Modeling conduit choice for valve-sparing aortic root replacement on biomechanics with a 3-dimensional-printed heart simulator

被引:38
作者
Paulsen, Michael J. [1 ]
Kasinpila, Patpilai [1 ]
Imbrie-Moore, Annabel M. [1 ,2 ]
Wang, Hanjay [1 ]
Hironaka, Camille E. [1 ]
Koyano, Tiffany K. [1 ]
Fong, Robyn [1 ]
Chiu, Peter [1 ]
Goldstone, Andrew B. [1 ]
Steele, Amanda N. [1 ,3 ]
Stapleton, Lyndsay M. [1 ,3 ]
Ma, Michael [1 ]
Woo, Y. Joseph [1 ,3 ]
机构
[1] Stanford Univ, Dept Cardiothorac Surg, Falk Cardiovasc Res Bldg CV-235,300 Pasteur Dr, Stanford, CA 94305 USA
[2] Stanford Univ, Dept Mech Engn, Stanford, CA 94305 USA
[3] Stanford Univ, Dept Bioengn, Stanford, CA 94305 USA
基金
美国国家卫生研究院; 美国国家科学基金会;
关键词
aorta; valve-sparing aortic root replacement; valve-sparing surgery; conduit; in vitro modeling; ex vivo modeling; leaflet velocity; coronary blood flow; DAVID I; REIMPLANTATION TECHNIQUE; CLOSING CHARACTERISTICS; MARFAN-SYNDROME; RE-CREATION; GRAFT; FLOW; OPERATION; VALSALVA; STRESS;
D O I
10.1016/j.jtcvs.2018.10.145
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective: The optimal conduit for valve-sparing aortic root replacement is still debated, with several conduit variations available, ranging from straight tubular grafts to Valsalva grafts. Benefits of neosinus reconstruction include enhanced flow profiles and improved hemodynamics. Curiously, however, some clinical data suggest that straight grafts may have greater long-term durability. In this study, we hypothesized that straight tubular grafts may help maintain the native cylindrical position of the aortic valve commissures radially, resulting in preserved leaflet coaptation, reduced stresses, and potentially improved valve performance. Methods: Using 3D printing, a left heart simulator with a valve-sparing root replacement model and a physiologic coronary circulation was constructed. Aortic valves were dissected from fresh porcine hearts and reimplanted into either straight tubular grafts (n = 6) or Valsalva grafts (n = 6). Conduits were mounted into the heart simulator and hemodynamic, echocardiographic, and high-speed videometric data were collected. Results: Hemodynamic parameters and coronary blood flow were similar between straight and Valsalva grafts, although the former were associated with lower regurgitant fractions, less peak intercommissural radial separation, preserved leaflet coaptation, decreased leaflet velocities, and lower relative leaflet forces compared with Valsalva grafts. Conclusions: Valsalva grafts and straight grafts perform equally well in terms of gross hemodyanics and coronary blood flow. Interestingly, however, the biomechanics of these 2 conduits differ considerably, with straight grafts providing increased radial commissural stability and leaflet coaptation. Further investigation into how these parameters influence clinical outcomes is warranted.
引用
收藏
页码:392 / 403
页数:12
相关论文
共 47 条
  • [1] Impact of aortic annular geometry on aortic valve insufficiency: Insights from a preclinical, ex vivo, porcine model
    Al-Atassi, Talal
    Toeg, Hadi Daood
    Jafar, Reza
    Sohmer, Benjamin
    Labrosse, Michel
    Boodhwani, Munir
    [J]. JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2015, 150 (03) : 656 - 663
  • [2] Duration of Systole and Diastole for Hydrodynamic Testing of Prosthetic Heart Valves: Comparison Between ISO 5840 Standards and in vivo Studies
    Bazan, Ovandir
    Ortiz, Jayme Pinto
    [J]. BRAZILIAN JOURNAL OF CARDIOVASCULAR SURGERY, 2016, 31 (02) : 171 - 173
  • [3] FLUID MECHANICS OF AORTIC ROOT WITH APPLICATION TO CORONARY FLOW
    BELLHOUSE, BJ
    BELLHOUSE, FH
    REID, KG
    [J]. NATURE, 1968, 219 (5158) : 1059 - +
  • [4] Dynamic finite element analysis of the aortic root from MRI-derived parameters
    Conti, Carlo A.
    Votta, Emiliano
    Della Corte, Alessandro
    Del Viscovo, Luca
    Bancone, Ciro
    Cotrufo, Maurizio
    Redaelli, Alberto
    [J]. MEDICAL ENGINEERING & PHYSICS, 2010, 32 (02) : 212 - 221
  • [5] Anatomy of the pig heart: comparisons with normal human cardiac structure
    Crick, SJ
    Sheppard, MN
    Ho, SY
    Gepstein, L
    Anderson, RH
    [J]. JOURNAL OF ANATOMY, 1998, 193 : 105 - 119
  • [6] Results of aortic valve-sparing operations
    David, TE
    Armstrong, S
    Ivanov, J
    Feindel, CM
    Omran, A
    Webb, G
    [J]. JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2001, 122 (01) : 39 - 46
  • [7] Sizing and tailoring the Dacron graft for reimplantation of the aortic valve
    David, TE
    [J]. JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2005, 130 (02) : 243 - 244
  • [8] DAVID TE, 1992, J THORAC CARDIOV SUR, V103, P617
  • [9] Reimplantation of the aortic valve at 20 years
    David, Tirone E.
    David, Carolyn M.
    Feindel, Christopher M.
    Manlhiot, Cedric
    [J]. JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2017, 153 (02) : 232 - 238
  • [10] Aortic Valve Sparing in Different Aortic Valve and Aortic Root Conditions
    David, Tirone E.
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2016, 68 (06) : 654 - 664