    Ozgonul, Cem
    Ayyildiz, Onder
    Kucukevcilioglu, Murat
    POSTGRADUATE MEDICINE, 2016, 128 (04) : 444 - 448
  • [30] Comparison of Ganglion Cell and Retinal Nerve Fiber Layer Thickness in Pigment Dispersion Syndrome, Pigmentary Glaucoma, and Healthy Subjects with Spectral-domain OCT
    Arifoglu, Hasan Basri
    Simavli, Huseyin
    Midillioglu, Inci
    Ergun, Sule Berk
    Simsek, Saban
    SEMINARS IN OPHTHALMOLOGY, 2017, 32 (02) : 204 - 209