Residual and Dynamic Range of Retinal Nerve Fiber Layer Thickness in Glaucoma: Comparison of Three OCT Platforms

被引:109
作者
Mwanza, Jean-Claude [1 ]
Kim, Hanna Y. [2 ]
Budenz, Donald L. [1 ]
Warren, Joshua L. [3 ]
Margolis, Michael [2 ]
Lawrence, Scott D. [1 ]
Jani, Pooja D. [1 ]
Thompson, Garrett S. [1 ]
Lee, Richard K. [2 ]
机构
[1] Univ N Carolina, Dept Ophthalmol, Chapel Hill, NC USA
[2] Univ Miami, Dept Ophthalmol, Bascom Palmer Eye Inst, Miami, FL USA
[3] Yale Univ, Yale Sch Publ Hlth, Dept Biostat, New Haven, CT USA
关键词
glaucoma; optical coherence tomography; retinal nerve fiber layer; OPTICAL COHERENCE TOMOGRAPHY; WAVELENGTH AUTOMATED PERIMETRY; GANGLION-CELL FUNCTION; VISUAL-FIELD DEFECTS; SIGNAL NORMALIZATION; DOMAIN; PROGRESSION; REPRODUCIBILITY; HEAD;
D O I
10.1167/iovs.15-17248
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE. To estimate visual field (VF) sensitivity at which retinal nerve fiber layer (RNFL) thinning reaches the measurement floor and at which RNFL stops thinning (change points), the dynamic range of RNFL thickness, and the number of steps from normal to RNFL floor among three optical coherence tomography (OCT) devices. METHODS. Glaucomatous patients (n = 58) and healthy subjects (n = 55-60) prospectively underwent VF testing and RNFL thickness measurement with Cirrus, Spectralis, and RTVue. Change points and corresponding RNFL thicknesses were estimated with simple linear regression (SLR) and Bayesian change point (BCP) analyses. The dynamic range and number of steps to RNFL floor were determined. RESULTS. The average VF change points and corresponding residual thickness at the time RNFL stopped thinning were -22.2 dB and 57.0 mu m (Cirrus), -25.3 dB and 49.2 mu m (Spectralis), and -24.6 dB and 64.7 mu m (RTVue). The RNFL dynamic ranges derived from SLR values were wider on Spectralis (52.6 mu m) than on Cirrus (35.4 mu m) and RTVue (35.5 mu m); the corresponding number of steps to reach the RNFL floor were 9.0 on Cirrus, 10.6 on Spectralis, and 8.3 on RTVue. CONCLUSIONS. The relative VF sensitivity at which average RNFL thickness reaches the measurement floor, the residual layer thickness, and RNFL dynamic measurement range differ among the three devices. However, the number of steps from normal to the RNFL thickness floor is comparable.
引用
收藏
页码:6344 / 6351
页数:8
相关论文
共 50 条
  • [1] Retinal Nerve Fiber Layer Thickness in Normals Measured by Spectral Domain OCT
    Bendschneider, Delia
    Tornow, Ralf P.
    Horn, Folkert K.
    Laemmer, Robert
    Roessler, Christopher W.
    Juenemann, Anselm G.
    Kruse, Friedrich E.
    Mardin, Christian Y.
    JOURNAL OF GLAUCOMA, 2010, 19 (07) : 475 - 482
  • [2] The Optimal Diameter for Circumpapillary Retinal Nerve Fiber Layer Thickness Measurement by SD-OCT in Glaucoma
    Heindl, Ludwig M.
    Adler, Werner
    El-Malahi, Ouahiba
    Schaub, Friederike
    Hermann, Manuel M.
    Dietlein, Thomas S.
    Cursiefen, Claus
    Enders, Philip
    JOURNAL OF GLAUCOMA, 2018, 27 (12) : 1086 - 1093
  • [3] Intereye Comparison of Cirrus OCT in Early Glaucoma Diagnosis and Detecting Photographic Retinal Nerve Fiber Layer Abnormalities
    Park, Hae-Young Lopilly
    Shin, Hye-Young
    Yoon, Jae-Yoon
    Jung, Younhea
    Park, Chan Kee
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2015, 56 (03) : 1733 - 1742
  • [4] Retinal Nerve Fiber Layer Progression in Glaucoma A Comparison between Retinal Nerve Fiber Layer Thickness and Retardance
    Xu, Guihua
    Weinreb, Robert N.
    Leung, Christopher K. S.
    OPHTHALMOLOGY, 2013, 120 (12) : 2493 - 2500
  • [5] Macular Inner Plexiform and Retinal Nerve Fiber Layer Thickness in Glaucoma
    Jung, Hyun-Ho
    Sung, Mi-Sun
    Heo, Hwan
    Park, Sang-Woo
    OPTOMETRY AND VISION SCIENCE, 2014, 91 (11) : 1320 - 1327
  • [6] Central Glaucomatous Damage of the Macula Can Be Overlooked by Conventional OCT Retinal Nerve Fiber Layer Thickness Analyses
    Wang, Diane L.
    Raza, Ali S.
    de Moraes, Carlos Gustavo
    Chen, Monica
    Alhadeff, Paula
    Jarukatsetphorn, Ravivarn
    Ritch, Robert
    Hood, Donald C.
    TRANSLATIONAL VISION SCIENCE & TECHNOLOGY, 2015, 4 (06):
  • [7] Comparison of retinal nerve fiber layer and macular thickness measurements with Stratus OCT and OPKO/OTI OCT devices in healthy subjects
    Ozkok, Ahmet
    Akkan, Julide Canan Umurhan
    Tamcelik, Nevbahar
    Erdogan, Mehmet
    Comlekoglu, Didar Ucar
    Yildirim, Rengin
    INTERNATIONAL JOURNAL OF OPHTHALMOLOGY, 2015, 8 (01) : 98 - 103
  • [8] The Relationship Between Retinal Nerve Fiber Layer Thickness and Optic Nerve Head Neuroretinal Rim Tissue in Glaucoma
    Patel, Nimesh B.
    Sullivan-Mee, Michael
    Harwerth, Ronald S.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2014, 55 (10) : 6802 - 6816
  • [9] Comparison of Cirrus OCT and Stratus OCT on the Ability to Detect Localized Retinal Nerve Fiber Layer Defects in Preperimetric Glaucoma
    Jeoung, Jin Wook
    Park, Ki Ho
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2010, 51 (02) : 938 - 945
  • [10] Comparison of Spectralis-OCT, GDxVCC and GDxECC in assessing retinal nerve fiber layer (RNFL) in glaucomatous patients
    Schallenberg, Maurice
    Dekowski, Dirk
    Kremmer, Stephan
    Selbach, J. Michael
    Steuhl, Klaus-Peter
    GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2013, 251 (05) : 1343 - 1353