Site-specific range uncertainties caused by dose calculation algorithms for proton therapy

被引:100
作者
Schuemann, J. [1 ]
Dowdell, S.
Grassberger, C.
Min, C. H.
Paganetti, H.
机构
[1] Massachusetts Gen Hosp, Dept Radiat Oncol, Boston, MA 02114 USA
关键词
proton therapy; range uncertainty; analytical pencil-beam algorithm; range margins; MONTE-CARLO SIMULATIONS; PENCIL BEAM ALGORITHM; CHARGED-PARTICLE RADIOTHERAPY; ENERGY COMPUTED-TOMOGRAPHY; STOPPING POWER RATIOS; REDEFINITION ALGORITHM; RADIATION-THERAPY; TREATMENT PLANS; BRAGG PEAK; CT;
D O I
10.1088/0031-9155/59/15/4007
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The purpose of this study was to assess the possibility of introducing site-specific range margins to replace current generic margins in proton therapy. Further, the goal was to study the potential of reducing margins with current analytical dose calculations methods. For this purpose we investigate the impact of complex patient geometries on the capability of analytical dose calculation algorithms to accurately predict the range of proton fields. Dose distributions predicted by an analytical pencil-beam algorithm were compared with those obtained using Monte Carlo (MC) simulations (TOPAS). A total of 508 passively scattered treatment fields were analyzed for seven disease sites (liver, prostate, breast, medulloblastoma-spine, medulloblastoma-whole brain, lung and head and neck). Voxel-by-voxel comparisons were performed on two-dimensional distal dose surfaces calculated by pencil-beam and MC algorithms to obtain the average range differences and root mean square deviation for each field for the distal position of the 90% dose level (R90) and the 50% dose level (R50). The average dose degradation of the distal falloff region, defined as the distance between the distal position of the 80% and 20% dose levels (R80-R20), was also analyzed. All ranges were calculated in water-equivalent distances. Considering total range uncertainties and uncertainties from dose calculation alone, we were able to deduce site-specific estimations. For liver, prostate and whole brain fields our results demonstrate that a reduction of currently used uncertainty margins is feasible even without introducing MC dose calculations. We recommend range margins of 2.8% + 1.2 mm for liver and prostate treatments and 3.1% + 1.2 mm for whole brain treatments, respectively. On the other hand, current margins seem to be insufficient for some breast, lung and head and neck patients, at least if used generically. If no case specific adjustments are applied, a generic margin of 6.3% + 1.2 mm would be needed for breast, lung and head and neck treatments. We conclude that the currently used generic range uncertainty margins in proton therapy should be redefined site specific and that complex geometries may require a field specific adjustment. Routine verifications of treatment plans using MC simulations are recommended for patients with heterogeneous geometries.
引用
收藏
页码:4007 / 4031
页数:25
相关论文
共 47 条
  • [1] GEANT4-a simulation toolkit
    Agostinelli, S
    Allison, J
    Amako, K
    Apostolakis, J
    Araujo, H
    Arce, P
    Asai, M
    Axen, D
    Banerjee, S
    Barrand, G
    Behner, F
    Bellagamba, L
    Boudreau, J
    Broglia, L
    Brunengo, A
    Burkhardt, H
    Chauvie, S
    Chuma, J
    Chytracek, R
    Cooperman, G
    Cosmo, G
    Degtyarenko, P
    Dell'Acqua, A
    Depaola, G
    Dietrich, D
    Enami, R
    Feliciello, A
    Ferguson, C
    Fesefeldt, H
    Folger, G
    Foppiano, F
    Forti, A
    Garelli, S
    Giani, S
    Giannitrapani, R
    Gibin, D
    Cadenas, JJG
    González, I
    Abril, GG
    Greeniaus, G
    Greiner, W
    Grichine, V
    Grossheim, A
    Guatelli, S
    Gumplinger, P
    Hamatsu, R
    Hashimoto, K
    Hasui, H
    Heikkinen, A
    Howard, A
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2003, 506 (03) : 250 - 303
  • [2] THEORETICAL AND EXPERIMENTAL ASPECTS OF THE ENERGY-LOSS OF RELATIVISTIC HEAVILY IONIZING PARTICLES
    AHLEN, SP
    [J]. REVIEWS OF MODERN PHYSICS, 1980, 52 (01) : 121 - 173
  • [3] Is it necessary to plan with safety margins for actively scanned proton therapy?
    Albertini, F.
    Hug, E. B.
    Lomax, A. J.
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2011, 56 (14) : 4399 - 4413
  • [4] On the clinical spatial resolution achievable with protons and heavier charged particle radiotherapy beams
    Andreo, Pedro
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2009, 54 (11) : N205 - N215
  • [5] [Anonymous], 1993, 49 ICRU
  • [6] Dosimetric accuracy of planning and delivering small proton therapy fields
    Bednarz, Bryan
    Daartz, Juliane
    Paganetti, Harald
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2010, 55 (24) : 7425 - 7438
  • [7] An algorithm to assess the need for clinical Monte Carlo dose calculation for small proton therapy fields based on quantification of tissue heterogeneity
    Bueno, M.
    Paganetti, H.
    Duch, M. A.
    Schuemann, J.
    [J]. MEDICAL PHYSICS, 2013, 40 (08)
  • [8] The influence of CT image noise on proton range calculation in radiotherapy planning
    Chvetsov, Alexei V.
    Paige, Sandra L.
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2010, 55 (06) : N141 - N149
  • [9] Field size dependence of the output factor in passively scattered proton therapy: Influence of range, modulation, air gap, and machine settings
    Daartz, J.
    Engelsman, M.
    Paganetti, Harald
    Bussiere, M. R.
    [J]. MEDICAL PHYSICS, 2009, 36 (07) : 3205 - 3210
  • [10] Application of the pencil-beam redefinition algorithm in heterogeneous media for proton beam therapy
    Egashira, Y.
    Nishio, T.
    Hotta, K.
    Kohno, R.
    Uesaka, M.
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2013, 58 (04) : 1169 - 1184